Made by: Culligan International, Westmont, IL 60559, T:(630) 654-4000
General Electric, Appliance Park, Louisville, KY 40225 ©1997 GE 49-6939-1
Performance Data Sheet
GE
Water by Culligan Filtration System
FXRC Cartridge
Health Claim Performance Certified by NSF/ANSI*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent % Reduction
MCL Challenge Average Maximum Average Minimum
Chlorine — 1.9 ppm 0.05 ppm 0.11 ppm 97 94
T & O — — — — — —
Particulate** — 303,333 10,350 15,000 96 95
Standard No. 53: Health Effects
Parameter USEPA Influent Effluent % Reduction
MCL Challenge Average Maximum Average Minimum
Turbidity 1 NTU*** 23.25 NTU 0.10 NTU 0.17 NTU 99.6 99.3
Cysts
99.95% Reduction
664,781 120 259 99.98 99.96
Lead at pH 6.5 15 ppb 226 ppb 2 ppb 6 ppb 99 98.6
Lead at pH 8.5 15 ppb 161 ppb 6 ppb 13 ppb 96 92
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C.
** Measurement in Particles/ml
*** NTU=Nephelometric Turbidity units
Operating Specifications
àCapacity: certified for 200 gallons (757 L)
àPressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
àTemperature: 33°–100° F (0.6°–38° C)
àFlow rate: 0.5 gpm (1.9 Lpm)
General Installation/Operation/Maintenance Requirements
àFlush new cartridge at full flow for 2 minutes to purge out trapped air.
àReplace cartridge when flow becomes too slow; at least every six months.
Special Notices
àInstallation instructions, parts and service availability, and standard warranty are
included with the product when shipped.
àThis drinking water system must be maintained according to manufacturer’s
instructions, including replacement of filter cartridges.
àDo not use with water that is microbiologically unsafe, or of unknown quality without
adequate disinfection before or after the system. Systems certified for cyst reduction
may be used on disinfected water that may contain filterable cysts.
àThe contaminants or other substances removed or reduced by this water treatment
system are not necessarily in your water.
àCheck for compliance with the state and local laws and regulations.
NSF
®
3
System Tested and Certified by NSF International against ANSI/NSF
Standard 42 & 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction, Class I
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead Reduction
Mechanical Filtration Unit
Cyst Reduction
Turbidity Reduction