Turbo Laser Repair Instructions
1) Remove the rubber cap (12) from the discharge casing (1).
2) Using a 27mm boxed end wrench unscrew drive plug (11) from discharge casing
(1).
3) Using a wooden dowel press out (2-9) from the top side of discharge casing (1).
4) Replaceitems2-10withpartsfromkit.Makesureitem8rstintothetabofitem2.
5) Replace rubber cap (12). Tighten drive plug (11) into discharge casing (1). Softly
shake assembly to ensure the parts freely move (see diagram below).
Turbo Laser Operating Instructions
Warning: Never put your hand in the rotating water blast. Always wear eye
protection. Never aim the blast at people or animals. Never aim the blast at live
electical appliances.
WARNING: This product might contain a chemical known to the State of California to
cause cancer, and birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov
Giant Industries, Inc.
900 N. Westwood Ave.
Toledo, Ohio 43607
PHONE: 419-531-4600
FAX: 419-531-6836
www.giantpumps.com
© Copyright 2021 Giant Industries, Inc.
01/21 22700.INDD
Correct Rotor Position Incorrect Rotor Position