gefran eView BOX Quick guide

1
80949_MAN_eView BOX_05-2019_ENG
ATTENTION!
This manual must always be available to operators of the
devices described here.
Always make sure that you have the latest version
of the manual, which is available for free download from the
GEFRAN website (www.gefran.com).
Installers and/or maintenance personnel are required to
read this manual and to precisely follow the instructions con-
tained in it and in its attachments.
GEFRAN will not be liable for any damage to persons
and/or property, or to the product itself, caused by failure to
follow the instructions and observe the warnings given below.
This manual and its attachments may be freely reproduced
as long as they are not changed in any way and every copy
contains this warning and the declaration of ownership by
Gefran S.p.A.
INSTALLATION AND INSTRUCTION
MANUAL
code: 80949_05-2019_ENG
eView BOX
Internal cabinet control panel
This document is the property of GEFRAN and may not be reproduced or transferred to third parties without authorization.

280949_MAN_eView BOX_05-2019_ENG
DATE CODE UPDATE
05-2019 80949 First emission
REVISION DOCUMENTS

3
80949_MAN_eView BOX_05-2019_ENG
SUMMARIES AND TABLES OF CONTENTS
REVISION DOCUMENTS ...................................................2
SUMMARIES AND TABLES OF CONTENTS....................3
PREFACE............................................................................4
Warnings and safety..........................................................4
Printing conventions used in the manual ..........................4
Glossary ............................................................................4
eView BOX internal cabinet control panel ......................5
Panorama of the solution and its functions .......................5
Architecture .......................................................................6
Main power supply ..........................................................10
Programming tool............................................................ 11
GF_PROJECT VX ...................................................... 11
Technical data .................................................................12
Dimensions and spaces required for installation.............14
Order codes ....................................................................15
Accessories.....................................................................15
ASSEMBLY AND INSTALLATION ...................................16
Assembly Control Panel..................................................16
Hole dimensions .........................................................16
Protection against inltrations of water.......................16
Vibration .....................................................................16
Minimum spaces for ventilation ..................................16
Positioning ..................................................................16
Fastening....................................................................17
Control Panel Connections .............................................18
Inputs, ports and signals.............................................18
Power..........................................................................19
KEY & LED .................................................................19
USB ............................................................................20
Ethernet ......................................................................20
RS232.........................................................................20
RS485.........................................................................20
CAN ............................................................................21
Rotary selector............................................................22
SD Card......................................................................22
COMMISSIONING.............................................................23
Preliminaries Actions.......................................................23
Remote system management with GSetup.....................23
Authentication.............................................................24
Conguration ..............................................................24
Remote Connection ...................................................25
Information..................................................................26
Temperature................................................................27
Resolution...................................................................28
MAINTENANCE AND DIAGNOSTICS .............................29
WEEE Information...........................................................29
Local diagnostics.............................................................29
Control Panel..............................................................29
Diagnostics program .......................................................29
CANopen ....................................................................30
EtherCAT ....................................................................31
GDNet.........................................................................32
GILOGIK II..................................................................33
ICT..............................................................................34
System........................................................................37

480949_MAN_eView BOX_05-2019_ENG
Glossary
Bootloader Program that, in the startup (boot), loads
the PLC.
Checksum Sequence of bits that is used to verify the
integrity of a le
COBID Communication OBject IDentier, identi-
cativo a 11-bit identier of a CAN frame.
MD5 Algorithm used to calculate the checksum
of the le
PDO Process Data Object.
SDO Service Data Object.
Watchdog Supervision system hardware or software
that recovers temporary and brief system
malfunctions.
Warnings and safety
Printing conventions used in the manual
PREFACE
While all the information contained in this manual has been
carefully checked, Gefran S.p.A. accepts no responsibility for
the possible presence of errors or for damage to persons
and/or property caused by the improper use of the manual.
Gefran S.p.A. also reserves the right to make changes to the
contents and form of this manual and to the characteristics of
the devices illustrated at any time and without prior warning.
The installation of the devices illustrated in the manual must
be carried out by qualied technicians in compliance with
the laws and standards in force and in agreement with the
instructions contained in the manual.
If the eView BOX internal cabinet control panel is used in
applications with the risk of damages to persons, machinery
or materials, its use in conjunction with alarms is essential.
It is advisable to envisage the possibility of checking the
intervention of the alarms during regular operation.
Before interacting with the eView BOX internal cabinet
control panel, the operator must receive full training in
the procedures of operation, emergency, diagnosis and
maintenance of the system.
Pay attention to the use of the following symbols
Highlights particularly important information which
inuences the correct operation of the product or
of safety or an instruction which must absolutely
be followed.
Highlights a risk condition for the safety of the
installer or the user, due to the presence of
dangerous levels of voltage.

