Shuttle-Type Flow Switches
FS-500 Series
Instruction Bulletin No. 170660
Typical Wiring Diagram . . .
Red
Red
SPST, N.O. at No Flow
Materials
Housing, Bonnet, Shuttle, Shuttle Cap
O-Ring
Spring
Retaining Clip
Operating Pressure, Maximum
Operating Temperature, Maximum
Set Point Accuracy
Set Point Differential
Switch (See “Switch Ratings”)
J-Box with 5A Relay
Inlet/Outlet Ports
Electric Termination
Pilot
J-Box
Polypropylene, Hydrolytically Stable
Glass-Reinforced!!
!!
!
Viton® or Buna N
316 Stainless Steel
PH 15-7 Mo Stainless Steel
100 PSIG @ +70°F
50 PSIG @ +180°F
212°F (100°C)
± 20%
± 20%, Maximum
SPST, N.O. Pilot Duty: 20 VA,
120-240 VAC or VDC
120 VAC 50/60 Hz
Contacts: 5A-240 VAC Res.
1/3 HP - 120 VAC
5A - 28 VDC Res.
3/4” Female NPT
No. 22 AWG, 24” Zip Cord Lead Wires
6’ Cable
Specifications . . .
Bonnet
Housing
3.80”
(96.5 mm) 1.8”
(45 mm)
1.48”
(37.5 mm)
2.00”
(50.8 mm) 1.32”
(33.5 mm)
Ref. Dimensions . . .
!
!
!
!
!
!
Top View
!
!
!
!
Switch Ratings
Max. Resistive Load
VA
20
Volts
0 - 30
120
240
Amps AC
.4
.17
.08
Amps DC
.3
.13
.06
Standard Models . . .
170231
170232
170233
170234
170235
0.25 GPM ± 20%
0.50 GPM ± 20%
1.00 GPM ± 20%
2.50 GPM ± 20%
5.00 GPM ± 20%
Part
Number
Switch Actuation
Set Point on
Increasing Flow
Pilot Duty
0.25 GPM ± 20%
0.50 GPM ± 20%
175901
175902
J-Box w/5A Relay
Note: Standard units are designed with springs for positive return of the shuttle at no-flow condition. This allows the flow switch to
be mounted in any orientation, but actuation set points will vary from the stated values. Contact the Factory for further information.
This product is suitable for Class I and Class II applications only, per the requirements of standard EN60730 and
any additional specific requirements for a particular application or medium being sensed. Class I compliance of
metal bodied units requires a ground connection between the metal body and the earthing system of the
installation. Class I compliance of plastic bodied units in contact with a conductive medium requires that the
medium be effectively earthed so as to provide an earthed barrier between the unit and accessible areas. For
Class III compliance, a supply at safety extra-low voltage (SELV) must be provided. Please consult the Factory
for compliance information on specific part numbers.
P/N 170660
Rev. D
Important Points!
Product must be maintained and installed in strict accordance with
the National Electrical Code and GEMS product catalog and instruc-
tion bulletin. Failure to observe this warning could result in serious
injuries or damages.
An appropriate explosion-proof enclosure or intrinsically safe inter-
face device must be used for hazardous area applications involving
such things as
(but not limited to)
ignitable mixtures, combustible
dust and flammable materials.
Pressure and temperature limitations shown on individual catalog
pages and drawings for the specified flow switches must not be ex-
ceeded. These pressures and temperatures take into consideration
possible system surge pressures/temperatures and their frequencies.
Selection of materials for compatibility with the media is critical to
the life and operation of GEMS flow switches. Take care in the proper
selection of materials of construction; particularly wetted materials.
Life expectancy of switch contacts varies with applications. Con-
tact GEMS if life cycle testing is required.
Ambient temperature changes do affect switch set points, since the
specific gravity of a liquid can vary with temperature.
Flow switches have been designed to resist shock and vibration;
however, shock and vibration should be minimized.
Liquid media containing particulate and/or debris should be filtered
to ensure proper operation of GEMS products.
Electrical entries and mounting points may require liquid/vapor seal-
ing if located in an enclosed tank.
Flow switches must not be field repaired.
Physical damaged sustained by the product may render it unser-
viceable.
Installation ...
FS-500 flow switches are for use with metal or plastic piping systems and connect to piping via the 3/4" NPT mating
thread forms. The following guidelines are provided to assist with installation for a leak-free seal, without damage to
the unit.
1. Apply pipe thread sealant to the male pipe threads.
2. Thread the flow switch onto the male pipe thread until hand-tight.
3. Tighten pipe I to 1-1/2 additional turns.
4. If improper seal results, continue turning pipe into unit in 1/4 turn increments.
Do Not Exceed One Additional Turn
Recommended Pipe Sealants: a) Permatex®“No More Leaks”b) Teflon®Thread Tape
Maintenance ...
Disassembling for Cleaning: It is not necessary to remove the unit from the piping system. CAUTION: Make sure
the system is turned off and that no residual pressure remains in the piping.
1. The bonnet assembly (see diagram below) is removed by firmly grasping the housing and turning the bonnet 45°
counter-clockwise, as indicated on the top of the bonnet. This will unlock the mating tabs on the two parts.
2. The bonnet can now be pulled out of the housing. Be sure to pull on the bonnet, as damage can be done if the
lead wires are pulled.
Cleaning: Clean shuttle, stem, spring, retaining clip and inside of housing by lightly scraping and/or wiping. Check
0-ring, bonnet assembly, shuttle, and spring for damage. Consult Factory for replacement parts, if necessary.
To Reassemble Unit ...
1 . Be sure spring is properly set within clips on shuttle cap.
2. Reposition O-ring in counter-bored shoulder of housing.
3. Insert bonnet assembly into housing, allowing tabs on bonnet to clear
mating lugs on housing. Be sure bonnet stem end aligns with centering
feature in housing.
4. Bonnet assembly can be locked by firmly grasping housing and turning
bonnet 45* clockwise, as indicated on top of bonnet. This will engage
mating tabs on the two parts.
(See exploded view at right)

