Congratulations!
! On buying the device, be sure to check the delivery set, presence
and correctness of the Quality Warranty Card filling, the acceptance
certificate and product selling marks.
! Please, thoroughly read the user’s guide before using the device.
Keep the User’s guide for future use.
! Please, address to the manufacturer if you have some questions
when using the device.
Tel.: +7(495)663-22-11 (extension 109),
E-mail: geosoftdent@geosoft.ru
JSC GEOSOFT DENT
(Russia)

3
ESTUS LIGHT
www.geosoft.ru/en
CONTENTS
1. General information.......................................………………….
2. Delivery set...................................……………………………..
3. Accessories……………………………………………………..
4. “Estus Light” appearance.......................………………………
5. Technical specifications ........................……………………….
6. Preparatory stage and working procedure……………………..
7. Cleaning and disinfection …………………………………….
8. Maintenance……………………………………………………
9. Troubleshooting………………………………………………..
10. Storage, transportation and use ………………………………
11. Information on utilization…………………………………….
12. Symbol descriptions ………………………………………….
Appendix………………………………………………………….
4
10
11
14
16
20
29
30
32
34
34
35
37

4
USER’S MANUAL
www.geosoft.ru/en
1. GENERAL INFORMATION
1.1. Intended use: Dental photoactivator “Estus Light” is intended for
photopolymerization of composite light-cured filling materials
containing:
-the traditional photoinitiator camphorquinone, polymerizing in the
blue light spectrum in the range of 440-475 nm, and
- next-generation photoinitiators polymerizing additionally in the
ultraviolet light spectrum in the range 400-420 nm (for example,
“IVOCERIN” by “Ivoclar Vivadent”) during restoration work in the
patient’s oral cavity - the main purpose of the product.
The function is implemented using the polymerizing tips specified in
the table below:
The “ESTUS-BLUE POINT” tip allows to conduct the point
polymerization of photosensitive materials, for example, when
installing veneers. Also the tip is used for adhesive polymerization
inside the root canal at the stage of fixing fiberglass pins and for fixing
all-ceramic orthopedic structures, which allows to release paroxysmal
and cervical areas from the fixing material.
Additional “Estus Light” options when using special tips:
1. Transillumination - diagnostics of initial carious changes, hidden
№
Tip name Emission
spectrum, nm
Photoinitiator
1 ESTUS LED - BLUE 440-475 camphorquinone
2 ESTUS - BLUE POINT 440-475 camphorquinone
3 ESTUS - FULL BLUE 400-420, 440-475 Ivocerin, camphorquinone

5
ESTUS LIGHT
www.geosoft.ru/en
carious cavities or defects, enamel cracks, quality control of
restoration and adaptation of composite materials to hard tooth tissues
using a light source emitting in the spectrum of orange light in the
range 585-595 nm. The function is implemented with the diagnostic
tip “ESTUS LED - ORANGE”.
2. Photodynamic therapy (PDT) - diagnosing the development of
malignant tumors in the early stages, conducting cancer cell therapy,
treating discoloritis when changing color of the elements of the
dentition, performing antibacterial and antifungal treatment of the
patient’s oral cavity using special photosensitive substances
(photosensitizers), activated by the source light emitting in the red
light spectrum in the range 620-645 nm (peak 630 nm) (for example,
tolonium chloride) or in the deep red light spectrum in the range 650-
670 nm (peak 660 nm) (for example “Photoditazine”).The function is
implemented with the therapeutic tips “ESTUS LED - RED 630” or
“ESTUS LED - RED 660” accordingly.
3. Luminescent diagnostics - diagnosing of some diseases of the oral
mucosa and tongue, contrasting of the old filling material, as well as
detection of bacterial deposits on the surface of the teeth using a light
source emitting in the ultraviolet spectrum in the range of 400-420 nm
(peak 405 nm). The function is implemented with the diagnostic tip
“ESTUS LED - LUMI”.
1.2. Indication for use: The device is intended for use in dentistry
during diagnostics, therapy and restoration work in the patient’s oral
cavity. The manufacturer is not responsible for any dangerous
situation while using the device for purposes other than that
intended.
1.3. Application field: The device is for use only in medical facilities.

