Giovenzana FGR2 User manual

Strawinskylaan 1105
1077 XX Amsterdam, The Netherlands
INTRODUCTION .................................2
Terms of use....................................2
Special conditions for a safe usage.................2
TECHNICAL CHARACTERISTICS ................... 3
Technical data ..................................3
Microswitch technical data........................3
Main components ...............................4
Dimensions.....................................5
INSTALLATION ..................................6
Limit switch installation ..........................6
Limit switch wiring...............................8
Microswitches wiring.............................9
Ground wiring ...................................9
Cams adjustment...............................10
ACCESSORIES / SPARE PARTS ...................11
Pinions (PA66 - water cutting) ....................11
Pinions (PA66 - molded) .........................12
Camshapes....................................13
Oldham coupling ...............................14
Optional flange installation.......................15
MAINTENANCE AND REPAIR TERMS
AND CONDITIONS ..............................16
Maintenance...................................16
CERTIFICATIONS ...............................16
FGR2
EN
instruction manual
MT-FGR2-EN / 28.06.2021
Rev. 4
ROTARY GEAR LIMIT SWITCH
Before use, read this booklet carefully to
acquaint yourself with the features of the
product. This booklet is an integral part of
the product and therefore must be kept until
the product is dismissed.
Giovenzana International B.V. reserves the
right to change the features and data shown
in this document at any time and without
notice. This document cannot therefore be
considered a contract with third parties.
Rotary gear limit switches FGR are designed
and manufactured according to IEC
international standard and EN European
regulations.
Any improper installation or any tampering
of the device may cause serious personnel
injury or property damage, therefore, the
installation and maintenance must be
performed by specialized and authorized
personnel.
The use of this device is not allowed in
environment with a potentially explosive
atmosphere or in presence of corrosive
substances and in salt spray.
They are suitable for use in industrial
environment with machinery monitoring and
protection purpose.
Available in 2 variations:
• base fixing
• rear shaft
Front fixing with optional flange available.

2GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
INTRODUCTION
Terms of use
Special conditions for a safe usage
GIOVENZANA INTERNATIONAL B.V.
Terms of use
Special conditions for a safe usage
The FGR rotary gear limit switch is a device used to
control the number of turns or the rotation/direction
angle of industrial and building machines.
A typical application is the rolling shutter door,
overhead cranes or tackles etc. The unit, throught a
gear system and cams transmission, controls 2 or
more microswitches so, after a determined number of
revolutions, it can prepare the motor to start or stop run.
The microswitches have a calibration screw that
operates independently on each cam; so it can calibrate
the opening and closing of each micro according the
functional requirements needed.
The system gear transmission allows you to choose
different ratios with the main shaft.
The equipment must be installed only if it is completely
intact and unbroken. The product must be installed
according to the applicable code of practice, national
regulations and laws and / or international standards as
well as in compliance with the present instructions.
Do not change anything inside or outside the
equipment.
Low mechanical risk
The equipment is suitable for resisting impact energies
up to 4 J.
When impacts of energy are likely greater than 4 J,
additional mechanical protection is required around the
plastic case.
Potential electrostatic risk
The equipment is intended for fixed use and the user
must not frequently touch the equipment in service
(except for maintenance).
To avoid the potential electrostatic charge, it is
necessary to perform the following instructions during
the installation and service of the FGR:
• Do not install under direct air or other gas flow. If
these requirements cannot be met, additional external
direct flow protection is required.
• Install only when the relative humidity of the
environment is greater than 30% (stable, always or
for a long time) or in an environment with a humidity
control system.
• The metal parts of the casing must be connected
to the equipotential system in accordance with the
instructions in paragraph “Connection of earthing or
bonding conductors”.
• Do not rub the plastic cover insistently. If cleaning is
required (e.g. to remove dust) only manual operations
with wet materials are allowed.
Conditions
• The inner components (cam MFI micros, mounting
brackets, etc.) are mounted in order to guarantee the
type of protection.
• Any modification is forbidden.
• Do not remove any components or micro even if they
are not used.
Types of protection
• Every screw shall be tightened with the tightening
torque according to this document, to maintain the
degree of protection IP.
• Additional holes and/or entries into enclosure are
forbidden, the only entries in the enclosure shall be
made by Giovenzana (see the information reported in
clause 1 of this document).
• The type of protection and minimum degree of
protection (IP code) of the entries into enclosure
or cable glands shall be in accordance with the
equipment marking.
• Any entry of the enclosure, the mounting of the entries
into enclosure or cable glands shall be carried out to
maintain the level of protection of the equipment.
Connection of earthing or bonding conductors
The equipment shall be earthed in accordance with the
relevant code of practice. The equipment is provided by
internal connection terminal for earthing.
If the reference standards applicable for the installation
require an external equipotential connection or these
become necessary for other reasons, connect the
equipotential conductor to the external earth terminal,
identified with the earthing symbol.
The conductors used for the earth and equipotential
connection must be equipped with an eye lug. Install
each conductor according to the following instructions:
• Place the eyelet in contact with the threaded hole of
the internal or external earth terminal, positioned on
the metal box.
• Place a Grover washer or non-loosening washer
between the eye lug and the clamp screw.
• Tighten the ground terminal screw with a tightening
torque of 1.7 N×m (15 lb×in). On the internal earth
screw add some threadlocker. Tightening the screw
ensures electrical continuity.
INTRODUCTION
GIOVENZANA INTERNATIONAL B.V.
Terms of use
Special conditions for a safe usage
The FGR rotary gear limit switch is a device used to
control the number of turns or the rotation/direction
angle of industrial and building machines.
A typical application is the rolling shutter door,
overhead cranes or tackles etc. The unit, throught a
gear system and cams transmission, controls 2 or
more microswitches so, after a determined number of
revolutions, it can prepare the motor to start or stop run.
The microswitches have a calibration screw that
operates independently on each cam; so it can calibrate
the opening and closing of each micro according the
functional requirements needed.
The system gear transmission allows you to choose
different ratios with the main shaft.
The equipment must be installed only if it is completely
intact and unbroken. The product must be installed
according to the applicable code of practice, national
regulations and laws and / or international standards as
well as in compliance with the present instructions.
Do not change anything inside or outside the
equipment.
Low mechanical risk
The equipment is suitable for resisting impact energies
up to 4 J.
When impacts of energy are likely greater than 4 J,
additional mechanical protection is required around the
plastic case.
Potential electrostatic risk
The equipment is intended for fixed use and the user
must not frequently touch the equipment in service
(except for maintenance).
To avoid the potential electrostatic charge, it is
necessary to perform the following instructions during
the installation and service of the FGR:
• Do not install under direct air or other gas flow. If
these requirements cannot be met, additional external
direct flow protection is required.
• Install only when the relative humidity of the
environment is greater than 30% (stable, always or
for a long time) or in an environment with a humidity
control system.
• The metal parts of the casing must be connected
to the equipotential system in accordance with the
instructions in paragraph “Connection of earthing or
bonding conductors”.
• Do not rub the plastic cover insistently. If cleaning is
required (e.g. to remove dust) only manual operations
with wet materials are allowed.
Conditions
• The inner components (cam MFI micros, mounting
