setting mode.
4.CH buttons:
a. In normal display mode, press and hold to search RF.
5.SNOOZE buttons:
a.In alarm mode,press the button to open snooze mode.
Manually Setting the Time, Date & Units:
1.Press and hold down the "MODE" button for 3 seconds the hour
display starts to flash, use “UP” or “DOWN” buttons to set the
correct hour.
2.Press "MODE" button to confirm your setting, the minute display
starts to flash, use “UP” or “DOWN” buttons to set the correct
minute.
3.Press "MODE" button to confirm your setting, the year display
starts to flash, use “UP” or “DOWN” buttons to set the correct year.
4.Press "MODE" button to confirm your setting, the month display
starts to flash, use “UP” or “DOWN” buttons to set the correct
month.
5.Press "MODE" button to confirm your setting, the date display
starts to flash, use “UP” or “DOWN” buttons to set the correct date.
6.Press "MODE" button to confirm your setting,the DAYLIGHT
SAVING TIME display, use the “UP” or “DOWN”buttons to select
turn on or off the DAYLIGHT SAVING TIME.
7.Press "MODE" button to confirm your setting, the TIME ZONE
display,use the “UP” or “DOWN” buttons to select the TIME
ZONE.The TIME ZONE order is:EST AST HAST AKST PST MST
CST.
8.Press "MODE" button to confirm your setting, the temperature
Unit starts to flash,use “UP” or “DOWN” buttons to set the correct
temperature Unit.
9.Press "MODE" button to confirm your setting and to end the
setting procedures, enter the normal mode.
NOTE: You will automatically exit settings mode if no buttons are
pressed for 30 seconds. Enter settings mode again at any time by
pressing and holding the MODE button for 3 seconds.
Setting the Alarm:
1.In normal display mode, press ALARM button enter alarm
mode.Use “UP” button to open and close alarm.
2.Under the alarm mode,Press and hold the ALARM
button,the hour display starts to flash, use “UP” or “DOWN”
buttons (press and hold to fast adjust) to set the correct hour.
3.Press and hold the ALARM button,the minute display starts to
flash, use “UP” or “DOWN” buttons (press and hold to fast
adjust) to set the correct minute. And press the ALARM button
again to exit alarm settings.
4.To turn the alarm ON or OFF, press the ALARM button to
enter alarm mode, press the UP button to ON or OFF the
alarm. The “ ” symbol should show next to the clock display
when alarm is set to ON. Press the UP button again to turn off
the alarm, when the alarm is set to OFF, the“ ”symbol should
not display.
5.When the alarm is in operation it will begin beeping with one
short beep and continue with many short beeps if the alarm
rings longer than 20 seconds. You can snooze the alarm for 5
minutes by pressing the SNOOZE button.
Indoor / outdoor temperature
Description of control
1.Alarm icon
2.Symbol Radio Control RCC
3.Time display
4.Display low battery indicator
5.Snooze icon
6.Weekday display
7.Calendar display
8.Outdoor temperature
9.Outdoor sensor signal strength
10.Tendency outdoor temperature
11.Moon phase
12.Indoor temperature
13.In/Outdoor temperature max/min record
14.Sensor low battery indicator
15.Tendency indoor temperature
16.SNOOZE button
17. CH button
18. DOWN/MEM button
GEEVON Digital Wall Clock with Thermometer
Item No.T208614
User Manual
Thank you for purchasing T208614 Digital Wall Clock.
Please take a moment to read this guide
and store it for future reference
19. UP /RCC/ 12/24 button
20. MODE /ALARM button
21. Battery Compartment 3xAAA (batteries not included)
22. Stand bracket
23. Wireless signal indicator (Flashes when data is being sent
to the display unit)
24. Integrated hang hole
25. Compartment 2xAAA batteries (batteries not included)
Package Contents:
1. Display Unit
2. Outdoor Sensor
3. Instructions Manual
Installing or Replacing Batteries:
We recommend using high quality batteries for the best
product performance.Heavy duty or rechargeable batteries are
not recommended. The outdoor sensor requires lithium
batteries in low temperature conditions. Cold temperatures can
cause alkaline batteries to function improperly.
Do not mix old and new batteries. Do not mix alkaline,
standard, and/or rechargeable batteries.
Default settings
1. Default time: 12:00 (Time form: 12H)
2. Default date: 01/01 (Year: 2017, date form: M/D)
3. Default week: SUN
4. Default temperature: °F
5. Default alarm:AM 6:00,default snooze time: 5min.
Display / Keys Details:
There are totally 5 keys for the alarm clock,they are included:
MODE/ALARM, UP/12/24, DOWN/MEM, CH,SNOOZE.
1. MODE/ALARM buttons:
a. Press and hold for 3 seconds during normal mode to enter
setting mode.
b. Press MODE/ALARM button during normal mode to enter
alarm mode.
2.UP/RCC/12/24 buttons
a.In normal display mode, press this button to switch 12/24 hour.
b.Press and hold for 3 seconds to turn on or turn off RCC.
c.In alarm mode,press this button to open and close alarm.
d. Press to increase the setting value during setting.
e. Press and hold 3 seconds button for fast adjust during setting
mode.
3.DOWN/MEM buttons:
a.Press the button to display max/min temperature.
b.Press and hold the button 3 seconds to clear the record of
MAX/MIN temperature.
c.Press the button to display tendency in/outdoor temperature icon.
d. Press to increase the setting value during setting.
e. Press and hold 3 seconds button for fast adjust during

TROUBLESHOOTING:
Problem
No outdoor
sensor
reception
Inaccurate
temperature
/humidity
Care and
maintenance
If your Geevon product does not operate properly after trying the
troubleshooting steps, contact the seller on your order page or
If the temperature is higher than the detection range, HH will
display on screen for indication; if lower than the detection
range, LL will display on screen for indication.