6
USER’S MANUAL
www.geosoft.ru/en
1.4. Potential users: ONLY the licensed dentists.
1.5. Contraindications and adverse reactions: Without finding.
1.6. Contact type with a patient: Short invasive contact through the
oral cavity.
1.7. Operating principal:
1. Polymerization: The photoactivator of the polymerization process is
a powerful light source acting on the initiator of the polymerization
process as part of a composite material. The polymerization process
(curing) of the filling material occurs by local exposure with the
emitter.
2. Photodynamic therapy (PDT): The photosensitizer is input into the
oral cavity by the most suitable way, where it selectively accumulates
in pathogenic cells without affecting healthy tissue. The affected
tissue is then irradiated with a certain wavelength emitter. As a result
of the photochemical reaction, atomic oxygen is released that destroys
pathologically changed cells and inflammatory microflora.
3. Transillumination: The effect of transillumination is based on
differences in the ability to absorb light from different tissues and
materials. It is carried out with passing rays of light, by translucence
of the tooth crown from the palatine or lingual surface. The method is
based on the assessment of shadow formations that appear when a
cold light stream of orange color passes through a tooth and is
harmless to the body.
4. Luminescent diagnostics is based on the ability of tissues and their
cellular elements to change their natural color under the influence of
ultraviolet rays.
1.8. Functional abilities:
Operation with 7 tips:
- 3 tips of the BLUE (“ESTUS LED - BLUE”, “ESTUS - BLUE

7
ESTUS LIGHT
www.geosoft.ru/en
POINT” , “ESTUS - FULL BLUE”) type;
- 2 tips of the RED (“ESTUS LED - RED 630”, “ESTUS LED -
RED 660”) type;
- 1 tip of the ORANGE (“ESTUS LED - ORANGE”) type and
- 1 tip of the LUMI (“ESTUS LED - LUMI”) type.
Automatic recognition of the connected tip type with the following
activation of the corresponding working program.
3 modes (Нigh, Мiddle, Low) for every of 7 tips with fixed values
of all working parameters:
- emitter light intensity and exposure time for the tips of BLUE and
RED type and
- emittance brightness level for tips of ORANGE and LUMI type
The chosen working mode indication on the handpiece LED scale;
Gradual light intensity increase (Soft function) when working in
polymerization mode with the tips of BLUE type.
Audio indication during operation and function of the audio signal
volume adjustment.
Indication of the power supply discharge.
Power saving function
Possibility of expanding the device functionality in terms of
settings and displaying the values of its working parameters when
the device is operating as a part of the “Estus” dental complex
together with the “Estus Multi (Plus)”* main control unit.
* not included into the delivery set and should be purchased separately,
additionally paid

8
USER’S MANUAL
www.geosoft.ru/en
1 . 9 . Precautions and Warnings
!!Use the product with the original “Geosoft Dent” accessories only
(see section 3).
!Do not disassemble or modify the product. Violation of the device
integrity cancels the warranty.
!Avoid letting any liquid inside the product’s housing.
!Do not use the device close to flammable agents. The device is not
suitable for use in presence of flammable anesthetic agents with air,
oxygen or nitric oxide.
! Use cleaned and disinfected parts of the device only. Cleaning and
disinfection must be conducted directly before the initial use and also
between each patient use to avoid cross infection (for more details see
section 7).
!To avoid overheating and failure of the working tips of BLUE and
RED type the total continuous work period of the emitter should not
exceed 10 minutes.
!The light emission generated by the photoactivator when working
with tips such as BLUE and RED is dangerous for your vision. In
order to avoid direct and reflected emission from the light source
entering the eyes of the dentist, patient, and auxiliary personnel during
operation, the following should be done:
- to use special protective glasses with orange lenses for working with
the tips of BLUE type or the sunglasses for working with tips of RED
type.
- to switch on the photoactivator only in the patient oral cavity.
!The light emission generated by the photoactivator when working
with the tip of LUMI type is completely non-hazardous for your
vision at brief influence. Nevertheless, the following safety measures
should be adhered during operation:
- do not direct the light into the eyes of the dentist or patient,
- turn on the photoactivator only in the patient's oral cavity.

