gefran R-ECAT User manual

80118_MHW_R-ECAT_08-2021_ENG 1
R-ECAT
GATEWAY ETHERCAT CoE MODULE
INSTALLATION AND OPERATION MANUAL
cod. 80118 / Edit 01 - 08/2021 - ENG
1 • MAIN FEATURES
• Complete control of R-BUS(x) back plane
• ETHERCAT interface, CAN over ETHERCAT protocol
• Power supply of backplane
2 • INSTALLATION AND CONNECTION
This section contains the instructions necessary for correct
installation of the GILOGIK II into the machine control panel
or the host system and for correct connection of the system
power supply, inputs, outputs and interfaces.
Before proceeding with installation read the following
warnings carefully!
Remember that lack of observation of these warnings
could lead to problems of electrical safety and electromag-
netic compatibility, as well as invalidating the warranty.
Qualified staff
The installation and use of the system and components are only re-
served at qualified staff.
Conform use
the system and relative components are usable exclusively to the use
previewed in the manual In order to guarantee a correct and sure
operation are indispensable that the product comes transported, stored
correctly, installed, and controlled second the previewed modalities.
Suitable for use in pollution degree 2 environment.
Open type equipment.
Electrical power supply
• the GILOGIK II is NOT equipped with an On/Off switch: the user
must provide a two-phase disconnecting switch that conforms to the
required safety standards (CE marking), to cut off the power supply
upstream of the system. The switch must be located in the vicinity of
the system and must be within easy reach of the operator.
One switch may control more than one systems.
• To make sure that the system very is connected to earth as indicated
in the “Module power supply” section.
• if the system is used in applications with risk of damage to persons,
machinery or materials, it is essential to connect it up to auxiliary
security equipment. It is advisable to make sure that alarm signals are
also triggered during normal operation.
The dispositif must NOT be installed in flammable or explosive
environments; it may be connected to equipment operating in such
atmospheres only by means of appropriate and adequate types of
interface, conforming to the applicable safety standards.
Notes Concerning Electrical Safety and Electromagnetic
Compatibility:
CE MARKING: EMC Conformity (electromagnetic compatibility)
• Compliance with Directive 2014/30/EU
EN61131-2: Programmable controllers
Part 2: Equipment requirements and tests.
The GILOGIK II system is mainly designed to operate in industrial
environments, installed on the switchboards or control panels of pro-
ductive process machines or plants.
The Declaration of conformity is available on GEFRAN web:www.
gefran. com
• UL listed standard: UL508 file E198546.
Module power supply
• Supply with class 2 device
• The power supply to the modules on the switchboards must always
come directly from an isolation device with a fuse.
• The electronic instruments and electromechanical power devices such
as relays, contactors, solenoid valves, etc., must always be powered
by separate lines.
• When the power supply is strongly disturbed by the commutation of
transistor or power units or motors, an isolation transformer should be
used, earthing the screen.
• It is essential that the plant has a good earth connection:
- the voltage between neutral and earth must not be > 1V
-theOhmicresistancemustbe<6Ω;
• In the proximity of high frequency generators or arc welders, use
adequate filters.
• The power supply lines must be separate from the instrument input
and output ones.
GEFRAN S.p.A. declines all responsibility for any
damage to persons or property caused by tampering,
neglect, improper use or any use which does not
conform to the characteristics of the controller and
to the indications given in these Instructions for Use.

2 80118_MHW_R-ECAT_08-2021_ENG
GEFRAN spa via Sebina, 74 - 25050 Provaglio d’Iseo (BS)
Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.com
3 • TECHNICAL DATA
Power supply
- Supply with class 2 device
- 24 VDC ±25% 2A max., powers the entire GILOGIK II system
- Polarity inversion protection and short-circuit protection.
Ethernet
- Standard RJ45 - IN connection
- Standard RJ45 - OUT connection
- Number two rotary switches x01 and x10 for “Explicit Device Value”
setting of the slave
Diagnostics
- Yellow POWER led: power supply on
- Green RUN led:
INIT: steady off
PREOP: flashing slowly
SAFEOP: single flash with pause
OP: steady on
- Red ERROR led:
OFF: no errors
CONTINUOUS FLASHING: configuration error
SINGLE FLASH: generic runtime error
DOUBLE FLASH: watchdog on cyclic data
- Yellow LINK led: network connected
- Green ACTIVITY led: data transfer
Mechanical data
Dimensions: 92x90x25,4mm
Weigth: 150g.
Fixing: snaps onto R-BUS(x)
Protection level: IP20
Ambient Conditions
Working Temperature: 0...50°C
Storage Temperature: -20...70°C
Humidity: max. 90% Rh not condensing
For UL: Maximum surrounding air temperature 50°C
4 • CONNECTIONS 5 • WEEE INFORMATION
Pursuant to Article 26 of Italian Legislative Decree no. 49 of
14 March 2014 “Implementation of Directive 2012/19/EU on
waste electrical and electronic equipment (WEEE)”.
The symbol showing a crossed-out wheeled bin on equipment or its
packaging indicates that the product must be collected separately
from other waste at the end of its useful life.
The manufacturer is responsible for organising and managing the
separate collection of this piece of equipment at the end of its useful
life.
Users wishing to dispose of the equipment must therefore contact the
manufacturer to obtain instructions from the same on how to have the
equipment collected separately at the end of its useful life.
By collecting the disused equipment separately, it can be recycled,
treated or disposed of in an environmentally friendly manner, thus
helping to prevent the environment and public health from being af-
fected negatively and enabling reuse and/or recycling of the materials
forming the same equipment.
(*) Use shielded category 5E cable. In any case, for higher categories, always
use shielded cable.
Normally use straight cable for IN / OUT connection.
(**) Use unipolar cable with 1-1.5mm cross section.
The module installs on
R-BUS(x) in the first slot on
the left.
1
8
8
1
yellow POWER led
green RUN led
red ERROR led
green
ETHERCAT IN led
yellow LINK
ETHERCAT IN led
green ACTIVITY
ETHERCAT OUT led
yellow LINK
ETHERCAT OUT led
Product release
RJ45 ETHERCAT IN (*)
RJ45 ETHERCAT OUT (*)
Power supply (**)
24V DC ± 25% max 2A
Explicit Device Identification
Tens:
0..9 = 0..90
A = 100
B = 110
C = 120
D = 130
E = 140
F = 150
Explicit Device Identification
Units:
0..9 = 0..90
A , B, C, D, E, F = do not use:
reserved functions
This manual suits for next models
1