Gianni DG-15LD User manual

LED Indicators & Keypad Sounds
Operation Instruction
Jumper Setting
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
Blue On
Green On
Amber On
1 Beep
2 Beeps
3 Beeps
5 Beeps
Power on, Stand by
Relay 1 active
Relay 2 active
Valid key press
Enter, exit setting mode
Incorrect operation
Master Code back to 12345
(Cleared settings)
5 digit
4 or 5 digit setting
4 digit
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
Blue + Green + Amber Programming mode
RESET
4OR5 Normal
Reset
1. Default value: “1234” for 4 digits, “12345” for 5 digits
It’s suggested to clear all stored codes prior to new setting.
2. Master Code reset to default value”12345”:
3. Clear all PINs:
Specifications
12-key keypad (0~9,*,#)
3 LED indicators display
(Power: Blue, Relay 1: Green, Relay 2: Amber)
1 Contact for Request-To-Exit button
1 Contact for door reed switch
Non-volatile memory protects programmed information in
case of power loss.
EPROM
Memory Volume
Output
Input
LED Status Indication
Keypad
Ambient Humidity
Operating Temperature
0%~95% (Non-condensing)
-20ºC~+70ºC
2 relays (Dry contacts: N.O./N.C./Com.)
01~99 seconds or Toggle Mode (00)
Relay 1 is controlled by user *001~*200(*300)
Relay 2 is controlled by user *201~*210(*301)
Sign: Relay1(*300); Relay2(*301)
12~24 VDC
Relay Electric Current 3A/120VDC , 3A/24VDC
Operating Voltage
Current Draw Active: 90mA/12VDC, Standby: 40mA/12VDC
Active: 120mA/24VDC, Standby: 60mA/24VDC
Relay Strike Time
200+10 PINs (*001~*210)
Digital Keypad Operation Manual
LED
Beep
Master Code reset to
default value"12345"
a. Insert the jumper into 1-2 (5 beeps)
b. Master Code reset to default value
c. Insert the jumper into 2-3
a. Reset Master Code to default value (5 beeps, clearing all PINs)
b. Insert the jumper into 2-3
a - Enter Programming Mode
Enter the master code twice (Default value: “1234” or “12345) to enter programming
mode (2 beeps)
Note: 1. After 60 seconds if no data entered, the keypad will automatically exit the
programming mode.
2. The controller will be locked for 60 seconds upon 30 consecutive wrong master
code entries.
79mm
125mm
55mm
64mm
DG-15LD
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25 Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
b - Add New PINs
1. Enter programming mode.
2. Enter slot position *001~*210.
3. Enter the PINs (1 beep).
4. Repeat, or press “#” to exit programming mode.
Relay 1 is controlled by the slot position *001~*200.
Relay 2 is controlled by the slot position *201~*210.
Note: “00000”, “1234”, “12345” and master code cannot be used as PINs.
c - Set Relay Output Time
1. Enter programming mode.
2. Press *300 (or *301).
3. Press 05 (01~99) (1 beep).
Press 05 will set the SSR to 5 seconds. Set toggle mode by pressing “00”.
4. Press “#” to exit programming mode.
Note: In Toggle mode, the Relay will switch between N.C. contact and N.O. contact by
entering PIN once.
d - Delete PINs
1. Enter programming mode.
2. Press *006 (if *006 slot position is to be deleted).
3. Press 0000 (or 00000) (1 beep).
4. Press “#” to exit programming mode.
e - Change Master Code
1. Enter programming mode.
2. Press*00.
3. Enter new master code (1 beep).
4. Press “#” to exit programming mode.
f - Turning Buzzer Function ON/Off (In setting mode)
1. Enter Master code twice (2 beeps).
2. Enter *400 (1 beep).
3. Enter 0 (buzzer on) or 1 (buzzer o) (1 beep)
4. Press “#” to exit programming mode.
g - Delete Multiple PINs
1. Enter Master code twice (2 beeps).
2. Enter *800 (1 beep).
3. Press the rst slot position to be deleted (e.g. 006, 1 beep).
4. Press the second slot position to be deleted (e.g. 208, 1 beep).
5. Press “#” to exit programming multiple PINs or press # again to exit programming mode.
h - Resetting Keypad
1. Enter Master code twice (2 beeps).
2. Enter *900 (1 beep).
3. Enter 0 (master code is restored to 1234 or 12345) or enter 1
(all parameters are restored to default settings; Relay 1 & 2 users are deleted)
(5 beeps, and the keypad exit programming mode automatically)
Wiring Diagram
Fail-secure
Fail-safe
12VDC IN+
IN-
N.O.1
COM.1
N.C.1
PB
PB
Relay1
Relay2
REED
For Relay 2, door opening time is set to 00
(toggle mode).
4 or 5 Reset
N.O.2
COM.2
N.C.2
REED
REED
Relay1
Relay2
IN+
IN-
N.O.1
COM.1
N.C.1
PB
PB
N.O.2
COM.2
N.C.2
REED
REED
4 or 5 Reset
12VDC
REED
Power Supply
Dry
Contact
Dry
Contact
Power Supply
Electric Lock
Fail-Secure Mode
(Must install a varistor )
Varistor
N.C. contact output: opened status
N.O. contact output: closed status
N.C. contact output: opened status
N.O. contact output: closed status
Electric Lock
Fail-Secure Mode
(Must install a varistor )
Blue
Green
Yellow
Brown
Brown
Blue
Green
Yellow
Brown
Brown
For Relay 2, door opening time is set to 00
(toggle mode).
Varistor
Copyright All Rights Reserved. P-MU-DG-15LD Published:2020.11.25
Note:
Additional input for anti-tailgating function to ensure high security access control
(for Relay 2 only). The function is unavailable for Toggle Mode (00).
Warranty
The product is warranted against defects in material and workmanship while used in
normal service for a period of 1 year from the date of sale to the original customer. The
GEM policy is one of continual development and improvement; therefore GEM reserves
the right to change specications without notice.
* The door strike or Relay must have a diode or varistor across the door strike terminals
to suppress the back EMF of the strike – failure to do so will damage the Relay contacts
and electronic components, or even burns the controller.