Possible Solution
1.Indoor temperature -10°C – 70°C
2.Outdoor temperature-40°C – 70°C
Accuracy
1. Temperature accuracy: -40°C ~ -20°C: ± 4°C
-20°C ~ 0°C: ± 2°C
0°C ~ +50°C: ±1°C
Note: when the temperature in 50°C ~ 70°C range, the
temperature is only for reference.
MAX/MIN Temperature
1.Press a the MEM button to display the maximum temperature.
Note the MAX on the display.
2.Press the MEM button again to display the minimum
temperature. Note the MIN display.
3.Press and hold the MEM button for 5 seconds to clear the
MAX/MIN temperature readings.
Low Battery Indicator
If the low battery indicator is displayed on the LCD for either
the outdoor sensor or the display unit, immediately change the
batteries to prevent disruptions in communications of the
devices.
Moon Phase
Important Placement Guidelines
a. The sensor must be placed outside to observe outdoor
conditions. It is water resistant and designed for general outdoor
use, however, to prevent damage place the sensor in an area
which is protected from the direct weather elements and direct
sunshine. The best location is 4 to 8 feet above the ground with
permanent shade and plenty of fresh air to circulate around the
sensor.
b. Display unit and outdoor sensor must be within 200 feet of
each other.
c. In order to maximize the wireless range, place units away from
large metallic items, thick walls, metal surfaces or other objects
that may limit wireless communications.
d. To prevent wireless interferences, place both units at least 3
feet away from electronic devices (EX: TV, computer, microwave
etc.)
Outdoor Sensor Placement
a. The sensor must be placed outside to
observe outdoor conditions. It is water
resistant and designed for general
outdoor use, however, to prevent
damage place the sensor in an area
which is protected from the direct
weather elements and direct sunshine.
The best location is 4 to 8 feet above
the ground with permanent shade and
plenty of fresh air to circulate around the
sensor.
b. Display unit and outdoor sensor must
be within 100 feet of each other.
c. In order to maximize the wireless
range, place units away from large
metallic items, thick walls, metal
surfaces or other objects that may limit
wireless communications.
d. To prevent wireless interferences,
place both units at least 3 feet away
from electronic devices (EX: TV,
computer, microwave etc.)
Outdoor Sensor Function:
a. Once the display unit has been set
up and the channel synchronized with
the outdoor sensor, the display unit will
begin the registration process. It can
take up to 3 minutes to complete the
registration, where the display unit will
search for an RF (Radio Frequency)
signal from the outdoor sensor. The
outdoor sensor signal strength will show
the connection strength to the outdoor
sensor. If there are no bars or if bars are
not showing at its maximum strength (4
bars) (3) try placing the outdoor sensor
or display unit elsewhere for better
connection.
b. If the RF Signal was lost and not
reconnected, the outdoor
temperature level will begin to flash
after 1 hour of lost connection. If no
connection was found after 2 hours only
a dotted line ‘ - - - ’ will be displayed in
place of the temperature level.
c. To manually restart the RF registra-
tion, press and hold the “CH” button for
3 seconds. The display unit will now
search for the RF signal for the next 3
minutes.
Flashing of the outdoor reading is generally an indication of wireless
interference.
1. Bring both of the sensor and display indoors, side by side and
remove batteries from each.
2. Power the weather station as described in Getting started.
3. Insert the batteries in the external sensor. Automatic data will be
transmitted.
1. Temperature accuracy:
-40°C ~ -20°C: ± 4°C
-20°C ~ 0°C: ± 2°C
0°C ~ +50°C: ±1°C
2. When it is first stalled,it takes at least 1 Hour to have accurate
temperature data.
3. Make sure both the main unit and sensor are placed out of
direct sunlight and away from any heat sources, vents or
moisture sources.
4. Do not tamper with the internal components.
1. To maximize wireless range, place units away from large metallic
items, thick walls, metal surfaces, or other objects that may limit
wireless communication.
2. Please immediately change the batteries if the low battery indicator
is displayed on the LCD for sensor.
3. Do not clean any part of the product with benzene,thinner or other
solvent chemicals. When necessary, clean it with a soft cloth.
4. Never immerse the product in water. This will damage the product.
5. Do not subject the product to extreme force, shock, or fluctuations
in temperature.
1. Reload the batteries of both outdoor sensor and main unit.
(Please refer to the SENSOR SETUP section.)
2. Press and hold the CH button to receive RF signal.
3. Relocate the main unit and/or the outdoor sensor. The units
must be within 200 ft (60m) of each other.
4. Make sure both units are placed at least 3 ft (1m) away from
electronics that may interfere with the wireless communication
(such as TV, microwave, computer, radio, etc).
5. Do not use heavy duty or rechargeable batteries. The outdoor
sensor requires lithium batteries in low temperature conditions.
Cold temperatures would cause alkaline batteries work improperly.
6. Do not mix old and new batteries.
Outdoor
Reading
Is Flashing
or Showing
Dashes
"HH/LL"
display
in indoor
and/or
outdoor
temperature
EC REP
Web: www.geevon.com
E-mail:[email protected]
Prolinx GmbH
Brehmstr.56,40239 Duessldorf
Germany MADE IN CHINA