5
80949_MAN_eView BOX_05-2019_ENG
eView BOX internal cabinet control panel
Panorama of the solution and its functions
The eView BOX internal cabinet control panel lets you display,
set, and manage all of the machine or system automation
data. The use of an Intel ATOM low-consumption processor,
plus an extremely efcient design (no fans or moving parts),
eliminates all maintenance. The processor can run at either
1 GHz or 1.3 GHz.
The controller has several communication ports (USB,
Ethernet, RS232, RS485 and CAN) and different protocols
(Ethercat (Master), GDNET (Master), Modbus TCP/IP
(Master\Slave), CANopen (Master), Modbus RTU (Master/
Slave)).
The 2 GB internal mass memory can be expanded with SD
cards.
Programming is done with a single development tool: GF_
Project VX, which ensures complete and fast management
of application software by means of the ve standard
IEC61131-3 languages and a powerful graphic editor.
In combination with I/Os, eView BOX completes the
management and control of process and automation. It
manages sequences and work processes, and sets and
displays data and connectivity.
In addition, there is a series of specic application templates,
user-friendly and easily customizable, for the plastics and
heat treatment industries.
Applications:
• Plastic Extrusion
• Heat treatment
• Metal
Main characteristics:
• One programming environment.
• IP20 protection level
• wide range of communication ports and protocols
Code According to model (see order code)
Brief description Internal cabinet control panel

680949_MAN_eView BOX_05-2019_ENG
Architecture
Figure 1 - Ethernet - EtherCAT architecture
Figure 2 - Ethernet - GDnet architecture
eView BOX
Internal cabinet control panel
AXV300
ServoDrive
GILOGIK II
remote IO
GILOGIK II
remote IO
GILOGIK II
remote IO
GDnet
Ethernet
Ethernet
eView BOX
Internal cabinet control panel
eView LT104
Control Panel
GFX4
Power Controller
Third-party
remote IO
EtherCAT
Ethernet
Ethernet

7
80949_MAN_eView BOX_05-2019_ENG
Figure 3 - Ethernet - CAN (CANopen) architecture
Figure 4 - Ethernet – Modbus TCP architecture
eView BOX
Internal cabinet control panel
CANopen
Ethernet
Ethernet
GILOGIK II
remote IO
Third-party
Drive
ADV200
Drive
GFXTERMO4
Controller
MK4-C
position transducer
eView BOX
Internal cabinet control panel
Modbus TCP
Ethernet
Ethernet
Third-party
Drive
ADV200
Drive
GFXTERMO4
Controller
Third-party
remote IO
/TCP

880949_MAN_eView BOX_05-2019_ENG
/RTU
eView BOX
Internal cabinet control panel
Modbus RTU
Ethernet
RS485
GFX4
Power Controller
650
Controller
ADV200
Drive
Figure 5 - Example of Ethernet - Modbus RTU (RS485) architecture
eView BOX
Internal cabinet control panel
RS232USB
Figure 6 - Example with USB and RS232 ports
Printer
Printer USB driveBarcode
reader
Keyboard Mouse
Balance

