manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Giuliani Anello
  6. •
  7. Water Filtration System
  8. •
  9. Giuliani Anello 706 Series User manual

Giuliani Anello 706 Series User manual

FILTRO PER GAS
GAS FILTER
Mod.
706..
706.. F
Omologazione UNI-EN 126
UNI-EN 126 approved
In conformità alla Direttiva 97/23/CE
According to the 97/23/CE regulation
Previsto per articolo DN150.
Forseen for the DN150 model.
MOD. ABCDEHL
70611/CE Rp 1/2" 92 ---37 120
70612/CE Rp 3/4" 92 ---37 120
70602/CE Rp 1" 103 ---50 160
70604/CE Rp 1"1/4 103 ---50 160
70603/CE Rp 1"1/2 103 ---50 160
70631/CE Rp 2" 140 ---73 186
70603F/CE DN 40 -110 18 150 60 200
70631F/CE DN 50 -125 18 165 70 230
70610F/CE DN 65 -145 18 185 91 290
70620F/CE DN 80 -160 18 200 106 320
70640F/CE DN 100 -180 18 220 126 380
70660F/CE DN 150 -240 22 288 151 450
DATI TECNICI
Attacchi filettati: ……………..…………...……...Rp UNI-
ISO 7/1
Attacchi flangiati: …………………….....….ISO 7005/2 -
Pn 16
Pressione d'entrata Pmax.
-filtri filettati: ……………….. 1 bar (pressione di collaudo 2 bar)
-filtri flangiati: ……………… 4 bar (pressione di collaudo 6 bar)
Grado di filtrazione: …………………………...…….….. ≤50 µm
Temperatura d'impiego: …………….……….…… -10°C +80°C
Resistenza meccanica: ..………. secondo Norme UNI-EN 161
Materiali: corpo e coperchi in alluminio; elemento filtrante con
due pannelli in Viledon P15/500S omologato secondo le norme
DIN EN779, di lunga durata e con notevole assorbimento di
polvere; gabbietta per i filtri filettati in materiale sintetico, per i
filtri flangiati rinforzi in acciaio zincato.
Combustibili: gas delle tre famiglie: gas manifatturati (gas
città); gas naturali (gruppo H -metano); gas di petrolio liquefatto
(gpl); gas non aggressivi.
Caratteristiche costruttive: tutti i filtri flangiati sono provvisti di
raccordi per prese di pressione in entrata e in uscita.
TECHNICAL DATA
Threaded connections: ….……………...…….. Rp UNI-ISO 7/1
Flanged connections: …………………...… ISO 7005/2 -Pn 16
Maximun inlet pressure:
-threaded filters: ………………… 1 bar (testing pressure 2 bar)
-flanged filters: ………………….. 4 bar (testing pressure 6 bar)
Filtration degree: ……………………...………………… ≤50 µm
Working temperature: …………………...…..……. -10°C +80°C
Mechanical strength: ………....in compliance with UNI-EN 161
Materials: body and covers in aluminium. Filter element with
two long-life Viledon P15/500S panels with remarkable dust
absorption in according to DIN EN779 specifications; cage for
threaded filters in synthetic material; galvanized steel
reinforcements for flanged filters.
Fuels: gas of the following groups: manufactured gases (town
gas); natural gases (group H -methane); liquid petrol gas (lpg);
non aggressive gases.
Construction: all flanged filters are fitted with connections for
inlet or outlet pressure taps.
DIMENSIONI DI INGOMBRO (mm)
OVERALL DIMENSIONS (mm)
INSTALLAZIONE
Verificare che il filtro sia idoneo all’uso previsto e che tutti i dati
tecnici non siano superati.
Non installare il filtro a contatto con pareti intonacate.
Per il montaggio utilizzare appositi attrezzi ed agire sui mozzi
della filettatura.
Montare il filtro in modo tale che il coperchio sia in posizione
comoda per eventuali ispezioni o pulizie.
Fare attenzione che la direzione del flusso del gas sia quella
indicata sul filtro stesso.
Si può installare sia su tubazioni orizzontali che verticali.
MANUTENZIONE
Cambiare l’elemento filtrante se il ∆p fra i raccordi delle prese di
pressione è maggiore di 10 mbar; in ogni caso si consiglia di
cambiare l’elemento filtrante almeno una volta all’anno.
Per la sostituzione dell’elemento filtrante occorre:
1. interrompere l’afflusso del gas chiudendo il rubinetto di
intercettazione;
2. svitare le viti e togliere il coperchio;
3. togliere l’elemento filtrante e pulire accuratamente il vano
del filtro;
4. sostituire l’elemento filtrante con uno nuovo;
5. inserire il coperchio del filtro in modo che le guide all’interno
del coperchio stesso siano allineate con l’elemento filtrante,
quindi avvitare le viti;
6. controllare che non vi siano perdite di gas dal coperchio del
filtro.
INSTALLATION
Check that the filter suits the proper use and that all technical
data are not exceeded.
Do not install the filter on plastered walls.
To install the filter use suitable tools and operate on the
threading hubs.
Assemble the filter in such a way that the cover can be easily
removed for inspection or cleaning.
Ensure that the gas flow direction is that indicated on the filter.
It can be assembled both on horizontal and vertical piping.
MAINTENANCE
Change the filter element when ∆p between the pressure taps
connections exceeds 10 mbar; anyway it is recommended to
replace the filter element at least once a year.
To replace the filter element you need to:
1. cut off the gas flow by closing the cut off cock;
2. unscrew the screws and remove the cover;
3. remove the filter element and clean the filter housing
carefully;
4. replace the old filter element with a new one;
5. reassemble the filter cover ensuring that the guides inside
the cover are aligned with the filter element and then tight
the screws again;
6. check for any gas leak from the filter cover.
1 2 3 4 5 7 10 20 50 70 100 200 300 500 1000
5003002001007050403020101 2 43 5 7 1000
1 2 73 4 5 6 10 3020 40 10050 70 300200 500 1000
2
1
5
3
4
6
7
10
20
30
50
40
70
100
200
300
500
1000
0,1
0,2
0,3
0,4
0,5
0,7
1
2
3
4
5
7
10
30
15
20
Ediz. 03/02-A (K0050)
GIULIANI ANELLO S.r.l.
44042 CENTO (Ferrara –Italy) Via F.lli Bandiera, 8
Tel. (+39) 051901124 (4 linee r.a.) –Fax (+39) 051901405
Sito Web: www.giulianianello.it –Email: [email protected]
DIAGRAMMA PORTATE / PERDITE DI CARICO
DIAGRAM OF FLOW RATES / PRESSURE DROPS
1/2"
3/4"
1"
1"1/4
DN40
1"1/2
DN50
2"
DN65
DN80
DN100
DN150
Metano -Methane dv: 0,62
Gas città -Town gas dv: 0,45
Aria -Air dv: 1
G.P.L. -L.P.G. dv: 1,56
∆
p (mbar)
Q (m3/h)