9
ESTUS LIGHT
www.geosoft.ru/en
! This device requires special measures application for
electromagnetic capability (EMC) and should be installed and put into
operation accordingly with the information in the Appendix of the
User Manual. It includes the requirement not to use the device close to
daylight lamps, radio transmitting equipment and remote controls.
! Dysfunction of the device operation is possible if used in
electromagnetic interference (EMI) area. Do not use the device close
to the electromagnetic equipment. This equipment is usually marked
by the sign.
!Do not use the device jointly with the different equipment or as a
part of the equipment, not included into the manufacturer’s product
list.
!Do not use the accessories, adapters and cables, different from the
listed below. It can direct to the emission interference increase or
reduce interference immunity of the device. The Manufacturer
guarantees electromagnetic compatibility of the following accessories:
the charger cable of the maximal length 1.8 m.
! The device operates normally at a temperature of 10-35°С, relative
humidity of air not more than 80%, atmospheric pressure (101±3) kPa.
Any violation of these restrictions may cause the device error.

10
USER’S MANUAL
www.geosoft.ru/en
2. DELIVERY SET
Control unit “Estus Light” - 1 pc
Battery unit - 1 pc
Polymerizing tip “ESTUS LED-BLUE” - 1 pc
Tip “ESTUS - FULL BLUE”* - 1 pc
Tip “ESTUS LED-ORANGE”* - 1 pc
Tip “ESTUS LED-RED 630”* - 1 pc
Tip “ESTUS LED-RED 660”* - 1 pc
Tip “ESTUS LED-LUMI”* - 1 pc
Tip “ESTUS-BLUE POINT”* - 1 pc
Stand “Estus One-B”*- 1 pc
Сharging stand “Estus Energy-S”*- 1 pc
Charger cable USB - USB-B*- 1 pc
Power adapter (USB-socket) 1А*- 1 pc
User’s manual - 1 pc
Warranty Card “Estus Light” - 1 pc
Warranty Card “Estus Energy-S/D”* - 1 pc
Package - 1 pc
* These components are supplied if necessary

11
ESTUS LIGHT
www.geosoft.ru/en
3. ACCESSORIES
Tip “ESTUS LED-BLUE”
GE99.223.000
Polymerizing tip.
Blue light (440-475 nm).
Lens diameter - 9,5 mm
Tip “ESTUS LED-ORANGE”
GE99.152.000
Diagnostic tip.
Orange light (585-595 nm).
Lens diameter - 9,5 mm
Tip “ESTUS LED-RED 630”
GE99.153.000
Therapeutic tip.
Red light (peak 630 nm).
Lens diameter - 9,5 mm
Tip “ESTUS LED-RED 660”
GE99.196.000
Therapeutic tip.
Dark-red light (peak 660 nm).
Lens diameter - 9,5 mm
Tip “ESTUS LED-LUMI”
GE99.219.000
Diagnostic tip.
UV emission (peak 405 nm).
Lens diameter - 9,5 mm

12
USER’S MANUAL
www.geosoft.ru/en
Tip “ESTUS-BLUE POINT”
GE99.220.000
Polymerizing point tip.
Blue light (440-475 nm).
Lens diameter - 9,5 mm
Tip “ESTUS– FULL BLUE”
GE99.221.000
Polymerizing tip.
UV light (400-420 нм) +Blue light (440-475nm)
Lens diameter - 9,5 mm
Seal ring for the handpiece (3 pcs)
GE99.183.000
Additional silicon sealing ring for all types of the
tips.
Battery unit GE99.205.000
Additional battery unit for the “Estus Light”
handpiece (2х3.7 V,800mАh)
Control unit “Estus Multi (Plus)”
GE28.000.000
External apex locator and control unit for the
expended setting and the working parameters
displaying.
Power adapter (USB-socket) 1А
Model: Robiton USB1000/White
Input voltage - (100-240) V, ~50/60 Hz
Output voltage - 5 V; 1А.