9
80949_MAN_eView BOX_05-2019_ENG
Figura 7 - Examples of remote services
eView BOX
Internal cabinet control panel
Ethernet
SCADA ftp://
Monitoring Data Exchange Remote Pages File Exchanges Desktop Remote
Web browser Modbus TCP Java Tecnology File Transfer Protocol Virtual Network
Computing
Programming Tool
On Line Service

10 80949_MAN_eView BOX_05-2019_ENG
eView BOX
Internal cabinet control panel
Main power supply
The system is powered with ONE (1) power supply as shown in gure 8.
To power the system correctly, make sure that:
• The power supply has the power needed to run the system
and any additional resources connected to it.
• Ground the power supply (GND) with a wire that is straight and
as short as possible (PE).
• Ground the eView BOX ground terminal and the with a
wire that is straight and as short as possible (PE).
• Insert the ferrites into the power supply cables as close as
possible to the eView BOX Control Panel.
• The system power supply line must have a different path
from the plant and machine power cables.
Figure 8: Single power supply
+24Vdc
0V
PE
PS AUXILIARY
DE VICES
AC Line
Ferrite
Bead

11
80949_MAN_eView BOX_05-2019_ENG
Programming tool
GF_PROJECT VX
Development software that allows the writing of the application program for PLC with IEC1131 languages. Also allows the
construction, in graphic mode, of the various pages of the user interface necessary to the application developed.
Via GF_PROJECT LX it is possible to connect to the device that will host the application to debug the program and upload
the upgrades.
See the GF_Project VX manual for operating instructions.
System requirements
Minimum Recommended
Operative system Windows XP SP2 or Windows Vista Windows 7 (64 bit) / Windows 10 (64 bit)
Processor Intel Pentium 1 GHz Intel Core i5 2,5 Ghz or superior
RAM 2 GB 4 GB or greater
Free space on Hard Disk 2 GB 4 GB or greater
Graphic resolution XGA (1024 x 768 pixel) SXGA (1280 x 1024 pixel) or superior
Browser Microsoft Internet Explorer 8.0 Microsoft Internet Explorer 9.0
Ethernet Port 1 RJ45 1 RJ45
DVD player Yes Yes
USB port 1 USB 2.0 1 USB 2.0

12 80949_MAN_eView BOX_05-2019_ENG
eView BOX
POWER SUPPLY
Operating voltage 24 VDC ±25%
Current draw
(at 24 VDC) 500 mA max
Power dissipation 12 W max
Protections Polarity inversion
Short circuit
Connection 3-pin polarized removable connector
Screw terminals, max cable section 2.5 mm2
CONNECTIONS
Ethernet port (ETH) Number of channels: 2 max (1 optional)
Connector: RJ45
Velocity: 10 / 100 / 1000 Mbit/s
Signals: green connection LED, yellow data LED
KEY & LED port Connector: RJ45
Standard: USB2.0
RS-232 port (optional) Connector: DB9 M
Speed: 1.2kbit/s…115kbit/s
RS-485 port (optional) Optically isolated
Connector: DB9 M
Speed: 9 kbit/s … 19 kbit/s
Terminations and polarization: internal, selectable with jumper
CAN port (optional) Optically isolated
Connector: DB9 M
Speed: 20, 50, 100, 125, 250, 500, 1000 kbit/s, default 500
kbit/s
Termination: internal, selectable with jumper
USB port Number of ports: 2 max
Connector: type A
Standard: USB 2.0
Protection: overload
COMMUNICATION
PROTOCOLS
Ethernet FTP (File Transfer Protocol) Modbus TCP/IP Master/Slave
Ethercat Master
GDNET Master
CAN CANopen Master
Modbus Modbus RTU Master/Slave
CONFIGURATION
ELEMENTS
Access to software
procedures 16-position rotary switch
Touch screen calibration Via software on product
CONTROL ELEMENTS Touch screen 4-wire resistive technology
VIEWING ELEMENTS
Diagnostics PW LED (yellow): power supply on
RN LED (green): PLC program state
LED E1 (red): HW Watchdog state
LED E2 (red): PLC program error
MICROPROCESSOR Type and frequency ATOM E640 1 GHz
ATOM E660, 1.3 GHz
MEMORY
System 512 MB, DRAM type DDR II
Mass 2 GB Flash memory
Mass extension SD Card Slot *
Technical data