brackets, etc.) are mounted in order to guarantee the
type of protection.
• Any modification is forbidden.
• Do not remove any components or micro even if they
are not used.
Types of protection
• Every screw shall be tightened with the tightening
torque according to this document, to maintain the
degree of protection IP.
• Additional holes and/or entries into enclosure are
forbidden, the only entries in the enclosure shall be
made by Giovenzana (see the information reported in
clause 1 of this document).
• The type of protection and minimum degree of
protection (IP code) of the entries into enclosure
or cable glands shall be in accordance with the
equipment marking.
• Any entry of the enclosure, the mounting of the entries
into enclosure or cable glands shall be carried out to
maintain the level of protection of the equipment.
Connection of earthing or bonding conductors
The equipment shall be earthed in accordance with the
relevant code of practice. The equipment is provided by
internal connection terminal for earthing.
If the reference standards applicable for the installation
require an external equipotential connection or these
become necessary for other reasons, connect the
equipotential conductor to the external earth terminal,
identified with the earthing symbol.
The conductors used for the earth and equipotential
connection must be equipped with an eye lug. Install
each conductor according to the following instructions:
• Place the eyelet in contact with the threaded hole of
the internal or external earth terminal, positioned on
the metal box.
• Place a Grover washer or non-loosening washer
between the eye lug and the clamp screw.
• Tighten the ground terminal screw with a tightening
torque of 1.7 N×m (15 lb×in). On the internal earth
screw add some threadlocker. Tightening the screw
ensures electrical continuity.
INTRODUCTION
GIOVENZANA INTERNATIONAL B.V.
Terms of use
Special conditions for a safe usage
The FGR rotary gear limit switch is a device used to
control the number of turns or the rotation/direction
angle of industrial and building machines.
A typical application is the rolling shutter door,
overhead cranes or tackles etc. The unit, throught a
gear system and cams transmission, controls 2 or
more microswitches so, after a determined number of
revolutions, it can prepare the motor to start or stop run.
The microswitches have a calibration screw that
operates independently on each cam; so it can calibrate
the opening and closing of each micro according the
functional requirements needed.
The system gear transmission allows you to choose
different ratios with the main shaft.
The equipment must be installed only if it is completely
intact and unbroken. The product must be installed
according to the applicable code of practice, national
regulations and laws and / or international standards as
well as in compliance with the present instructions.
Do not change anything inside or outside the
equipment.
Low mechanical risk
The equipment is suitable for resisting impact energies
up to 4 J.
When impacts of energy are likely greater than 4 J,
additional mechanical protection is required around the
plastic case.
Potential electrostatic risk
The equipment is intended for fixed use and the user
must not frequently touch the equipment in service
(except for maintenance).
To avoid the potential electrostatic charge, it is
necessary to perform the following instructions during
the installation and service of the FGR:
• Do not install under direct air or other gas flow. If
these requirements cannot be met, additional external
direct flow protection is required.
• Install only when the relative humidity of the
environment is greater than 30% (stable, always or
for a long time) or in an environment with a humidity
control system.
• The metal parts of the casing must be connected
to the equipotential system in accordance with the
instructions in paragraph “Connection of earthing or
bonding conductors”.
• Do not rub the plastic cover insistently. If cleaning is
required (e.g. to remove dust) only manual operations
with wet materials are allowed.
Conditions
•
The inner components (cam MFI micros, mounting
brackets, etc.) are mounted in order to guarantee the
type of protection.
•
Any modification is forbidden.
•
Do not remove any components or micro even if they
are not used.
Types of protection
•
Every screw shall be tightened with the tightening
torque according to this document, to maintain the
degree of protection IP.
•
Additional holes and/or entries into enclosure are
forbidden, the only entries in the enclosure shall be
made by Giovenzana (see the information reported in
clause 1 of this document).
•
The type of protection and minimum degree of
protection (IP code) of the entries into enclosure
or cable glands shall be in accordance with the
equipment marking.
•
Any entry of the enclosure, the mounting of the entries
into enclosure or cable glands shall be carried out to
maintain the level of protection of the equipment.
Connection of earthing or bonding conductors
The equipment shall be earthed in accordance with the
relevant code of practice. The equipment is provided by
internal connection terminal for earthing.
If the reference standards applicable for the installation
require an external equipotential connection or these
become necessary for other reasons, connect the
equipotential conductor to the external earth terminal,
identified with the earthing symbol.
The conductors used for the earth and equipotential
connection must be equipped with an eye lug. Install
each conductor according to the following instructions:
•
Place the eyelet in contact with the threaded hole of
the internal or external earth terminal, positioned on
the metal box.
•
Place a Grover washer or non-loosening washer
between the eye lug and the clamp screw.
•
Tighten the ground terminal screw with a tightening
torque of 1.7 N×m (15 lb×in). On the internal earth
screw add some threadlocker. Tightening the screw
ensures electrical continuity.
INTRODUCTION
GIOVENZANA INTERNATIONAL B.V.
Microswitch technical data
Operating temperature -25 ... +85°C
Minimum life expectancy mechanical
electrical
one million of cycles
half million of cycles
Rated thermal current Ith 8 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 1500 V
Rated operating current le resistive load
inductive load
8 A - 250 V
3 A - 250 V
Pollution degree 2
Protection against electric shock class II
Terminals
The microswitches installed can have one of the three types of terminals illustrated below:
6.3×0.8 faston screws M3 for wire 1.5 mm² screws M3 for wire 1.5 mm²
with plate protection

3GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
TECHNICAL CHARACTERISTICS
Technical data
Case - base: die-cast aluminum alloy
- cover: self-extinguishing thermoplastic material
Ratio -
Direct ratio 1:12 - 1:33 - 1:50 - 1:100 - 1:200
Protection class IP65
Shaft type - stainless steel mounted on ball bearings
- double overhang shaft version available
Fixing type base
Microswitches up to 6
Cam block self-lubricating with transparent support for easier cam viewing
Cable entry 2 × M20
Temperature - operating: -25 ... +70°C
- storage: -30 ... +70°C
Options - 3 cam shape options
- 20 pinion options
- front fixing (with optional flange)
Microswitch technical data
GIOVENZANA INTERNATIONAL B.V.
Microswitch technical data
Operating temperature -25 ... +85°C
Minimum life expectancy mechanical
electrical
one million of cycles
half million of cycles
Rated thermal current Ith 8 A
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 1500 V
Rated operating current le resistive load
inductive load
8 A - 250 V
3 A - 250 V
Pollution degree 2
Protection against electric shock class II
Terminals
The microswitches installed can have one of the three types of terminals illustrated below:
6.3×0.8 faston screws M3 for wire 1.5 mm² screws M3 for wire 1.5 mm²
with plate protection

4GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Main components
3
2
9
10
8
11
11
4
1
6
3
5
4
7
12
B
A
1 Cover
2 Base
3 Cover fixing screws
4 Holes for fixing the limit switch (M6)
5 Front shaft
6 Cable glands M20
7 Switch unit
8 Cams
9 Cam adjustment locking screw
10 Cam adjustment screws
11 Microswitches
12 Screw for earthing connection
A Flange for front fixing of the limit
switch (where provided)
B Double shaft (where provided)

5GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Dimensions
45
29
25 max
44 122
104.8
166
8.78.5
19.5
22
110
6149
22
19.5
Ø 12
90
(131.5)
Ø 4
10
90
65
(A)
10
7
(A)
45
29
25 max
44 122
104.8
166
8.7
7.5
8.5
110
6149
Ø 12
Ø 6
90
(131.5)
Ø 4
10
22
19.5
90
65
(A)
10
7
(A)
19.5
22
Base fixing
Rear shaft

6GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
90
65
INSTALLATION
Limit switch installation
Fixing points for basic configuration
45
29
25 max
44 122
104.8
15
166
8.78.5
14.529
25.125.1
110
6149
127.5
Ø 12
90
(131.5)
Ø 4
90
65
10
7
Ø 7
Ø 4.2
3.5
Ø 45
Ø 74
11
(A)
(B)
(B)
(A)
10
22
19.5
19.5
22
Front fixing with optional flange

7GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Fixing points for flanged configuration with optional flange
Base configuration fixing Flanged configuration fixing with optional flange
25.125.1
14.529
Ø 7 Ø 7
120°
Ø 60
Ø 74 Ø 74
120°
120°
3 × M62 × M6

8GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
GIOVENZANA INTERNATIONAL B.V.
Microswitches wiring
The FGR rotary gear limit switch can be equipped with 2 or more microswitches among those shown below.
The wiring of the microswitches can be carried out to obtain an NO contact, an NC contact or both.
NO NC
To wire the microswitches it is
necessary to use fastons suitable
for a 6.3×0.8 mm contact.
1
2
4
NO
1
2
4
NC
To wire the microswitches it is
necessary to strip the end of the
cable (1.5 mm²) and screw it
into the terminal (M3 screws).
1
2
4
NO
1
2
4
NC
To wire the microswitches it is
necessary to strip the end of the
cable (1.5 mm²) and screw it
into the terminal (M3 screws).
1
2
4
NO
1
2
4
NC
3b
3a
2a
2b
2c
Limit switch wiring
ATTENTION
The following procedures show an FGR limit switch
with 6 microwsitches but remain valid for any other
configuration.
ATTENTION
It is strictly forbidden to unscrew the
screws indicated in the figure. Their
removal can compromise the operation
of the limit switch and therefore cause
serious damages to things and people
during use.
2Remove the cable glands (a)
and loosen the sealing nuts (b)
to facilitate the insertion of the
cables (c).
3Insert the cables (a) into
the cable glands (b).
1b
1a
1Unscrew the 2 screws (a) and remove the cover (b).
4b
4c
4a
4Insert the cables (a) in the limit
switch (b) taking care not to let
the cable sheaths (c) protrude
too much.
ATTENTION
TO CARRY OUT THE FOLLOWING OPERATIONS, THE LIMIT
SWITCH COVER MUST BE REMOVED. ON THE COVER ARE
PLACED VERY IMPORTANT INFORMATION CONCERNING
THE LIMIT SWITCH YOU ARE INSTALLING. THE COVER
MUST BE REASSEMBLED ON THE CORRESPONDING BODY.
REASSEMBLING THE COVER ON A NON-CORRESPONDING
BODY CAN LEAD TO AN INCORRECT INTERPRETATION
OF THE LIMIT SWITCH OPERATION AND THEREFORE
CAUSING SERIOUS DAMAGE TO THINGS AND PEOPLE
DURING USE.

9GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Microswitches wiring
GIOVENZANA INTERNATIONAL B.V.
Microswitches wiring
The FGR rotary gear limit switch can be equipped with 2 or more microswitches among those shown below.
The wiring of the microswitches can be carried out to obtain an NO contact, an NC contact or both.
NO NC
To wire the microswitches it is
necessary to use fastons suitable
for a 6.3×0.8 mm contact.
1
2
4
NO 1
2
4
NC
To wire the microswitches it is
necessary to strip the end of the
cable (1.5 mm²) and screw it
into the terminal (M3 screws). 1
2
4
NO 1
2
4
NC
To wire the microswitches it is
necessary to strip the end of the
cable (1.5 mm²) and screw it
into the terminal (M3 screws). 1
2
4
NO 1
2
4
NC
2Finish the ground cable with a
cable lug (a) and fix everything
with the ground screw (b).
5a
5b
5Fix the cable glands (a) and then
tighten the sealing nuts (b).
Ground wiring
1
2a
2b
1Remove the ground fixing
screw.
TIGHTENING TORQUE
1.7 N×m / 15 lb×in

10GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
GIOVENZANA INTERNATIONAL B.V.
Pinions (PA66 - water-cut)
Z M Dp De Di a d L α
16020051 12 20 240 280 193.2 20 23.4 31.42 20°
16020052 17 14 238 266 205.24 14 16.38 21.99 20°
16020053 10 22 220 264 168.52 22 25.74 34.56 20°
16020054 12 18 216 252 173.88 18 21.06 28.27 20°
16020055 13 16 208 240 170.56 16 18.72 25.13 20°
16020056 17 10 170 190 146.6 10 11.7 15.71 20°
16020057 13 6 78 90 63.96 6 7.02 9.42 20°
16020070 16 19 304 336 266.56 16 18.72 25.13 20°
Z Number of teeth
M Diametral pitch
Dp Pitch circle diameter
De External diameter
Di Internal diameter
a Addendum
d Dedendum
L Tooth width
αPressure angle
1. Screw M6×16 + lock washer
Ø 4 mm
2. Elastic pin 4×24
1
2
Pinions thickness: 10 mm
For the installation of the water-cut pinions, the wheel coupling sleeve is required (code 16020050).
Ø 25
Ø 4
M4
26Ø 34
33
6Ø 12
H8
Ø 45
(*)
De
L
Dp
Di
Ø 3.8
(*)
Ø 34
Ø 24.6
Cams adjustment ATTENTION
The procedure implies that the FGR has already
been coupled to the gearmotor of the system to be
monitored.
2The cam pack shown in this procedure is equipped
with 6 microswitches (a). The correspondence
between calibration screws (b), cams (c) and
microswitches (a) is shown in the diagram.
3Loosen the main screw to release
the calibration mechanism.
4Adjust each cam (a) with the calibration screws (b).
The cam must rotate until the microswitch trips (c).
ATTENTION
The direction of rotation of the
calibration screw corresponds
to direction of rotation of the
cam.
1After having wired the limit switch (a) and connected
the cables to the microswitches (b) and to the ground
contact (c), proceed to adjust the cams as follows.
6Close the limit switch cover by
tightening the screws.
TIGHTENING TORQUE
1.6-1.8 N×m
14.2-15.9 lb×in
TIGHTENING TORQUE
1.8-2.2 N×m
16-19.5 lb×in
5At the end of the operation, tighten
the main screw to lock the calibration
mechanism.
1a
1b
1b
1c
2a
2a
2c
2b
M1
M3
M5
M2
M4
M6
C1
C2
C3
C4
C5
C6
34b
4a
4c
5
6

11GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
ACCESSORIES / SPARE PARTS
Pinions (PA66 - water cutting)
GIOVENZANA INTERNATIONAL B.V.
Pinions (PA66 - water-cut)
Z M Dp De Di a d L α
16020051 12 20 240 280 193.2 20 23.4 31.42 20°
16020052 17 14 238 266 205.24 14 16.38 21.99 20°
16020053 10 22 220 264 168.52 22 25.74 34.56 20°
16020054 12 18 216 252 173.88 18 21.06 28.27 20°
16020055 13 16 208 240 170.56 16 18.72 25.13 20°
16020056 17 10 170 190 146.6 10 11.7 15.71 20°
16020057 13 6 78 90 63.96 6 7.02 9.42 20°
16020070 16 19 304 336 266.56 16 18.72 25.13 20°
Z Number of teeth
M Diametral pitch
Dp Pitch circle diameter
De External diameter
Di Internal diameter
a Addendum
d Dedendum
L Tooth width
αPressure angle
1. Screw M6×16 + lock washer
Ø 4 mm
2. Elastic pin 4×24
1
2
Pinions thickness: 10 mm
For the installation of the water-cut pinions, the wheel coupling sleeve is required (code 16020050).
Ø 25
Ø 4
M4
26Ø 34
33
6Ø 12
H8
Ø 45
(*)
De
L
Dp
Di
Ø 3.8
(*)
Ø 34
Ø 24.6

12GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Pinions (PA66 - molded)
GIOVENZANA INTERNATIONAL B.V.
Pinions (PA66 - molded)
Z Number of teeth
M Diametral pitch
Dp Pitch circle diameter
De External diameter
Di Internal diameter
a Addendum
d Dedendum
L Tooth width
αPressure angle
Z M Dp De Di a d L α
16020058 8 20 160 200 113.2 20 23.4 31.42 20°
16020059 10 13 130 156 122.56 16 18.72 25.13 20°
16020060 12 12 144 168 121.716 12 14.04 18.85 20°
16020061 10 14 140 168 107.24 14 16.38 21.99 20°
16020062 10 12 120 144 91.92 12 14.04 18.85 20°
16020063 12 10 120 140 96.6 10 11.7 15.71 20°
16020064 12 8 96 112 77.28 8 9.36 12.57 20°
16020065 11 6 66 78 51.96 6 7.02 9.42 20°
16020066 12 5 60 70 48.3 5 5.85 7.85 20°
1
1. Elastic pin 4×24
No other accessories are required for the installation of the molded pinions.
(**)
De
Dp
Di
L
(**)
Ø 4
23
10
7
Ø 20
Ø 12+0.05

13GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Camshapes
GIOVENZANA INTERNATIONAL B.V.
Camshapes
Standard “A” (30°) “B” (15°) “C” (90°)
11703015 11703019 11703013
15 10.5 30
47.5° ±0.5° 28° ±0.5° 96° ±0.5°
For rotary gear limit switches with code FGR2... only
Material PA66
Standard “A” (25°) “B” (6°) “C” (90°)
11703030 11703031 11703032
13.5 730
38.5° ±0.5° 20° ±0.5° 93.5° ±0.5°
For rotary gear limit switches with code FGR2N... only

14GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Oldham coupling
GIOVENZANA INTERNATIONAL B.V.
Oldham coupling
Part number: FGH
• Oldham coupling
• Locking screw 4×40
• Spheres Ø 3 mm
* The hole on the coupling may not be present
Maximum axial disalignment obtained without locking
screw
1b
1a
2a
Ø 4 mm 2b
1b
1a
Ø 4 mm
1Position the two spheres (a) and the screw (b)
through the central hole and close with an Allen key.
2Make a hole (a), if not
present, and fasten with
the elastic pin (b).
1Make a hole (a), if not present, and fasten with the
elastic pin (b).
Assembly with locking screw Assembly without locking screw
102
7230
21
10
40
Ø 12
Ø 36
Ø 20
M8
Ø 3
Ø 4
13
13
A B
C
(18)
A B C

15GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Optional flange installation
1Remove the cap by unscrewing the 4 tightening
screws.
2Install the flange (a) with the 4
Allen screws (b).
1
2b
2a
TIGHTENING TORQUE
0.7-0.8 N×m / 6.2-7.1 lb×in
14.529
25.125.146.5
11
26.8
26.8
38.5
74
3.5
Ø 45
Ø 7
Ø 4.2

16GIOVENZANA INTERNATIONAL B.V. - MT-FGR2-EN / 28.06.2021 - Rev. 4
Maintenance
MAINTENANCE AND REPAIR TERMS AND CONDITIONS
GIOVENZANA INTERNATIONAL B.V.
Maintenance
Maintenance is required to guarantee the level of protection provided by the types of protection of this equipment.
Periodical verifications are required. The following operations shall be carried out with the frequency indicated in the
table.
Operation required Frequency Action
Check that the screws are in
place, free of corrosion.
Each time the enclosure is
opened and then closed
In case of fault contact
manufacturer for substitution
Check that the screws are
tightened with a correct torque.
Annually and each time the enclosure
is opened and then closed
Tight with the torque according
to this document.
Check the condition of the enclosure:
(enclosure is not damaged).
- Each time the enclosure is
opened and then closed.
- Annually.
- In case of impact.
In case of fault contact
manufacturer for substitution.
Check that the gaskets
- are not damaged.
- are placed correctly.
- the thickness is not compromised
by compression.
Each time the enclosure is
opened and then closed.
In case of fault contact
manufacturer for substitution.
Check if a dust layer is present
on upper and plane surfaces.
Depending on the frequency
of dust deposits.
Clean the surfaces periodically and
remove the dust layer. In case of
frequent deposit limiting the thickness
of the layer less than 5 mm.
Control the correct work of mircos. Annually if the usage is not
continuous (quarterly under
continuous use conditions h24).
To verify that the ratio of the
rotations set originally during
installation are maintained.
MAINTENANCE AND REPAIR TERMS AND CONDITIONS
CERTIFICATIONS
GIOVENZANA INTERNATIONAL B.V.
CERTIFICATIONS
Worm screw limit switches FGR series are in conformity with
the following standards or other normative documents:
EN 60947-1 2007/A1 : 2011/A2 : 2017
EN 60947-5-1 2004/A1 : 2009/AC : 2004/AC : 2005
EN 60204-1 2006/A1 : 2009
EN 60529 1991/A1 : 2000/A2 : 2013
EN 50581 2012
IEC 63000 2016
Markings
and therefore follow the provision of the
Directives:
2014/35/UE
2014/33/UE
2011/65/UE
2015/863/UE
Table of contents
Other Giovenzana Switch manuals
Popular Switch manuals by other brands

PHD
PHD JC1 Series Mounting instructions

Key Digital
Key Digital KD-X4x1WUTx operating instructions

ANTAIRA
ANTAIRA LNP-2602G-SFP Series Quick installation guide

Cisco
Cisco 3020 - Cisco Catalyst Blade Switch Command reference

TRBOnet
TRBOnet Swift Footswitch P001 user guide

Westermo
Westermo Lynx L106-S2 user guide