13
ESTUS LIGHT
www.geosoft.ru/en
! Accessories are delivered separately, additionally paid
Charging stand “Estus Energy-S”
GE42.000.000 One-port charging stand for the
battery unit of the “Estus Light” handpiece.
Charging stand “Estus Energy-D”
GE39.000.000 Two-ports charging stand for two
battery units of the “Estus Light” handpiece.
Stand “Estus One-B” GE99.208.000
Single-stand for the “Estus Light” handpiece.
Stand “Estus Two-B” GE99.209.000
Double stand for all handpieces from “Estus” series

14
USER’S MANUAL
www.geosoft.ru/en
4. “ESTUS LIGHT” APPEARANCE
“Estus Light” appearance is on the figure 1
B
1
2
4
3
5
7
6
D
E
10
9
8 C
Figure 1. “Estus Light”
A

15
ESTUS LIGHT
www.geosoft.ru/en
Table 1. Variants of using the ring switch
А. Handpiece “Estus Light”:
1. Control unit.
2. Tip (of BLUE, RED, ORANGE or LUMI type).
3. Removable battery unit.
4. Control ring switch (see table1).
5. STATUS indicator (see table 2).
6. LED scale of the 4 indicators to display the chosen working mode.
7. Discharge indicator of the removable battery unit.
B. Stand “Estus One-B” for the handpiece.
C. Charging stand “Estus Energy-S”:
8. Charging socket.
9. Charge indicator.
10. Socket USB-B for the charger cable;
D. Charger cable USB- USB-B
E. Power adapter (USB-socket)
Power Press ring switch Result
OFF. 1 time Power on
Holding up to 10 sec. Volume adjustment
Holding > 20 sec. Pair creating mode activation
ON
1 time Emitter On / Off
2 times Working mode choosing
2 times with holding
3 times Power off
3 times with holding Return to the factory settings

16
USER’S MANUAL
www.geosoft.ru/en
Table 2. STATUS indicator variants
5. TECHNICAL SPECIFICATIONS
5.1. “Estus Light” handpiece:
Power supply - Li-Ро battery unit (2х3,7 V; 800 mАh).
Electric shock protection - Device with the built-in power supply.
Working part is of the Вtype.
The built-in radio module NF-03: frequency range - 2,4-2,525GHz,
max output capacity - 7 dBm (0,00501W), cover range -up to 3m in
the direct vision.
Performance duration with the new fully charged battery unit
without boost charge - is not less than 500 emitting cycles in «Н»
mode.
STATUS indication color Meaning
WHITE No tip connection
WHITE
blinking
Activation of the pair creation mode or
a warning that the current settings are different
from the factory settings
(changed by the user).
BLUE Tip of the BLUE type is connected.
RED Tip of the RED type is connected.
ORANGE “ESTUS LED - ORANGE” tip is connected
LILAC “ESTUS LED - LUMI” tip is connected

17
ESTUS LIGHT
www.geosoft.ru/en
Table 3
Stand-by operating time to automatic switch off - is 10 ±0,5 min.
Battery unit charging time - 70 ±10 min.
Battery resource - is not less than 300 recharges.
The working area of the ring switch on the front side of the
handpiece - 180°
The operating force of the ring switch - not more than 1N
Audio indication parameters: audio frequency - from 1 to 6 kHz,
volume level - not more than 70 dB.
Dust and water protection rate - IP41.
Dimensions - (215*33*43) ±3 mm
Tip (lens) working diameter - 9,5 mm
Weight - 95 ±10 g
Service time of the device - 5 years.
Parameters Parameters
factory
settings
Values when
Estus-Multi Plus* using
with the tip of BLUE type:
Light source:
- ESTUS - FULL BLUE*
- ESTUS LED - BLUE”
- ESTUS - BLUE POINT*
LED UV + 2 LED BLUE
3 LED BLUE;
LED BLUE;
Emission spectrum, nm
- ESTUS - FULL BLUE*
- ESTUS LED - BLUE
- ESTUS -BLUE POINT*
400-420, 440-475
440-475
440-475
Light intensity in modes with
accuracy ±20%, mW/cm2
Н=2500,
М=1500,
L=1000
Н=2500, М=1500,
L=1000, = from 500
to 2500, step 500

