GCAN GC-1502 User manual

GC-1502
2-channel high speed counter module
User manual
Document version V3.04 (2021/3/17)

GC-1502 user manual
Revision History
Version
Date
Reason
V1.00
2015/09/16
Create
V2.01
2015/12/20
Modify device parameters
V3.01
2017/10/22
Add parameters
V3.02
2019/9/29
Reset function upgrade
V3.03
2020/10/27
Modify product picture
V3.04
2021/3/17
Modify the document format

GC-1502 user manual
Contents
1. Introduction ..............................................................................................................4
1.1 Overview ........................................................................................................4
1.2 Properties at a glance ..................................................................................... 4
1.3 Typical application ........................................................................................ 4
2. Installation ............................................................................................................... 5
2.1 Module fixing ................................................................................................ 5
2.2 Wiring method ............................................................................................... 5
2.3 System statusindicator ................................................................................... 7
2.4 Method of use ................................................................................................ 7
2.5 Combined with GCAN- 8000series ...............................................................8
3. Technical Specifications .......................................................................................... 9
4. Disclaimer ..............................................................................................................10
5. Module selection table ........................................................................................... 11
Sales and service ........................................................................................................13

GC-1502 user manual
1. Introduction
1.1 Overview
The GC-1502 module has integrated 2 counter digital input channels,
which acquires digital signals in real-time and transmits them to the GCAN-
PLC coupler. This module can be used with any other GC Series IO module to
capture and process digital data in industrial automation or distributed control
systems.
1.2 Properties at a glance
●2 high speed input channels
●Input pulse voltage:5~30V
●Maximum input current:3mA
●Electrical isolation: 500 V(GC-bus)
●Current consumption:50mA
●32-bitcounter
●No address setting, configuration via bus coupler or controller
●Operating temperature: -40°C ~+85°C
●Size: 100mm*69mm*12mm
1.3 Typical application
●Distributed acquisition system collects digital quantity
●Industrial field acquisition switch quantity

GC-1502 user manual
2. Installation
This chapter will describe the installation method, wiring method,
meaning of the indicator and meaning of the interface of the GC-1502 module.
2.1 Module fixing
The installation method of GC-1502 module as shown in Figure 2.1 and a
flat-blade screwdriver is needed for auxiliary installation.
Figure 2.1 Installation of GC-1502 module
First install the GCAN-PLC on the guide rail and plug the GC-1502 along
GCAN-PLC's right side until the lock is stuck. When remove the GC-1502, the
user need to release the self-locking mechanism by pulling out the orange label.
The GC-1502 module needs to be used with GCAN-PLC-400/510 or GCAN-
8000/8100 series couplers, and can be powered directly through the coupler, so
there is no need for a separate additional power supply.
2.2 Wiring method
The power wiring as shown in figure 2.2. First, use a flat-blade
screwdriver to insert into the square hole, hold the top edge of the metal sheet
in the square hole, and press toward the hole. Then, insert the wire into the hole.
After plugging in, pull out the screwdriver and the wire can be firmly locked in
the hole.

GC-1502 user manual
Figure 2.2 Wiring method of GC-1502 module
Figure 2.3 GC-1502 module terminal definition
The wiring terminal block of GC-1502 module is shown in Figure 2.3. GC-
1502 contains 2 groups of pulse inputs, and can connect to 2 pulse signals at
most. The corresponding serial numbers and definitions of each indicator are
shown in Table 2.1

GC-1502 user manual
No.
Definition
1
Pulse signal 1
2
NC
3
Pulse signal 2
4
NC
5
Signal 1 RST
6
Signal 2 RST
7
NC
8
NC
Table 2.1 GC-1502 module indicator
2.3 System statusindicator
GC-1502 module has no error indicator light. Please judge the status of
GC-1502 module by "IORUN" and "IOERR" indicator lights of the GCAN-
8000 series coupler. If the "IO ERR" indicator of the GCAN-8000 series
coupler is on, please check the installation of the module.
No.
Definition
1
Module power indicator green light always on means the module power
supply is normal, if it is not on, the power supply is abnormal
2
Unused
3
Module power indicator green light always on means the module power
supply is normal, if it is not on, the power supply is abnormal
4
Unused
5
Blinking means that channel 1 has pulse input, and no light means no input
6
Unused
7
Blinking means that channel 1 has pulse input, and no light means no input
8
Unused
Table 2.2
2.4 Method of use
The counter states of the -1502 module are all represented by 4 bytes, and
the total number of bytes is represented by the total number of 4 states, which
are channel 1, count, channel 2 count, channel 1 frequency and channel 2
respectively
For example, when GC-1502 module is connected to PLC-400, four states
can be used as four IO variables and represented by four UDINTs.
Channel1Cnt AT % I0.0: UDINT; Channel2Cnt AT % I4.0: UDINT;

