GHM-Messtechnik PO User manual

GHM Messtechnik GmbH
●
Honsberg office
Tenter Weg 2-8
●
42897 Remscheid
●
Germany
Telephone +49 (0) 2191 9672-0
●
www.honsberg.com
1
Operating manual
for the flow indicators - rotor, inline structure and turbine: PO, WR1, FR, RM, HV
Table of contents
1General safety notes, usage ........................................................................................................ 1
1.1 Safety signs and symbols ........................................................................................................ 1
1.2 Safety notes............................................................................................................................. 2
1.3 Product liability and warranty................................................................................................... 2
1.4 Standards and guidelines ........................................................................................................ 2
2Product description ...................................................................................................................... 2
2.1 Active principle......................................................................................................................... 2
2.2 Product contents...................................................................................................................... 2
2.3 Appropriate usage ................................................................................................................... 2
3Structure of the devices................................................................................................................ 3
4Assembly and installation............................................................................................................. 3
4.1 Mechanical assembly............................................................................................................... 3
5Activation, operation and maintenance......................................................................................... 3
5.1 Activation................................................................................................................................. 3
5.2 Operation/maintenance............................................................................................................ 4
6Technical information................................................................................................................... 4
7Accessories.................................................................................................................................. 4
8Device transportation and storage................................................................................................ 4
9Return.......................................................................................................................................... 4
10 Disposal.................................................................................................................................... 4
11 Disclaimer................................................................................................................................. 4
This operating manual must be locally stored so that it can always be accessed.
All procedures described within this operating manual may only be performed by trained personnel
authorised by the operator with corresponding protective gear.
1.1 Safety signs and symbols
Danger signs and symbols are marked as noted below for this operating manual:
1 General safety notes, usage
Warning! Symbol warns of ensuing danger, death, grave bodily injury and/or severe
material damages due to carelessness.
Attention! Symbol warns of possible dangers or harmful situations that arise due to not
observing damage to the device and/or to the surroundings.
Note! Symbol refers to procedures that have an indirect influence on operation due to
carelessness, or which can trigger unforeseen reactions.

GHM Messtechnik GmbH
●
Honsberg office
Tenter Weg 2-8
●
42897 Remscheid
●
Germany
Telephone +49 (0) 2191 9672-0
●
www.honsberg.com
2
1.2 Safety notes
Read the product information before activating the device. Ensure that the product is
indefinitely suitable for the usage in question.
The operator is responsible for the error-free operation of the device. He is obligated to
determine and observe adherence to the required work and safety measures of the respectively valid
stipulations during the full duration of application.
1.3 Product liability and warranty
This operating manual contains the instructions for assembling and operating the device safely in the
stipulated manner. Should any difficulties arise that cannot be solved by using the operating manuals
and product information, additional information must be retrieved from the manufacturer. The
manufacturer reserves all rights to technical changes and improvements. Usage of this operating
manual requires the appropriate qualification of the user. The operating personnel is also subject to
the operating manual.
1.4 Standards and guidelines
Dependent on: RoHS - Guideline 2002/95/EC
Oftentimes, with applications, the necessity arises to ensure minimal care, e.g. with lubrication or
coolants. With the flow devices PO, WR1, FR, RM and HV a visual flow monitor of fluid media can be
facilitated. The rotor/turbine rotation visualizes the volume flow.
2.1 Active principle
Rotor
The liquid medium enters into the housing and takes the visible arranged rotor in rotation. The
frequency of the rotor allows a subjective evaluation of flow volume.
Turbine
The liquid medium enters into the housing and makes the turbine in rotation. The rotor turns in
proportion to the flow volume.
2.2 Product contents
Enclosed with the product are an operating manual and the corresponding product information.
To avoid any transportation damages, the devices are equipped with threaded plugs or protective
bags.
2.3 Appropriate usage
The flow indicator serves to visually monitor the flow of the medium. The device may only be
employed for the medium stated in the product information.
This product is intended for application in machinery and facilities and for the application of
media of the fluid group II as per Guideline 97/23/EC. The product does not fall under
Guideline 97/23/EC and also receives no CE label in accordance with this guideline. The stated limit
values may never be exceeded (the data can be found in the product information).
2 Product description