13
80949_MAN_eView BOX_05-2019_ENG
eView BOX
AMBIENT CONDITIONS
Operating temperature 0 ... +55 °C (as per IEC 68-2-14)
Storage temperature -20 ... +70 °C (as per IEC 68-2-14)
Relative humidity max 95% RH non condensing (as per IEC 68-2-3)
Vibrations 5 to 9 Hz: sine constant 3.5 mm
10 to 150 Hz: sine acceleration 1G
ASSEMBLY Mounting inside the control panel, horizontally with the DIN bar
or vertically with xing screws.
PROTECTION LEVEL IP 20 (as per IEC 68-2-3)
WEIGHT 1,250 kg
CE STANDARDS
EMC
(electromagnetic
compatibility)
Conforms to Directive 2014/30/EU
EN61131-2: Programmable controllers
Part 2: Equipment requirements and tests.
* SD card not supplied. Available as accessory

14 80949_MAN_eView BOX_05-2019_ENG
Dimensions and spaces required for installation
Dimensions in mm
217
232
203
44.6
33
16.3118
3
6 134.3
5.5
Figure 9 - eViewBOX dimensions
Dimensions in mm
Figure 10 - Space for ventilation
Attention: the temperature in the compartment containing the internal cabinet control panel must never exceed
55°C.
The open spaces shown in gray are recommended with static ventilation. These spaces may be reduced with forced ventilation.

15
80949_MAN_eView BOX_05-2019_ENG
Order codes
eView BOX with Atom 1 GHz, 512 MB RAM, 2 GB ash memory
Code Model Number Description
F073912 eView BOX-20-E1-00-00 communication peripherals
2 x Ethernet (Modbus TCP, GDNet), 2 x USB, 1 x keyboard eKMxx
F073914 eView BOX-20-E1-S1-C1
communication peripherals
2 x Ethernet (Modbus TCP, GDNet), 2 x USB, 1 x keyboard eKMxx, 1 x RS232,
1 x RS485, 1 x CAN (CANopen)
eView BOX with Atom 1.3 GHz, 512 MB RAM, 2 GB ash memory,
Code Model Number Description
F073915 eView BOX-30-E1-00-00 communication peripherals
2 x Ethernet (Modbus TCP, GDNet), 2 x USB, 1 x keyboard eKMxx
F073916 eView BOX-30-E1-S1-C1
communication peripherals
2 x Ethernet (Modbus TCP, GDNet), 2 x USB, 1 x keyboard eKMxx, 1 x RS232,
1 x RS485, 1 x CAN (CANopen)
F079039 eView BOX-30-E2-S1-C1
communication peripherals
2 x Ethernet (Modbus TCP, GDNet\EtherCAT), 2 x USB, 1 x keyboard eKMxx,
1 x RS232, 1 x RS485, 1 x CAN (CANopen)
Accessories
Code Model Number Description
F067831 CAV_USB_PANEL_1m USB cable to panel L = 1 m
F057777 SD_CARD1G SD Card 1GB
F057679 USB_PEN1G 1 GB USB key