GC-1502 user manual
Channel1Fre AT % I8.0: UDINT; Channel2Fre AT % I12.0: UDINT;
Gc-1502 has two counter channels, INPUT1 and GND1 for the first group,
INPUT2 and GND2 for the second group.
When the pins of RST1 and RST2 of gc-1502 are connected to the high
current, the corresponding counter channel's count value and frequency can be
cleared.
2.5 Combined with GCAN- 8000series
The state of the digital input is represented by two byte
For example: the GCAN-IO-8000 module node number is 1, the channel 1 of
the first GC-1502 module count 28685, and the frequency is 56849Hz, then the
CAN data frame ID sent by the GCAN-IO-8000 module is 0x181, and the data
length ( DLC) is 8. The frame data is 0x0D, 0x70, 0x00, 0x00, 0x11, 0xDE,
0x00, 0x00. The following table lists a common counter status and its
corresponding status data.
GC-1502 status
Channel
1
Status
count
frequency
CAN bus data
0D
70
00
00
11
DE
00
00
Table 2.3

GC-1502 user manual
3. Technical Specifications
Interface characteristics
Number of inputs
2
Pulse voltage
5~30V
Input current (Max.)
3mA
Electrical isolation
500 V(GC-bus/ Signal voltage)
Counter bit
32-bit
Installation position
In sequential order
Power supply
Powered by GCAN-PLC series,
current consumption 50mA
Environmental testing
Operating temperature
-40℃~+85℃
Permissible relative
humidity
95%RH,no condensation
EMC test
EN 55024:2011-09
EN 55022:2011-12
Vibration/shock
resistance
EN 60068-2-6/EN 60068-2-27/29
EMC resistance burst/
ESD
EN 61000-6-2 /EN 61000-6-4
Protection class
IP 20
Basic information
Dimensions
100mm *69mm *12mm
Weight
50g

GC-1502 user manual
4. Disclaimer
Thank you for purchasing GCAN's GCAN series of hardware and
software products. GCAN is a registered trademark of Shenyang Vhandy
Technology Co., Ltd. This product and manual are copyrighted by Vhandy
Technology. Without permission, it is not allowed to reproduce in any form.
Before using, please read this statement carefully. Once used, it is deemed to be
an endorsement and acceptance of the entire content of this statement. Please
strictly abide by the manual, product description and related laws, regulations,
policies and guidelines to install and use the product. In the process of using
the product, the user promises to be responsible for his actions and all
consequences arising therefrom. Vhandy Technology will not be liable for any
losses caused by improper use, installation, or modification by users.
The final interpretation right of the disclaimer belongs to Vhandy Technology

GC-1502 user manual
5. Module selection table
GCAN-PLC-400 series products consist of a programmable main control
module, several GC series IO modules and a terminal resistance module.
GC series IO modules currently include five categories: digital input, digital
output, analog input, analog output, and communication extension. The specific
selection table is shown in Table 5.1.
I/O
Type
Characteristic
Signal
Channel
PLC
Control
module
GCAN-PLC-400
CPU:168M
-
-
GCAN-PLC-510
CPU:400M
-
-
GCAN-PLC-511
CPU:400M (2CAN)
-
-
Digital
input
GC-1008
Digital input (PNP)
24V DC
8-channel
GC-1018
Digital input (NPN)
24V DC
8-channel
GC-1502
Counter(200kHz max)
-
2-channel
Digital
output
GC-2008
Digital output (PNP)
24V DC
8-channel
GC-2018
Digital output (NPN)
24V DC
8-channel
GC-2204
relay output
-
4-channel
GC-2302
PWM (20Hz~200kHz)
-
2-channel
Analog
input
GC-3604
Voltage input, 16 bits
-5~+5V
4-channel
GC-3624
Voltage input, 16 bits
10V~+10V
4-channel
GC-3644
Current input, 16 bits
0-20mA
4-channel
GC-3654
Current input, 16 bits
4-20mA
4-channel
GC-3664
Voltage input, 16 bits
0~+5V
4-channel
GC-3674
Voltage input, 16 bits
0~+10V
4-channel
GC-3804
2-wire PT100, 16 bits
Thermal
resistance
4-channel
GC-3822
3-wire PT100, 16 bits
Thermal
resistance
2-channel

GC-1502 user manual
GC-3844/3854/3
864
K type / S type / T type
thermocouple
Thermocouple
4-channel
Analog
output
GC-4602
Voltage output, 16 bits
-5V~+5V
2-channel
GC-4622
Voltage output, 16 bits
-10V~+10V
2-channel
GC-4642
Current output, 16 bits
0-20mA
2-channel
GC-4652
Current output, 16 bits
4-20mA
2-channel
GC-4662
Voltage output, 16 bits
0~5V
2-channel
GC-4672
Voltage output, 16 bits
0~10V
2-channel
GC-4674
Voltage output, 12 bits
0~10V
4-channel
Special
module
GC-6101
RS232/RS485 extension
-
-
GC-6201
GPRS extension
-
-
GC-6221
4G extension
-
-
GC-6501
WiFi extension
-
-
Table 5.1 Selection table
Table of contents
Other GCAN Control Unit manuals
Popular Control Unit manuals by other brands

Burkert
Burkert 2101 operating instructions

CDV Group
CDV Group CA-A470-A instruction manual

Danfoss
Danfoss TE 5 installation guide

KERAFLO
KERAFLO AYLESBURY K installation guide

STG-BEIKIRCH
STG-BEIKIRCH MZ2 DGM Technical information and operating instruction

Burkert
Burkert 2100 series operating instructions