Gianni MCS-3H-KB02 User manual

Dip Switch
Mounting Screws
(2 pcs.)
Connector
Potentiometer
(Sensitivity Volume) Radar
Cover
Indicator LED




 Mounting
Template Installation
Instruction cable Mounting Screws
(2 pcs.)
Mounting height of
4.0m (13.15ft) or lower
4.0m
(13.15ft)
Ensure there are no moving
objects in the detection areas Ensure no condensation gets
onto the sensor
Avoid heavy rain and snow If possible ensure no
accumulation of snow or water
on the floor
The Radar part of the MCS-3H-
KB02 sensor may be negatively
influenced by metal close to or
in the detection area
Center area Right area
Microwave Sensor MCS-3H-KB02
1. Overview 5. Installation Instructions
2. Dimensions
3. Specifications
Operation Manual
Standby
Initializing
Detecting
Change of DIP Switch




75mm(2.95”)=Standard Mounting Pitch
155mm (6.10”)
40mm (1.56”) 35mm (1.37”)
43mm (1.69”)
60mm (2.36”)


 
!"
# $%
# 

# 
 
& 
'
( Specifications may change without notice.
4.0〔m〕(13.15〔ft〕Max
12~24 VAC/DC
<2W (VA)
Doppler method: (moving body detection)
24.20 〔GHz〕
0.5 〔seconds〕App.
Form C Relay DC50〔V〕0.1〔A〕Resistor Load
-20℃~+60℃(-4℉~140℉)
Below 80%
Depth Detection: +15~51 (MAX 54)
Adjust the left and right: Left 15 (MAX 30) Right: 15 (MAX 30)
0.24 〔lb.〕(0.11〔Kg〕)
4. Mounting Precautions
'(( )#( Drilling may cause electric shock. Be careful of hidden
wires inside the automatic door operator cover.
Attach the template at the
mounting position.
1Drill mounting (3.5mmø)
and wiring (10mmø) holes.
2Remove the sensor cover as
illustrated
Lift the sensor cover.
Flat screw
Slit in base
driver
3
Attach the sensor with the screws.
4Door Controller Wiring
Red
Black
White
Yellow
Green
AC/DC
12 to 24〔V〕±10%
COM
N.O.
N.C.
Power
(Non Pole)
5
House connectors in the
space provided.
6Replace cover.
7※Removing the cover after
installation
Flat
screwdriver
Push
Pull
Push
Pull
1
7
2
1
2
6. Adjusting Sensitivity
Turn the potentiometer clockwise to increase the sensor sensitivity.
Turn the potentiometer counterclockwise to decrease the sensor sensitivity when
there is nothing in the detection area.
Sensitivity Volume
H
L
7. Adjusting Detection Area Width and Depth
Detection Area Adjustment
※Detection area varies depending on walking speed
※Adjustment as illustrated below
Left
Right
Far
Near
Radar
Please do not touch
the surface
Installation height “2.2m”and Sensitivity set to“High”.
〔m〕
2.0 1.0 0 1.0 2.0
1.0
2.0
3.0
4.0
〔27 degree〕setting
〔42 degree〕setting
〔54 degree〕setting
Left area
Copyright © All Rights Reserved. P-MU-MCS-3H-KB02 Published: 2019.10.16
Input
)#(
= Default Setting
* !
ON
OFF
1
2
Direction
Detection
Relay
Output
!
When set to ON, pedestrians moving away from the
sensor will not be detected.
Refer to 〔9. Timing Chart of Events〕for full details
on Ouput
OFF
1
ON
1
OFF
ON
2
Output (Mechanical Relay)
Dip Switch
NO
12

Dip Switch
Relay Output POWER OFF
OFF
ON
2
White
Yellow
Green
White
Yellow
Green
White
Yellow
Green
White
Yellow
Green
White
Yellow
Green
White
Yellow
Green
NON-DETECTION DETECTION
< Disclaimer> The manufacturer cannot be held responsible for below.
1. Misinterpretation of the installation instructions, miss connection, negligence, sensor modificaion and inappropriate installation.
2. Damage caused by inappropriate transportation.
3. Accidents or damages caused by fire, pollution, abnormal voltage, earthquake, thunderstorm, wind, floods and other acts of providence.
4. Losses of business profits, business interruptions, business information losses and other financial looses caused by using the sensor or malfuction of the sensor.
5. Anount of compensation beyond selling price in all cases.
8. DIP Switch Settings
Copyright © All Rights Reserved. P-MU-MCS-3H-KB02 Published: 2019.10.16
9. Timing Chart of Events
+

Popular Accessories manuals by other brands

Quincy lab 140AE-1 operating manual

Quincy lab

Quincy lab 140AE-1 operating manual

HomePro ZIR000 user manual

HomePro

HomePro ZIR000 user manual

DOL 20SCR Technical user guide

DOL

DOL 20SCR Technical user guide

RAB Smart Task installation manual

RAB

RAB Smart Task installation manual

Kemppi KMS 300 quick guide

Kemppi

Kemppi KMS 300 quick guide

Stearns 57,500 Series Installation and service instructions

Stearns

Stearns 57,500 Series Installation and service instructions

iGuzzini TWILIGHT COPENAGHEN manual

iGuzzini

iGuzzini TWILIGHT COPENAGHEN manual

Adelaide Annexe & Canvas Avan Deluxe installation guide

Adelaide Annexe & Canvas

Adelaide Annexe & Canvas Avan Deluxe installation guide

OHAUS 5000 instruction manual

OHAUS

OHAUS 5000 instruction manual

HOME8 WLS1300 quick start guide

HOME8

HOME8 WLS1300 quick start guide

MAXBOTIX MaxSonar quick start guide

MAXBOTIX

MAXBOTIX MaxSonar quick start guide

ioSmart iSmart56 Installation and user guide

ioSmart

ioSmart iSmart56 Installation and user guide

Focusrite Scarlett 18i8 user guide

Focusrite

Focusrite Scarlett 18i8 user guide

Velleman ED38105 user manual

Velleman

Velleman ED38105 user manual

JumpSport SkyBounce user manual

JumpSport

JumpSport SkyBounce user manual

Prima-Temp PRIYA Instructions for use

Prima-Temp

Prima-Temp PRIYA Instructions for use

Tefcold BC85I-BC85I W user manual

Tefcold

Tefcold BC85I-BC85I W user manual

Vaisala WMS302 user guide

Vaisala

Vaisala WMS302 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.