CS-175-275-575 Series
LCD User Guide

98/482/EC Declaration
(Applies to products that have CE mark attached)
This equipment has been approved in accordance with Council Decision 98/ 82/EC for Pan-European single
terminal connection to the public switched telephone network (PSTN). However, due to differences between
the individual PSTNs provided in different countries, the approval does not, of itself, give an unconditional
assurance of successful operation on every PSTN network termination point.
Aritech is an Interlogix company.
© 2001 Interlogix B.V.
All rights reserved. Interlogix B.V. grants the right to reprint this manual for internal use only.
Interlogix B.V. reserves the right to change information without notice.

3CS-175-275-575 Series • LCD User Guide
Contents
LCD keypad ........................................................... 4
Preparing your syste .......................................... 6
Turning on your syste ......................................... 7
Turning off your syste ........................................ 8
Turning off your syste in case of alar .............. 9
Bypassing (excluding) one or ore zones............ 10
Life safety functions ............................................ 12
Resetting fire detectors ....................................... 13
Changing user codes........................................... 14
Deleting user codes............................................. 15
Setting the keypad tone ..................................... 16
Setting the syste clock ..................................... 17
Viewing zone status ........................................... 19
Viewing alar e ory ...................................... 20
Reading the event log ........................................ 21
Adjusting view/brightness
of the LCD (text display) ..................................... 22
Service essages display .................................... 23
Glossary of ter s ............................................... 26

CS-175-275-575 Series • LCD User Guide 4
LCD keypad
Power (green): When lit, the
system is connected to the mains
power.
Stay: Press to arm perimeter
protection when on the premises.
Bypass: Press to bypass (exclude) a
zone (or zones) in the event of a
zone fault.
Navigation: Press to scroll through
menu on LCD display.
Star: Used to enable certain
functions.
Ready (green): When lit, the
system is ready to be turned on.
ire (red): When lit, the fire zone
has been activated.
LCD display: Messages.
Away: Press to arm complete
system when leaving the premises.
Chime: Press to turn the chime on
and off.

5CS-175-275-575 Series • LCD User Guide
LCD keypad
aPower (green). The power light is on if the system is
connected to the mains and if the battery is okay. The
power light will flash if the system has a low battery condition
or when the battery is not connected. The power light is off if
the mains is cut.
bReady (green). The ready LED is on when the system is
ready to arm, and flashes when the system is ready to
force arm. If the LED is off, the system cannot be armed,
generally because there is a zone fault.
cFire (red). When the fire LED is lit, a fire zone has been
activated. A rapidly flashing fire LED means that there is a
problem with the fire zone.
gStay. This function key part arms your system. Pressing it
disarms all interior zones but leaves the perimeter
protected.
hAway. Press to arm all zones before leaving.
iBypass. Press to bypass (exclude) zones.
jkNavigation keys. These allow you to scroll
through lists and options on the LCD display.
lChime. Press to turn the chime on and off.
@Hash key. Used to access modules and locations.
$Star. Used to access tasks and enter data.

6CS-175-275-575 Series • LCD User Guide
Preparing your system
LCD Message: Your system is NOT ready to be turned on,
doors or windows might be open.
User Action: Use the up/down arrow.
LCD Message: Zone information.
User Action: Press the bypass key if you want to bypass (exclude)
a zone, so you can arm part of your system.
LCD Message: Zone information.
User Action: Press #.
LCD Message: Your system is ready to be turned on.
System Not Ready
For help, press
System Ready
Type code to arm
jor k S
i S
@ S
X Fault
Zone X
X Bypass
Zone X
or
X Fault Bypass
Zone X
X Okay
Zone X
or

7CS-175-275-575 Series • LCD User Guide
Turning on your system
LCD Message: Your system is ready to be turned on.
User Action: For stay mode, push the stay button,
for away mode push the away button.
LCD Message: Your system is either protected
partially or completely.
LCD Message: Your system is ready to be turned on.
User Action: Type your user code for arming.
LCD Message: Your system is turned on.
OPTION 1: Using the function keys (This feature must be programmed by the installer.)
e S
System Ready
Type code to arm
System Armed
All Zones Secure
System Ready
Type code to arm
OPTION 2: Typing your user code
g S h S
System Armed
Zone(s) Bypassed
System Armed
All Zones Secure
or

8CS-175-275-575 Series • LCD User Guide
Turning off your system
LCD Message:Your system is turned on.
User Action: Type your user code to turn off your system.
System Armed
All Zones Secure
e S
System Ready
Type code to arm LCD Message: Your system is ready to be turned on.

9CS-175-275-575 Series • LCD User Guide
Turning off your system in case of alarm
User Action: Type your user code to turn off your system.
LCD Message: The last alarm is shown on the LCD message
for verification.
User Action: Press #to leave this LCD message.
LCD Message: Your system is ready to be turned on.
X Alarm Mem.
Zone X
System Ready
Type code to arm
ALARM Zone X
e S
LCD Message: An alarm has occurred in zone X.
@ S

10CS-175-275-575 Series • LCD User Guide
Bypassing (excluding) one or more zones
LCD Message: Your system is NOT ready to be turned on.
User Action: Use the up/down arrow.
LCD Message: Shows the state of the first zone.
User Action: Use the up/down arrow.
LCD Message: Zone information.
User Action: Press the bypass key to toggle
between ‘Okay’ and ‘Bypass’.
or LCD Message: Zone information.
User Action: Press #to exit this menu.
System Not Ready
For help, press
2 Bypass
Zone 2
@ S
2 Okay
Zone 2
jk S
jk S
i S
1 Okay
Zone 1
2 Okay
Zone 2
2 Bypass
Zone 2
or