This manual suits for next models

13

Popular Water Filtration System manuals by other brands

RAINSMART RainSmart user guide

RAINSMART

RAINSMART RainSmart user guide

Chungho NEW DIGITAL CHP-4010S user manual

Chungho

Chungho NEW DIGITAL CHP-4010S user manual

Aqua UF 3000 operating instructions

Aqua

Aqua UF 3000 operating instructions

KENT GEM Mineral RO Installation & operation manual

KENT

KENT GEM Mineral RO Installation & operation manual

Grizzly H3258 manual

Grizzly

Grizzly H3258 manual

Easymetal EASYRO 60 user manual

Easymetal

Easymetal EASYRO 60 user manual

SpectraPure MaxPure MPDI-90 GPD Installation and operating manual

SpectraPure

SpectraPure MaxPure MPDI-90 GPD Installation and operating manual

JRC NSVS675 manual

JRC

JRC NSVS675 manual

Waterdrop WD-TK user manual

Waterdrop

Waterdrop WD-TK user manual

Royal Prestige FrescaPure3500 FP3500 Use & care manual

Royal Prestige

Royal Prestige FrescaPure3500 FP3500 Use & care manual

Philips FC8044/02 user manual

Philips

Philips FC8044/02 user manual

Caen A3000NF Technical information manual

Caen

Caen A3000NF Technical information manual

Savio K5003 operating manual

Savio

Savio K5003 operating manual

Viesta AKF01 instruction manual

Viesta

Viesta AKF01 instruction manual

Frizzlife TF900 owner's manual

Frizzlife

Frizzlife TF900 owner's manual

Katadyn 8014931 user manual

Katadyn

Katadyn 8014931 user manual

APLOS R0-N5050 instruction manual

APLOS

APLOS R0-N5050 instruction manual

Hydac Filtromat OF5 C with FCU Operating and maintenance instructions

Hydac

Hydac Filtromat OF5 C with FCU Operating and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.