Other Gems Sensors Switch manuals

Gems Sensors ELS-950 Series Training manual

Gems Sensors

Gems Sensors ELS-950 Series Training manual

Gems Sensors FS-380 Series Training manual

Gems Sensors

Gems Sensors FS-380 Series Training manual

Gems Sensors S-925 Series Training manual

Gems Sensors

Gems Sensors S-925 Series Training manual

Popular Switch manuals by other brands

Keithley 7002 Quick reference guide

Keithley

Keithley 7002 Quick reference guide

JR ProPo XBus Series Operation manual

JR ProPo

JR ProPo XBus Series Operation manual

Pilz PSEN cs4.1a/p/M12 operating instructions

Pilz

Pilz PSEN cs4.1a/p/M12 operating instructions

MobileView 3200 quick reference

MobileView

MobileView 3200 quick reference

HP HP 5120 series Configuration guide

HP

HP HP 5120 series Configuration guide

Bender ATICS DIO Series quick start

Bender

Bender ATICS DIO Series quick start

LTS POE-SW401 user manual

LTS

LTS POE-SW401 user manual

SMC Networks ZSE80 user manual

SMC Networks

SMC Networks ZSE80 user manual

Planet MGSW SERIES Quick installation guide

Planet

Planet MGSW SERIES Quick installation guide

Racepak 500-SW-PNL8 manual

Racepak

Racepak 500-SW-PNL8 manual

E-T-A 921 Series Instructions for installation

E-T-A

E-T-A 921 Series Instructions for installation

Black Box KV120A manual

Black Box

Black Box KV120A manual

Black Box LGB1001A quick start guide

Black Box

Black Box LGB1001A quick start guide

INIM Electronics enea EM600 quick start guide

INIM Electronics

INIM Electronics enea EM600 quick start guide

Planet XGSW-28040HP user manual

Planet

Planet XGSW-28040HP user manual

Black Box ServSwitch DTX5000 user guide

Black Box

Black Box ServSwitch DTX5000 user guide

3Com OfficeConnect 8 installation guide

3Com

3Com OfficeConnect 8 installation guide

GOPOD HD258B user manual

GOPOD

GOPOD HD258B user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.