Other Gianni Keypad manuals

Gianni DG-15 User manual

Gianni

Gianni DG-15 User manual

Gianni DG-160 User manual

Gianni

Gianni DG-160 User manual

Gianni DG-187 User manual

Gianni

Gianni DG-187 User manual

Gianni DG-900 CiTiPROX User manual

Gianni

Gianni DG-900 CiTiPROX User manual

Gianni DG-20 User manual

Gianni

Gianni DG-20 User manual

Popular Keypad manuals by other brands

Dynex DX-KEYPAD Quick setup guide

Dynex

Dynex DX-KEYPAD Quick setup guide

Ness M1 Navigator user manual

Ness

Ness M1 Navigator user manual

aikron A20-3V Operation manual

aikron

aikron A20-3V Operation manual

Spidertracks Spider X Keypad user manual

Spidertracks

Spidertracks Spider X Keypad user manual

Blink Marine PKP2600SI CANopen user manual

Blink Marine

Blink Marine PKP2600SI CANopen user manual

Risco lightsys RP432KP user manual

Risco

Risco lightsys RP432KP user manual

Interlogix NX1192E installation manual

Interlogix

Interlogix NX1192E installation manual

SHORE TEL BB424 user guide

SHORE TEL

SHORE TEL BB424 user guide

Nortek 212iLW? 242iLW Installation & programming manual

Nortek

Nortek 212iLW? 242iLW Installation & programming manual

SECO-LARM SK3133-PPQ installation manual

SECO-LARM

SECO-LARM SK3133-PPQ installation manual

Linear 2GIG-PAD3-433 Install instructions

Linear

Linear 2GIG-PAD3-433 Install instructions

Beninca IRI.KPAD quick guide

Beninca

Beninca IRI.KPAD quick guide

Genie Wireless Keypad-IC Installation and programming instructions

Genie

Genie Wireless Keypad-IC Installation and programming instructions

Fortrek SPIDER VENOM 2 GK705BK Configuration guide

Fortrek

Fortrek SPIDER VENOM 2 GK705BK Configuration guide

Pakton JVA PTE0240 manual

Pakton

Pakton JVA PTE0240 manual

SI Sidekick installation instructions

SI

SI Sidekick installation instructions

Bosch D7212G Operation and installation guide

Bosch

Bosch D7212G Operation and installation guide

GE NetworX NX-1500E user manual

GE

GE NetworX NX-1500E user manual