GHM Messtechnik GmbH
●
Honsberg office
Tenter Weg 2-8
●
42897 Remscheid
●
Germany
Telephone +49 (0) 2191 9672-0
●
www.honsberg.com
3
To ensure flawless usage of our devices, the following points must be observed during
assembly and installation:
4.1 Mechanical assembly
Take the appropriate measures to prevent freezing of the medium. Should the device later be
subjected to an ambient temperature <4°C, no operation with pure water may be performed.
Frost damage may be caused by water remaining in the device.
Note the permitted installation positions from the product information.
The device may never serve as a fixed point.
The connector flanges/threads must be compatible.
A filter should be provided for heavily spoiled media.
Take note of the stated operating pressure as well as the permissible temperature range.
Thermal expansion of the pipework must be balanced out by compensators.
The device can be aligned horizontally or vertically.
The direction of flow is indicated on the device by an arrow. The arrow points in the direction of
flow. With the HV device the flow in both directions is possible.
When tightening the screw joint the connection must be locked so that no torque is transferred to
the body.
This equipment is designed for low-viscosity media. Highly viscous medium delays the
start of rotor/turbine.
5.1 Activation
Before activation note the limit values stated in the product information, such as for pressure
stage, temperature range or maximum permitted flow.
If present, the transport lock must be removed.
When operating with protective covers, remove them immediately before assembly.
Rinse the pipe system before assembly to remove any spoiling.
Observe the direction of flow. This is indicated on the device with an arrow and must run parallel
to the pipe axis after assembly.
Properly tighten the device during assembly.
Endurance must be assessed with aggressive media.
To avoid heavy pressure surges we recommend that you fill and ventilate the system before
activation. Pressure surges may not exceed the value of PN/PS.
Ensure that assembly is conducted properly.
1
The device FH has no hatch/scaling.
3 Structure of the devices1
4 Assembly and installation
5 Activation, operation and maintenance
Connectio
n outfeed
side
Figure 1: Schematic diagram of the devices PO/WR1/FR/RM und HV
PO/WR1/FR/RM
Body
Rotor
Sight glass
HV
Connection
Connection
Turbine
Sight glass
Connection

GHM Messtechnik GmbH
●
Honsberg office
Tenter Weg 2-8
●
42897 Remscheid
●
Germany
Telephone +49 (0) 2191 9672-0
●
www.honsberg.com
4
5.2 Operation/maintenance
The devices operate with pure medium free of repairs. We recommend applying a filter for unclean
medium. With the device WR1 there is the additional possibility to clean the sight glass with an
internal wiper.
The technical information can be found in the product information. This is included with
the product or may be downloaded at http://www.ghm-messtechnik.de/en/products/b-
sensors-and-instrumentation/b2-flow/rotor-inline-model.html#c4558.
Filter TYPE ZV
Filter TYPE ZE
Storage
Please observe the storage temperature.
A desiccant or heating against the formation of condensation is recommended in moist areas.
Transport
Please observe the transportation temperature.
Prevent environmental influences such as impacts, blows, dust and vibrations.
The legal regulations for protecting the environment and our personnel require that returned
devices which have come into contact with toxic and hazardous materials can be treated
with no risks to personnel and the environment.
Should you return a device to us for evaluation, repair or disposal we ask that you strictly adhere to
the following regulation:
A return form can be downloaded on our homepage at:
http://www.ghm-messtechnik.de/en/downloads/ghm-forms.html.
Acceptance from GHM-Honsberg can only occur if
1. a filled-out form is provided with each return,
2. packing is applied that prevents damage to the device,
3. the device is cleaned so that no dangers are present,
4. the filled-out form and, if necessary (hazardous materials), a safety data sheet of the
measurement medium is applied to the outside of the packaging.
During disposal, a material separation and recycling of the device components as well as the
packaging must be observed. The legal stipulations and guidelines valid at this point in time must be
adhered to.
The device may not be disposed of in a residual waste bin. Should a disposal of the device take
place, send it directly to us with the return form filled out under point 9. We take over the appropriate
and professional disposal.
© GHM-Messtechnik GmbH, Remscheid
As of: 2014-09-04
2
More information on our accessories can be found in the product information.
3
See product information: ambient/transportation temperature
6 Technical information
7 Accessories2
8 Device transportation and storage3
9 Return
10 Disposal
11 Disclaimer
All rights reserved, including those pertaining to translation. No portion of this
operating manual may be reproduced, duplicated or distributed without
permission from the company GHM Messtechnik in Remscheid.
Changes reserved.
This manual suits for next models
4
Table of contents
Other GHM-Messtechnik Measuring Instrument manuals

GHM-Messtechnik
GHM-Messtechnik GREISINGER GTF 111-Ex Series User manual

GHM-Messtechnik
GHM-Messtechnik GFTB 200 User manual

GHM-Messtechnik
GHM-Messtechnik GREISINGER GMH 3181 Series User manual

GHM-Messtechnik
GHM-Messtechnik GREISINGER GMH 3611 User manual

GHM-Messtechnik
GHM-Messtechnik GMH 3851 ab User manual

GHM-Messtechnik
GHM-Messtechnik TA 888 N User manual