4.0 OPERATING INSTRUCTIONS
To operate your Cordreel:
• PULL OUT only the amount of shore power cord required to reach the outside power source.
• CONNECT your shore power cord to outside power source receptacle.
• TURN ON outside power supply.
When ready to get underway:
• TURN OFF outside power supply.
• DISCONNECT cord from the outside power supply.
• PUSH AND HOLD the Cordreel power switch (black rocker
switch). Cordreel will electrically retrieve the power cord and
store.
• When cord is fully retracted, RELEASE the power switch to
stop the unit. NOTE: Not releasing the switch may cause the
plug to get jammed in the unit and make the next use dicult.
5.0 MAINTENANCE
• TO RELIEVE ANY KINKING that may happen Rounely extend the power cable completely, stretch it on any at sur-
face, and allow the Cordreel to retract the cable into the reel.
• INSPECT ALL AC AND DC WIRING CONNECTIONS and make sure they are free of corrosion and connecons are
ght.
• INSPECT THE EXTERIOR JACKET of the power cable for nicks or cuts.
• IF YOUR POWER CABLE IS DIRTY, any cleaner should be compable with the outer jacket material of the power
cable.
• IF NEEDING TO REPLACE POWER CORDSET, USE ONLY 105⁰c (CRMA-30/32) of 90⁰C (CRM-16) MINIMUM RATED
CORDSETS and ensure that the outside diameter of the new cordset does not exceed that of the factory supplied
cordset.
6.0 TROUBLESHOOTING
ISSUE PROBABLE CAUSE RECOMMENDED ACTION
Non-funconal (either no power
or unit has power and does not
respond)
Tripped breaker
Blown fuse at power source
Power wire incorrectly connected
to power source
Defecve motor
Reset breaker
Replace fuse
Check power source fuse and connecons,
reconnect or replace if necessary
With power switch on and voltage across motor
wires
Cordreel stops retracng
while buon is being pushed
Cord jammed during retracon
causing breaker to trip
Reset breaker
Pay out cable and rewind
! CAUTION:
• Always disconnect AND fully retract
your cable BEFORE geng underway!
• Connuing to push power buon
aer cable is retracted may cause
damage to the motor and will cause
breaker switch to trip - reset before
next use.