16 80949_MAN_eView BOX_05-2019_ENG
ASSEMBLY AND INSTALLATION
Assembly Control Panel
Hole dimensions
For correct installation, observe the dimensions of the
templates shown in the illustration.
Protection against inltrations of
water
The internal cabinet control panel offers an IP20 protection
level.
If the product has to be used in an environment in which a
protection level higher than IP20 is required, this must be
guaranteed by the cabinet that hosts the product itself.
Vibration
The internal cabinet control panel can support vibrations:
• from 5 to 9 Hz: sinusoidal 3.5 mm constant;
• from 9 to 150 Hz: sinusoidal with acceleration equal to
1 G
Should the device be mounted on a support that exceeds
these limits it is necessary to envisage a system for the
suspension and mitigation of the vibrations.
Minimum spaces for ventilation
The temperature of the compartment that houses the internal
cabinet control panel must not exceed 55°C.
Figure 2 free spaces for ventilation show the minimum free
distances recommended in the installation of the device in a
closed compartment
Positioning
The internal cabinet control panel has to be positioned in
order to guarantee the following conditions:
• If necessary, screen direct rays, using an antiglare
shutter for example;
• there must be no sudden temperature changes;
• there must be a low explosion risk: it can be connected to
elements that operate in environments with a hazardous
atmosphere (ammable or explosive) only through
appropriate and suitable types of interface, compliant to
the safety standards in force;
• low presence of magnetic elds.
Figure 11 - Hole dimensions for installation of the internal cabinet control panel
18
26.6
217
15
5.5
Dimensions in mm
Attention: the panel on which the internal
cabinet control panel is mounted has to have
the following characteristics:
• be sufciently stiff and strong so that it does
not bend during use;
• be between 1 and 6 mm thick, to allow the
fastening of the device with the terminals
supplied.

17
80949_MAN_eView BOX_05-2019_ENG
Figure 12 - Installation on DIN track
Fastening
The internal cabinet control panel can be installed in two
ways:
• horizontal on DIN 35 mm track, Fig.12.
• vertical, Fig.13.
• Horizontal mounting:
Install the 2 brackets for the DIN 35 track as shown in Fig.12.
Fasten the product and press hard to complete the operation,
rotating downwards.
• Vertical mounting:
Prepare the M5 threaded holes, done with the template as
shown in Fig.11, position the product and screw in place as
shown in Fig.13.
Warning: install locking washers to prevent the screws from
loosening!
Figure 13 - Vertical installation

18 80949_MAN_eView BOX_05-2019_ENG
Inputs, ports and signals
Figure 15 - Position of user connectors
Control Panel Connections
No Description Connector / indicator Notes
124 VDC ± 25% power supply input Removable polarized terminal block
2LED PW (yellow): power ON
RN (green): PLC program status
E1 (red): local I/O bus error
E2 (red): HW Watchdog status
3Supplemental Ethernet port RJ45 optional
4Ethernet port RJ45
5KEY & LED RJ45 For GEFRAN Keypad
6RS232 DB9 M (D-sub 9-pin male) optional
7RS485 DB9 M (D-sub 9-pin male) optional
8CAN DB9 M (D-sub 9-pin male) optional
9Porta USB Type A
10 Porta USB Type A
11 J2 Jumper Conguration of RS485 polarization
and termination
12 J1 Jumper Conguration of CAN termination
13 Rotary 16-position Rotary
14 SD Card Slot Standard SD Card SD card not supplied. Available as
accessory
12345678
9101112
1314

19
80949_MAN_eView BOX_05-2019_ENG
Power
The eView BOX internal cabinet control panel must be
connected to a 24 Vdc power supply unit.
The same 24 VDC power supply can feed other devices as
well. Make sure that the current issued by the power supply
is higher than the total maximum current absorbed by all the
devices connected.
230 VAC
24 VDC
-
+
Figure 16 - eViewLT power
Considering that the device has no switch, it is necessary to
install one before it, with a protective fuse.
The switch has to be positioned in the immediate vicinity of
the device and be easy for the operator to reach.
For the 24 Vdc power supply, use a separate line from that
used for electromechanical power devices such as relays,
contactors, solenoids, etc.
If there are considerable changes in the mains voltage, use a
voltage stabiliser.
Near to high frequency generators or arc welders, use
adequate grid lters.
Connect the power cables to the power connector.
Assemble the ferrite (supplied) as close as possible to the
device to limit its susceptibility to electromagnetic noise
(gure 17).
The 24 Vdc power cables must follow a separate route from
the power cables of the system or the machine.
Figure 17 - eView BOX power connection
Attention: make sure that the earth connection
is efcient. A non-existent or inefcient earth
connection can make the operation of the
device unstable, due to excessive environmental
disturbance.
In particular, check that:
• the voltage between ground and earth is < 1 V;
• the ohm resistance is < 6 Ω.
• the wire is as short as possible and without
curls
KEY & LED
With this RJ45 connector, the port provides a connection for
Gefran keyboards. Up to 128 keys and up to 64 LEDs can be
managed. Communication uses the USB 2.0 standard.
Connection with keyboards is straight point to point.
Maximum cable length: 5 meters.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Straight cable
Figure 18 - RJ45 wiring of keys & LEDs for Gefran
keyboards