11CS-175-275-575 Series • LCD User Guide
Bypassing (excluding) one or more zones (continued)
LCD Message: Your system is ready to be turned on.
User Action: Type your user code to turn on the system.
LCD Message: Your system is turned on,
but zones are bypassed (excluded) and not protected.
System Ready
Type code to arm
e S
System Armed
Zone(s) Bypassed

12CS-175-275-575 Series • LCD User Guide
Life safety functions
You must press and hold the keys for 2 seconds to activate these functions!
&+“S User action: Press keys 1 and 3 together for two seconds.
FIRE. A fire alarm is started and a message is sent
to the central station.
User action: Press keys and 6 together for two seconds.
MEDICAL. A medical alert is sent to the central station.
User action: Press keys 7 and 9 together for two seconds.
A personal attack alert is sent to the central station,
and if programmed the sirens can be heard.
IRE
MEDICAL ‘+§S
PERSONAL
ATTACK
è+çS

13CS-175-275-575 Series • LCD User Guide
Resetting fire detectors
LCD Message: Alarm message after a fire alarm.
User Action: Type your user code to turn the system off.
LCD Message: Your system is turned off, and the fire detector
has been activated.
User Action: Press *7 in order to reset the fire alarm
The smoke detector has been reset. This may take 10 seconds.
The fire LED (red) will turn off.
User Action: Press #
LCD Message: Your system is turned off, and the fire detector
has been reset. The fire LED goes off if all detectors have been reset.
$èS
@S
System Ready
Type code to arm
ALARM
fire alarm
8 Alarm Mem.
fire alarm
System Ready
Type code to arm
e S

14CS-175-275-575 Series • LCD User Guide
Changing user codes
LCD Message: The system is ready to be turned on.
User Action: Press * 5.
LCD Message: The system asks for a master user code.
User Action: Enter your master user code.
LCD Message: Enter the two digit ID for the new or existing user.
User Action: Enter the user ID, for example 18,
or #to cancel operation.
LCD Message: Enter the new code for this user.
User Action: Type the new user code, for example, 65 3.
System Ready
Type code to arm
Enter new code
18 * * * *
§(‘“S
$(S
eS
Please Enter
Your Code
Enter 2 digit ID
&!S or @S

15CS-175-275-575 Series • LCD User Guide
Deleting user codes
LCD Message: The system is ready to be turned on.
User Action: Press * 5.
LCD Message: The system asks for a master user code.
User Action: Enter your master user code.
LCD Message: Enter the two digit ID for the new or existing user.
User Action: Enter the user ID, for example 18,
or #to cancel operation.
User Action: Press Gfour times to delete the current user.
System Ready
Type code to arm
ggggS
$(S
e S
&!S @S
or
Please Enter
Your Code
Enter 2 digit ID

16CS-175-275-575 Series • LCD User Guide
Setting the keypad tone
LCD Message: The system is ready for arming.
User Action: Press * 0.
LCD Message: You will hear the current tone.
User Action: Use up/down arrow to adjust the keypad tone.
User Action: Use #to accept the tone you like.
System Ready
Type code to arm
$à S
jork S
Raise tone
Lower tone
@ S

17CS-175-275-575 Series • LCD User Guide
Setting the system clock
LCD Message: The system is ready to be turned on.
User Action: Press *97.
LCD Message: The system asks for a user code.
User Action: Enter your user code.
System Ready
Type code to arm
$çèS
e S
Please Enter
Your Code

18CS-175-275-575 Series • LCD User Guide
Setting the system clock (continued)
LCD Message: Current date and time are shown.
User Action: Use the up/down arrow to change the hour,then
minutes, day of the week, day of the month, month and year.
User Action: After you have the correct value, press *to move to
the next item in the list.
LCD Message: After selecting the year, the system will bring you
back to the first step.
$ S
System Ready
Type code to arm
jork S
Wed 16:09
29 November 01

19CS-175-275-575 Series • LCD User Guide
Viewing zone status
LCD Message: The system is ready to be turned on.
User Action: Press *and up arrow.
LCD Message: The first zone is shown.
User Action: Use either up or down arrow to scroll.
LCD Message: The second zone is shown.
User Action: Use either up or down arrow to scroll.
LCD Message: The third zone is shown.
User Action: Press #to exit this menu
System Ready
Type code to arm
3 Okay
Front entrance
@ S
$j S
jork S
jork S
1 Okay
Living room
2 Okay
Bed room

20CS-175-275-575 Series • LCD User Guide
Viewing alarm memory
LCD Message: The system is ready to be turned on.
User Action: Press *3.
LCD Message: The first alarm in memory is shown.
User Action: Use either up or down arrow to scroll.
LCD Message: The second alarm in memory is shown.
User Action: Use either up or down arrow to scroll.
LCD Message: The third alarm in memory is shown.
User Action: Press #, to exit this menu.
System Ready
Type code to arm
6 Alarm Mem.
Zone 6
@ S
$“ S
jork S
jork S
3 Alarm Mem.
Zone 3
5 Alarm Mem.
Zone 5
Other manuals for CS-175 Series
1
This manual suits for next models
2
Table of contents
Other Aritech Keypad manuals

Aritech
Aritech ACL805SUW-RDPX Assembly instructions

Aritech
Aritech ATS1155 User manual

Aritech
Aritech CS-175-275-575 Series User manual

Aritech
Aritech ATS1135 Assembly instructions

Aritech
Aritech ACL599 Owner's manual

Aritech
Aritech CS450 User manual

Aritech
Aritech ACL585 Assembly instructions

Aritech
Aritech ATS1136 Assembly instructions

Aritech
Aritech ACL875FL-KP Assembly instructions

Aritech
Aritech ATS4000 User manual