INSTALLATION
INSTRUCTIONS
Product Summary
The HiTech Handheld Wireless Touchpad is a pocket-
sized, lightweight, portable touchpad that uses ITI Learn
Mode™technology to control an ITI control panel.
The touchpad gives you the flexibility to arm and
disarm the system, bypass sensors, control lights, send
emergency alarms, and check the system’s status at your
convenience.
The touchpad features include the following:
νAutomatic Low battery reports to the panel
νRed/Green indicator light that responds differently
to regular keypresses and panic button keypresses
νPolice, Fire, and Auxiliary panic buttons
νAutomatic supervisory reports to the panel every 64
minutes
νLong life (5–8 years) 3 VDC lithium battery
νOperating temperature range: 10° to 120°F
νWall-mounting option
νLearn Mode technology makes panel programming
easy
νConvenient size and attractive style
νCompatible with all ITI Learn Mode panels,
including CareTaker®Plus, Commander 2000™,
Concord, and SX-V Special.
Installation Guidelines
Observe the following guidelines when using and
mounting the touchpad:
νRefer to the appropriate Reference Manual for
guidelines on typical range for using this and other
wireless devices.
νAvoid moist areas.
νAvoid excessive metal or electrical wiring, including
furnace and utility rooms.
νAvoid exceeding the touchpad’s operating
temperature limits of 10° to 120°F (-12.2° to 49°F)
Note: If the touchpad is wall mounted or always kept at
the installation site, set upper sensor number 89
to ON. If the touchpad will occasionally be
removed from the site (i.e. kept in an automo-
bile), set upper sensor number 89 to OFF.
Installing the Battery
To install the battery:
1. Remove the battery cover by pressing down on the
arrowhead and sliding it out (see Figure 1).
Figure 1. Removing the battery cover
123
6
9
8
5
4
7
ST
0
BY
OFF STAY AWAY
NO DELAY
CHIME
STATUS BYPASS
COMMAND
8341G02A.DS4
60-597
123
6
9
8
5
4
7
ST
0
BY
OFF STAY AWAY
NO DELAY
CHIME
STATUS BYPASS
COMMAND
8341G01A.DS4

Page 2
HiTech Handheld Wireless Touchpad
2. Drop the battery into the chamber with the knob
(+) end visible (see Figure 2).
Figure 2. Placing the battery in the chamber
3. Line up the battery cover’s two exposed tabs with
the seam of the touchpad’s front and back cover
(see Figure 3).
Figure 3. Lining up the battery cover
4. Press down on the cover and slide it into place.
5. If the red light turns on steady (indicating a power-
up trouble condition), remove the battery and rein-
stall it. Repeat until the red indicator light remains
off when the cover is replaced.
Adding the Touchpad to a Panel
Before the touchpad can communicate with a panel, you
must add the touchpad to panel memory.
To add the Touchpad to panel memory:
1. Refer to the appropriate panel’s installation instruc-
tions on “entering program mode” and “adding” or
“programming a wireless touchpad.”
2. Press BYPASS when the procedure prompts for the
touchpad activation.
Mounting the Touchpad
To mount the Touchpad:
1. Test the touchpad at the desired location before
mounting and evaluate the touchpad’s performance.
2. Secure the mounting bracket to the desired surface,
using the two screws from the accessory pack (see
Figure 4).
3. Place the bottom end of the touchpad into the bot-
tom of the mounting bracket and press the touchpad
into place (see Figure 5).
Testing the Touchpad
Remind the user to test their system and this touchpad
weekly. The Owner’s Manual describes how to test the
system.
To test the Touchpad after installation:
1. To avoid an emergency response, notify the central
station that you will be testing.
2. Arm and disarm the panel from various
points to determine the touchpad’s range in
the installation site.
Note: The green light flashes with each press of a num-
ber key or function key. The red/green light
flashes with each press of a panic button.
3. Press STATUS to check the current arming
level.
4. Bypass sensors using direct and indirect
bypass.
123
6
9
8
5
4
7
ST
0
BY
OFF STAY AWAY
NO DELAY
CHIME
STATUS BYPASS
COMMAND
8341G03A.DS4
123
6
9
8
5
4
7
ST
0
BY
OFF STAY AWAY
NO DELAY
CHIME
STATUS BYPASS
COMMAND
8341G04A.DS4
EXPOSED
TAB
TOUCHPAD
SEAM
EXPOSED
TAB

HiTech Handheld Wireless Touchpad
Page 3
5. Press and hold each panic button for two sec-
onds, until the red/green indicator light stops
flashing and the appropriate alarm sounds.
6. To mute the touchpad: press the 1 and 2but-
tons at the same time, until you hear confir-
mation beeps.
Press various buttons to test the mute feature.
7. Turn off mute by pressing the 1and 2 buttons
at the same time, until you hear confirmation
beeps.
8. Turn all lights on or off by pressing COM-
MAND + 0with the Security Pro 2000 or by
pressing LIGHTS-ON or LIGHTS-OFF twice
with the Security Pro 4000.
9. Turn individual lights on or off with the
Security Pro 4000 by pressing LIGHTS-ON or
LIGHTS-OFF + [unit number]. Unit numbers
range from 1 to 9.
Note: Refer to the appropriate
Owner’s Manual
for
instructions on using the touchpad with a specific
panel.
Specifications
Battery Power Supply: 3.0 VDC lithium battery
(operating life: 5-8 years). Use either a Duracell®
DL123A, Eveready®EL123A, Panasonic®CR123A, or
Sanyo®CR123A.
Note: The 5-8 year battery life has not been verified by UL.
Operating Temperature Range: 10° to 120°F
(-12.2° to 49°C)
Dimensions: 6.1” L x 2.1” W x 0.86” H
(15.49 cm x 5.33 cm x 2.18 cm)
Compatibility: All Learn Mode panels, including:
CareTaker®Plus, Concord, Commander 2000™, and SX-
V Special.
Note: The HiTech Touchpad controls lights differently
with various panels and software versions (see
Table 1).
Table 1. Touchpad Light Control
Panel COMMAND
+ 0
Light Buttons
On Off On/Off + n
Care-
Taker
Plus 3.0
✓✓✓✓*
Care-
Taker
Plus
1.0—2.1
✓✓†
Com-
mander
2000 4.0
✓
Concord ✓✓✓ ✓
SX-V
Special ✓✓ †
*Pressing the LIGHTS-ON and LIGHTS-OFF but-
tons followed by a unit number ncontrols the lights
assigned to unit number n. Unit numbers range
from 1 to 9.
†Pressing the LIGHTS-ON button toggles all lights
on or off, the same as pressing COMMAND + 0.

Page 4
HiTech Handheld Wireless Touchpad
FCC Notice
This device complies with FCC Rules Part 15. Operation is subject to the following two
conditions:
This device may not cause harmful interference.
This device must accept any interference that may be received, including interference
that may cause undesired operation.
Changes or modifications not expressly approved by Interactive Technologies, Inc. can
void the users authority to operate the equipment.
ITI, Commander 2000, SX-V, and CareTaker are registered trademarks of Interactive
Technologies, Inc. Learn Mode is a trademark of Interactive Technologies, Inc.


This manual suits for next models
1
Table of contents
Other GE Security Touch Panel manuals