18
USER’S MANUAL
www.geosoft.ru/en
Parameters Parameters
factory
settings
Values when
Estus-Multi (Plus)* using
Exposure time
in modes, ±1 sec.
Н=5,М=10,
L=20
Н=5, М=10, L=20,
= from 5 to 20, step 5
Norm, Soft, Pulse functions
in modes.
Н/М/L= only
Soft
Н/М/L= only Soft
= Norm, Soft, Pulse
with the tip of RED* type:
Light source:
- ESTUS LED - RED 630
- ESTUS LED - RED 660
2 LED RED
2 LED DEEP RED
Emission spectrum, nm
- ESTUS LED - RED 630
- ESTUS LED - RED 660
620-645 (peak 630)
650-670 (peak 660)
Light intensity in modes
with accuracy ±20%, mW/
cm2
Н=1000,
М=800,
L=600
Н=1000, М=800, L=600,
= from 300 to 1500,
step 100
Exposure time
in modes, ±1 sec.
Н=30, М=60,
L=90
Н=30, М=60, L=90,
= from 30 to 90, step
10
with “ESTUS LED- ORANGE”* tip:
Light source: LED AMBER
Emission spectrum, nm
Light brightness in modes, #
of level
Н=9, М=5,
L=1
Н=9, М=5, L=1,
= from 1 to 9, step 1
585-595

19
ESTUS LIGHT
www.geosoft.ru/en
5.2. Charging stand “Estus Energy-S”:
Power - 5V, 1А.
Electric shock protection - the product is of the class II.
Dust and water protection rate - IP41.
Dimensions - (87*56*49) ±3 mm
Weight - 130±10 g
Service time of the device - 5 years.
5.3. Power adapter (USB-socket) 1A
Input voltage - (100-240) V, ~50/60 Hz .
Output voltage - 5 V; 1А.
5.4. Stand “Estus One-B”:
Dimensions- (100*60*40) ±3 mm
Weight - 132 ±10 g
* not included into the delivery set, could be purchased separately, additionally paid.
Parameters Parameters
factory
settings
Values when
Estus-Multi (Plus)* using
with “ESTUS LED– LUMI”*tip:
Light source: LED UV
Emission spectrum, nm 400-420 (peak 405)
Light brightness in modes, #
of level
Н=9, М=5,
L=1
Н=9, М=5, L=1
= from 1 to 9, step 1

20
USER’S MANUAL
www.geosoft.ru/en
6. PREPARATORY STAGE AND
WORKING PROCEDURE
Step 1. Battery unit
charging
А) Disconnect the
battery unit from the
handpiece
B) Put the battery unit
into the charging socket
of the charging stand
“Estus Energy-S”
After transporting the device at the temperature less than + 5°C,
before use, keep it at the indoor temperature for 1 hour
if
< +5 °С
1 hour
at +25 °С
Other manuals for ESTUS
4
Table of contents
Other GEOSOFT DENT Dental Equipment manuals

GEOSOFT DENT
GEOSOFT DENT ESTUS User manual

GEOSOFT DENT
GEOSOFT DENT ENDOEST-MOTOR User manual

GEOSOFT DENT
GEOSOFT DENT ENDOEST-3D User manual

GEOSOFT DENT
GEOSOFT DENT ENDOEST MOTOR-MINI User manual

GEOSOFT DENT
GEOSOFT DENT DENT ENDOEST User manual

GEOSOFT DENT
GEOSOFT DENT ESTUS User manual

GEOSOFT DENT
GEOSOFT DENT EndoEst-Apex 02 User manual

GEOSOFT DENT
GEOSOFT DENT ENDOEST-3D User manual

GEOSOFT DENT
GEOSOFT DENT ESTUS User manual