GILBARCO VEEDER-ROOT NC3L Instruction Manual

NC3L
71A8462520GB
E03 03/05/2022
Verifone 12”

NC3L Verifone 12" - Installation and maintenance
ii
COPYRIGHT
The information included in this manual is subject to change depending on the evolution of the product; the
user shall be taken care of verify the release before use it.
Gilbarco Italia S.r.l. shall not be liable for incidental or consequential damages resulting from the improper
use of the products, or arising from installation, repair, maintenance by anyone other than authorized
personnel, or from usage of non-original spare parts, improper maintenance or alteration, accident, misuse,
abuse and neglect.
You may not copy or reproduce this manual for any purpose or transfer it to another party without prior
written authorization of Gilbarco Italia S.r.l.
Within this document "Gilbarco Italia S.r.l." could be hereinafter referred to as "Gilbarco".
© Copyright 2022 Gilbarco Italia S.r.l. All rights reserved
Gilbarco Italia S.r.l. Via de’ Cattani 220/G 50145 FIRENZE –ITALY

NC3L Verifone 12" - Installation and maintenance
iii
RE MA RKS
These symbols indicate that this product is not to be disposed of with common household
waste, according to the WEEE Directive (2012/19/EU).
This product should be handed over to a designated collection point, e.g., on an
authorized one-for-one basis or to an authorized collection site for recycling waste
electrical and electronic equipment (EEE) and batteries and accumulators.
Improper handling of this type of waste could have a possible impact on the environment
and human health due to potentially hazardous substances that are generally associated
with EEE. Your cooperation in the correct disposal of this product will contribute to the
effective usage of natural resources. For more information about the recycling of this
product, please contact your local city office, waste authority, approved scheme or your
household waste disposal service.
NOTE
This equipment is generally used in Petrol Stations, so it has been evaluated together the dispenser whose it
is a part and it is suitable to be used when properly installed and maintained following the provisions of this
manual.
Please observe that the pictures in this manual show a general version of crind and fuel dispenser, details in
the delivered model may differ.

NC3L Verifone 12" - Installation and maintenance
iv
WA R NING
WARNING
THE UNIT BEING THE SUBJECT-MATTER OF THIS MANUAL SHALL BE
INSTALLED AND COMMISSIONED BY TRAINED PERSONNEL
Trained personnel mean people with the appropriate technical education and
experience required to:
- carry out operations in areas accessible by technical assistance staff,
- be aware of the dangers involved in carrying out the operations and be instructed
about the measures required to minimise those dangers.
This equipment contains batteries and/or non-rechargeable batteries. This indicates
that these batteries shall be replaced and disposed only by trained personnel
certificated by Gilbarco.
Disposal of the equipment involves the battery removal in accordance with the
provisions laid following the instructions supplied by trained personnel certificated by
Gilbarco.
DISCLAIMER
The equipment installed and put into service following the instructions given in this
manual, will operate fully covering the characteristics described here.
Installation and put into service of the equipment in different way from the
instructions given in this manual, but that have followed the local laws, rules and
requirements for installations in Petrol Service Stations and have followed the
provisions about the safety disconnection devices given at chapter “Electrical
Installation” are generally allowed, but the performance may be affected.
DANGER
Before performing any electrical operation make sure that all devices have been
disconnected from the mains power.
Before performing any electrical installing/uninstalling operations, make sure that
also supply lines are isolated from mains by safety disconnection devices.
WARNING
The equipment shall be installed into an electrical system complying with the plant
engineering regulations in force and equipped at least with a 2-pole, 6A, C curve,
MCB differential for each supply line.
The electrical cables used for connections shall comply with the plant engineering
regulations in force, depending on the installation conditions (e.g. indoor or outdoor
underground, in cable duct, etc.) and they shall meet any functional characteristics
prescribed by Gilbarco.
WARNING
This equipment is not suitable for use in areas where children are likely to be
present.
This model of equipment is typically designed for commercial or industrial
environments whose installation is foreseen in premises where only adults are
normally present.
NOTE
Gilbarco declines all responsibility for any damages to property and/or persons due to
incorrect installation of equipment, incorrect connections or changes made to the
equipment, as well as for damages due to connections with other devices not
described in this manual.

