Unit: (mm)
ANSI standard faceplate can mount Optional SMB-101 back case for surface mount.
directly into electrical box for flush mount.
I. Features
1. Two-In-One MIFARE & FeliCa compatible proximity reader
2. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up
to 0.5 second
3. Access modes:
a. Only Proximity Card〈default setting〉b. PIN or Proximity Card c. PIN + Proximity Card
4. Logical memory prevents duplicated card setting
5. Lockout Function: The controller will lockout for 60 seconds after entering 5 times invalid PINs or
cards. (The keypad without beep sound during the period time)
6. Controller with keypad sound to avoid incorrect key-in
7. Additional input for anti-tailgating function to ensure high security access control
8. Non-volatile memory stores all code settings for a long time, even in the event of total power
failure
9. Dual relays to control door lock and other security devices
II. Specifications
Operating Voltage 12VDC
Current Draw Pull-In: 60mA/12VDC
Holding: 40mA/12VDC
RF Frequency MIFARE(13.56MHz) & FeliCa(13.56MHz)
Read Range 5~7cm (In noise-free environment)
Keypad 12-digit (0~9,*,#)
Input 2 contacts for Request-to-exit button, 1 contact for door reed switch
Output 2 relays (N.O./N.C./Com. Dry Contact)
LED Status Indication 3 LED indicators display (Green/Yellow/Red)
Memory Volume 1000+10 Proximity cards/tokens + PINs
Relay Electric Current Max. 1A/30VDC; 0.3A/125VAC; 0.3A/110VDC
Relay Strike Time 01~99 seconds or Toggle Mode(00)
Ambient Humidity 5%~95% (Non-condensing)
Operating Temperature -20°C~70°C
Copyright All Rights Reserved.
P-MU-DG-900 Ver.D Publish: 2010.08.23 Page: - 1 -/ 6

Copyright All Rights Reserved.
P-MU-DG-900 Ver. D Publish: 2010.08.23 Page: - 2 -/ 6
III. Indicator Status & Default Setting Parameters
Beep & LED Indication
Mode Signal Status
Yellow (Slow Flash) Power on, Standby
Green On Valid entry, first relay active
Standby
Red On Second relay active, invalid card/PIN
Yellow (Rapid Flash) Enter programming mode
Green On (Rapid Flash)
Green Stay On
The slot position of Relay 1 is available.
The slot position of Relay 1 is unavailable.
LED
Programming
Red On (Rapid Flash)
Red Stay On
The slot position of Relay 2 is available.
The slot position of Relay 2 is unavailable.
1 Beep Valid card, key press, enter programming mode
Standby
4 Beeps Invalid card, incorrect PIN
1 Beep Input data is correct, exit programming mode
Beep
Programming
3 Beeps Input data incorrect, other incorrect operation, duplicated
card settings
Factory Default Setting
Access Mode Proximity Card Only
Format All Bits
Card Storage (MAX. 1000+10 pcs) None
Master Code 12345 (5 digits)
Alarm Functions (All) Function disabled
Relay Strike Time (Time Delay Setting) 1 second
Pressed Key Time Delay 5 seconds (Fixed)
Programming Mode Time Delay 25 seconds (Fixed)

Copyright All Rights Reserved.
P-MU-DG-900 Ver. D Publish: 2010.08.23 Page: - 3 -/ 6
IV. Wiring Diagram
(MUST INSTALL A DIODE)
(MUST INSTALL A VARISTOR)
(VARISTOR)
VaristorDiode
Note:
1. It is suggested to use a linear power supply unit to prevent reading range reduction at the card reader.
2. It is suggested to use #22~26 AWG insulation wire.
3. Exit button is at N.O. contact.
4. With CE qualified EMC specification.
5. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress
the back EMF of the strike - failure to do so will damage the relay contacts and electronic components,
or even burns the controller.