20 80949_MAN_eView BOX_05-2019_ENG
USB
The USB ports let you connect external devices conforming
to the USB standard.
The connectors are Type A and the ports support the USB
2.0 standards, with speed up to 480 Mbit/s.
The ports can deliver 500 mA current at 5 VDC to power
external USB devices. The USB cable can have a maximum
length of 5 meters.
Use approved USB 2.0 cables.
Logging from panel into the controller’s USB port is possible
through the carry-over cable (separately sortable). In order
to set the grip of this cable, the thickness of the panel in the
chosen position mustn’t be higher than 2 mm.
Ethernet
The Ethernet port lets you connect the controller to a
computer or a corporate LAN or, if the product has the option,
to an ETHERCAT network.
Pin Name Description
1 TX+ Data transmission +
2 TX- Data transmission -
3 RX+ Data receiving +
4
5
6 RX- Data receiving -
7
8
The connection cable to use, straight or crossover, depends
on the type of device that should be connected.
For example, to connect directly to a PC with a crossover
cable must be used.
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
Straight cable Crossover cable
Figure 19 - Straight and crossover Ethernet cables
For the connection, use a CAT6 UTP cable or superior, You
can also use a CAT5e cable (only for ETHERCAT).
The maximum length of the Ethernet cable is 100 metres.
Do not run the Ethernet cable alongside the machine power
cables, to avoid interference with data transmission.
The RJ45 socket has two LEDs. When the Ethernet connection
is active, the green LED stays permanently lit; when data is
being transmitted, the yellow LED ashes
RS232
The RS232 port is optional. Considering that the RS232 port
is not insulated, it is necessary to disconnect the power to
the Integrated Controller and internal cabinet control panel
and to the device to be connected before connecting them.
The connection cable must be screened and not exceed a
length of 3metres. Tighten the cable connector to that of the
controller using the special screws.
1
9
Pin Name Description Signal
1
2 RxD Received Data Input
3 TxD Transmitted Data Output
4
5 GND Ground Ground
6
7RTS Request To Send Output
8 CTS Clear To Send Input
9
RS485
The RS485 port is optional. Considering that the RS485 is
opto-isolated, it is not necessary to disconnect the power
to the internal cabinet control panel and to the device to
be connected before connecting them. Tighten the cable
connector to that of the controller using the special screws
1
9
Pin Name Description
1
2 TX/RX+ Data +
3
4 TX/RX- Data -
5 GND Ground
6
7
8
9
Do not connect any lters other than the ones
described.
The RS485 connection can be used successfully over
long distances and in environments characterised by
considerable disturbance.
The maximum length of the cable depends on the
transmission speed, as shown in gure 22.
Other manuals for eView BOX
1
Table of contents
Other gefran Control Panel manuals
Popular Control Panel manuals by other brands

Honeywell
Honeywell RS-232 installation instructions

AKO
AKO PROCool AKO-17635-1 user manual

Ness
Ness D24 Installation & programming manual

Ampac
Ampac ZoneSense Plus Installation, commissioning & operation

Schaudt
Schaudt LT 45 Series operating instructions

Flair Electronics
Flair Electronics ENS24-F instruction manual