NC3L Verifone 12" - Installation and maintenance
v
TA BL E OF CONTENTS
COPYRIGHT ...................................................................... I
REMARKS .......................................................................III
NOTE ............................................................................III
WARNING ....................................................................... IV
1. DEFINITION ............................................................... 7
2. TERMINAL OVERVIEW .................................................. 9
3. DIMENSIONS ............................................................ 11
4. WEIGHT ................................................................... 11
5. UNPACKING .............................................................. 12
6. PLACEMENT .............................................................. 13
7. INSTALLATION .......................................................... 15
7.1. MEC HANICA L INSTALLAT ION .................................... 16
7.2. ELEC TRIC AL INS TAL LAT IO N ..................................... 21

NC3L Verifone 12" - Installation and maintenance
vi
8. NC3L POWER -ON PROCEDURE FOR TEMPERATURES LOWER
THAN 0 °C ............................................................... 26
9. TBSP2 BOAR D ........................................................... 27
9.1. FUSES ................................................................. 28
10. COMPONENTS AND MAINTENANCE ................................. 29
10.2. CONTA CTLES S CAR D READE R UX400 ................... 35
10.3. PINPAD ......................................................... 37
10.4. RECEI PT PRINTER ............................................ 38
10.5. DISP LAY CLEAN ING .......................................... 46
10.6. BARC ODE RE ADER CLEA NING ............................. 47
10.7. KEYP AD CLEA NING ........................................... 47
10.8. CLEAN ING EXTERNA L ....................................... 48

NC3L Verifone 12" - Installation and maintenance
7
1. DEFINITION
NC3L Verifone 12” (Nordic Card 3 Landscape) is a payment terminal designed for card payment only, can
be installed on dispenser.
"Terminal representation could be slightly different due to different optional or customization”
NC3L Verifone 12”is equipped with:
•12” display module
•Verifone card reader model UX300
•Verifone contactless card reader UX400 (optional)
•Verifone pinpad model UX110
•Custom Printer TG2460HIII-EJ
•Barcode Reader Honeywell n5600 (optional)

NC3L Verifone 12" - Installation and maintenance
8
It is available single sided or double sided.
Double sided version has the two sides with specular layout, where printer panel and display panels are
swapped.
Single side is available with layout “A”or with layout ”B”, in this case the other side has a closed panel

NC3L Verifone 12" - Installation and maintenance
9
2. TE R MINAL OVERVIEW
NC3L Verifone 12”
"Terminal representation could be slightly different due to different optional or customization”
PART
DESCRIPTION
1
Cabinet
2
Display/pinpad door
3
Display touch
4
Verifone pinpad
5
Barcode reader
6
Cable pass through
7
Printer/card reader door
8
Lock
9
Contact Card reader
10
Contactless card reader
11
Receipt printer

NC3L Verifone 12" - Installation and maintenance
10
"Terminal representation could be slightly different due to different optional or customization”
PART
DESCRIPTION
11
Verifone card reader
12
Printer paper roll
13
Receipt printer
14
Key lock
15
Display cover
16
Display unit
17
Alarm opened door switch
18
Supply board CRDI
19
Heating unit
20
Fixing keyhole shaped holes
21
Cable pass through
22
Cable pass through cover
23
Cash button terminal block
24
Cash button (side B) cable
25
AC mains cable
26
Cash button (side A) cable
27
Ethernet cable(s)
28
External fan
29
External fan cover

NC3L Verifone 12" - Installation and maintenance
11
3. DIME NSIONS
4. WE I GHT
NC3L Verifone 12”……………………………………………………………………………………………............ 50 kg