Copyright All Rights Reserved.
P-MU-DG-900 Ver. D Publish: 2010.08.23 Page: - 4 -/ 6
V. Operation Instruction
1. Master Code
The master code comprises of a five-digit number and is used to access programming functions of the
digital keypad and cannot be used for access i.e. It cannot be the same as other PINs. The default
master code is set to 12345. Under normal operation the keypad is used for entering PIN to gain
access. In the programming mode the keypad can be used to add/delete PINs, set relay strike time
and other operation functions.
2. Enter Programming Mode
Press the master code twice (12345 12345) to enter programming mode (1 beep, Yellow LED flash).
3. Setting the Access Mode
The dual authentication feature allows the keypad to be programmed to grant access optionally with
either Proximity Card only, or PIN or Proximity Card and PIN.
1. Enter programming mode
2.Press*0
3.Press00 (1 beep, Yellow LED stay on) for Proximity Card Only
Press01 (1 beep, Yellow LED stay on) for Proximity Card or PIN
Press02 (1 beep, Yellow LED stay on) for Proximity Card + PIN
4.Press#(1 beep) back to programming mode
5.Press#again (1 beep) back to standby mode (Yellow LED slow flash)
4. Setting the Relay Strike Time
The relay strike time determines the amount of time that the door remains unlocked after a valid
proximity card or PIN is entered. NOTE: For both Relay 1 & Relay 2, enter 00 will set the relay
strike time to 0 second (relay set to toggle mode).
1. Enter programming mode
2.Press*1for Relay 1 (rapid Green LED flash) →Enter 00~99 (1 beep, Green LED stay on)
Press*5 for Relay 2 (rapid Red LED flash) →Enter 00~99 (1 beep, Red LED stay on)
3.Press#(1 beep) back to programming mode
4.Press# again (1 beep) back to standby mode (Yellow LED slow flash)
5. Clear Memory of All Proximity Cards and PINs
1. Enter programming mode
2.Press*8(all 3 LEDs rapid flash)
3.Press88 (all 3 LEDs stay on, 1 long beep indicating data successfully deleted)
4.Press#(1 beep) back to programming mode
5. Press #again (1 beep) back to standby mode (slow Yellow LED flash)
6. Reset Controller Parameter to Default Value
1. Enter programming
2. Press*8(all 3 LEDs rapid flash)
3. Press 99 (all 3 LEDs stay on, 1 long beep indicating data successfully deleted)
4
.Press#(1 beep) back to programming mode
5.Press# again (1 beep) back to standby mode (Yellow LED slow flash)

Copyright All Rights Reserved.
P-MU-DG-900 Ver. D Publish: 2010.08.23 Page: - 5 -/ 6
7. Adding a Proximity Card and PIN to Relay 1
a.
1. Enter programming mode to select slot position 000~999 (Green LED rapid flash to indicate the
slot position is available)
2. Read new card (1 beep), then press 5-digit PIN 99999 (1 beep, Green LED stay on)
3. Press #(1 beep) back to programming mode
4. Press #again (1 beep) back to standby mode (Yellow LED slow flash)
NOTE: Master codes must NOT be the same as PIN codes.
b.
1. Enter programming mode to select slot position 000~999 (Green LED stay on to indicate the
slot position is unavailable
2.Press**(1 beep) to delete the data from the slot position (Green LED rapid flash)
3. Repeat the steps of 7-a to add new cards.
8. Adding a Proximity Card and PIN to Relay 2
a.
1. Enter programming mode
2. Press*4to select slot position 00~09 (Red LED rapid flash to indicate the slot position is
available)
3. Read new card (1 beep, Red LED stay on)
4.Press# (1 beep) back to programming mode
5.Press# again (1 beep) back to standby mode (Yellow LED slow flash)
b.
1. Enter programming mode
2.Press*4to select slot position 00~09 (Red LED stay on to indicate the slot position is
unavailable)
3.Enter**(1 beep) to delete the data from the slot position (Red LED rapid flash)
4. Repeat the steps of 8-a to add new cards.
9. Change Master Code
1. Enter programming mode
2.Press*3, then enter 5-digit master code twice e.g. 45678 45678 (1 beep, Yellow LED stay on)
3.Press# (1 beep) back to programming mode
4.Press# again (1 beep) back to standby mode (Yellow LED slow flash)
10. Add a New Master Card to Relay 1
a.
1. Enter programming mode
2.Press*7(rapid Green LED flash to indicate the controller without master card stored)
3. Read new card to set as master card (1 beep, Green LED stay on)
4.Press# (1 beep) back to programming mode
5.Press# (1 beep) back to standby mode (Yellow LED slow flash)
b.
1. Enter programming mode
2.Press*7 (Green LED stay on to indicate the master card had been stored)
3.Press**(1 beep) to delete the master card (Green LED rapid flash)
4. Repeat the steps of 10-a to add new master cards.
11. Add New Cards by Master Card
1. Read master card once (1 beep, Yellow LED rapid flash)
2. Enter slot position 001~999 (rapid Green LED flash to indicate the slot position is available)
3. Read new card (1 beep), then enter 5-digit PIN 99999 (1 beep, Green LED stay on)
4. Read master card again, reader back to standby mode (Yellow LED slow flash)
12. Reset the Master Code to Default Value
1. Turn off the power
2.Press# continuously, and energized (1 beep), the master code is reset to default value.

Copyright All Rights Reserved.
P-MU-DG-900 Ver. D Publish: 2010.08.23 Page: - 6 -/ 6
Warranty:
The product is warranted against defects in material and workmanship while used in normal service for
a period of 1 year from the date of sale to the original customer. The GEM policy is one of continual
development and improvement; therefore GEM reserves the right to change specifications without
notice.
Annex: User List
User User Name Slot Number Card #/ PIN #
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
Table of contents
Other Gianni Keypad manuals