NC3L Verifone 12" - Installation and maintenance
12
5. UNPACKING

NC3L Verifone 12" - Installation and maintenance
13
6. PL ACEME NT
The placement of NC3L is flexible and requires only little space since all operative actions are carried out
from the front. Required space in front of the terminal is shown in previous paragraphs.
NC3L it is mounted directly on fuel dispenser and is available with different version of reader/printer panel to
fit on the following dispensers:
Gilbarco SK700 phase II
Dresser Wayne Global Star 3/4 slope

NC3L Verifone 12" - Installation and maintenance
14
Dresser Wayne Global Star 3/4 square
Dresser Wayne Global Star 5 slope
Dresser Wayne Global Star 5 square

NC3L Verifone 12" - Installation and maintenance
15
7. IN S TAL LATI ON
The installation shall be performed in accordance with security regulations for service stations, issued by
responsible authorities.
All the operations must be done after disconnecting all supply lines and following all suitable procedures to
operate in explosion hazardous areas.
Before installation check that the intended location meets this requirement.
Warning
Installation operations are allowed only when safety
conditions are put in place.
Disconnect all supply lines before starting the
installation.
WARNING: terminals do NOT have a safety switch, but such shall be installed in the electrical power centre
a MCB differential for each supply line at least with a 2-pole, 6A, C curve characteristic, if not included in the
dispenser power supply line(s).
The terminal shall not be modified without written permission from Gilbarco, otherwise the manufacturer’s
product liability will be voided.
Interference is prevented by installing power a
nd communications cables in separate cable ducts.
Remove scrap cables from cable manholes.
WARNING: before first device switching on, please refer to Chapter #5 “NC3L power-on procedure for
temperatures lower than 0 °C”.

NC3L Verifone 12" - Installation and maintenance
16
7 . 1 . M E C H A N I C A L I N S T A L L A T I O N
1. Open the computer head doors, the computer head side and bottom panel, the airing panel and the two
side pumps panels; also remove the cable pass through cover (part #21) on the NC3L terminal.
2. Pull out all the cables from the inside of the dispenser column to let them pass around of the NC3L
terminal.
3. Mount the small size airing panel fastening the screws.

NC3L Verifone 12" - Installation and maintenance
17
4. Fasten for half length the four M6 screws on the dispenser computer head thread.
If there is any fixing thread available, fasten the screws with four M6 hexagonal nuts.
WARNING
Risk of tipping over.
High center of gravity.
Some lifts may require two persons.

NC3L Verifone 12" - Installation and maintenance
18
5. Insert the four screws head in the keyhole shaped holes of NC3L terminal pushing it upward (1) and then
moving it toward the column (2).
6. Open the reader/printer unit’s front doors (opening the keyhole cover and turning the key 90° clockwise).

NC3L Verifone 12" - Installation and maintenance
19
WARNING
Risk of crushing / pinch hazard.
Open the doors gently.
Avoid placing fingers or hands between
the doors when they are moving.
7. Open the pinpad/display unit’s doors.
Turn the key inside the reader/printer unit, on left top, 90° clockwise and pull the safety lever.
8. Check the NC3L terminal is lined up with the dispenser head.
Tighten up the four screws inside the NC3L terminal.

NC3L Verifone 12" - Installation and maintenance
20
9. For each terminal side follow this sequence: insert additional two M6 screws with grower washers and
nuts inside the computer head, then tighten up.
Table of contents
Popular Touch Terminal manuals by other brands

Speaka Professional
Speaka Professional A148192 Important information

National Instruments
National Instruments NI TB-2641 installation instructions

Mitsubishi
Mitsubishi GOT1000 GT15 user manual

Genexis
Genexis FiberTwist Series installation guide

Zte
Zte WF720 user manual

Ingenico
Ingenico WebPOS iWP220 user guide