Globus RF BEAUTY MINI User manual


2
Rev.10.15 - 22/10/2015

3
Rev.10.15 - 22/10/2015
DEAR CUSTOMER
THANK YOU FOR CHOOSING A GLOBUS PRODUCT. WE REMAIN AT YOUR DISPOSAL
FOR ANY ASSISTANCE OR ADVICE YOU MAY NEED
Devices for radio frequency “Rf Mini Beauty” are produced by
“Deess”
3/F, BuildingA GoldenPower Innovation and Technology Park,
Liuxian 2 road, Xin’an street, Bao’an district, Shenzhen,
Guangdong, China, 518101
Tel: +86-755-23832052/88322271 www.mydess.com
and distributed by:
Domino S.r.l.
Via Vittorio Veneto 52
31013 Codognè (Treviso) ITALY
Tel 0438.7933 Fax 0438.793363
www.globuscorporation.com

4
Rev.10.15 - 22/10/2015
TABLE OF CONTENTS
TECHNICAL FEATURES ..............................................................................................................5
Device...............................................................................................................................................5
EQUIPMENT...................................................................................................................................5
INTENDED USE .............................................................................................................................6
CONNECTIONS..............................................................................................................................6
Device...............................................................................................................................................6
LABELLING AND SYMBOLS......................................................................................................7
Device...............................................................................................................................................7
Interface and controls .......................................................................................................................8
Display..............................................................................................................................................8
WARNINGS AND CONTRAINDICATIONS................................................................................9
Mandatory behavior .........................................................................................................................9
Warnings before use.........................................................................................................................9
Warnings during the use...................................................................................................................9
Side effects .......................................................................................................................................9
Contraindications..............................................................................................................................9
MAINTENANCE AND CLEANING............................................................................................10
Device and accessories...................................................................................................................10
Transportation ................................................................................................................................11
Disposal..........................................................................................................................................11
INSTRUCTIONS FOR USE..........................................................................................................11

5
Rev.10.15 - 22/10/2015
TECHNICAL FEATURES
Device
Frequency: 1.15+0.1MHz
Protection level: IP 20
Size: 15.5 x 5.5 x 2.5 cm
Weight: 500 g
Power: 24 W
Mode: resistive
Conditions of use
Temperature: from +5°C to +40°C
Max. relative humidity: 80%
Atmospheric pressure: from 860 hPa to 1060 hPa
Power supply unit:
Model: KSAS0451200300D5
INPUT: 100-240 V~ 5060 Hz 1.2A
OUTPUT: 12V = 3.0A
Polarity:
Radio frequency gel: Globus, 250 ml
EQUIPMENT
A- Carrying case
B- Power supply unit
C- Device
1 conductive gel bottle
A
B
C

6
Rev.10.15 - 22/10/2015
A
When opening the package, please check that the basic equipment is complete.
If some elements should be missing, contact immediately your authorized retailer.
Control the integrity of the device and its accessories carefully.
The images are for illustrative purposes only. The manufacturer reserves the right to
make changes without prior notice.
INTENDED USE
The estimated useful life of the product is of 5 years. It is advisable to return the
device to the producer or authorized centre to perform security and maintenance
checks every two years.
Rf beauty mini is designed to be used in the following operating environments:
- domestic environment;
- for personal aesthetic use properly informed of the methodologies used by the
device.
CONNECTIONS
Device
"Rf beauty mini" has to be connected to the mains. To connect the power supply
unit to the connector, plug it as shown below.
First connect the cable to the device and then to the mains.

7
Rev.10.15 - 22/10/2015
LABELLING AND SYMBOLS
WEEE symbol (Waste of Electrical and Electronic Equipment). Recycling
symbol.
The WEEE symbol used for this product indicates that the device can’t be
treated as a household waste. Proper disposal of the product will
contribute to protect the environment. For more information on recycling
this product, please contact the office concerned of the local body, the
household waste management company or the store where the product
was purchased.
It indicates that this is a II class device
This symbol on your device indicates that it complies with the directives in
force
It indicates that the product has been produced respecting the directive
2011/65/EU
It informs the operator that before using the device he/she must read the
manual
It refers to the manufacturer
This symbol on your device indicates that it complies with the regulations
in force
Device

8
Rev.10.15 - 22/10/2015
Interface and controls
Display
SRT
05
Program
Power level
Treatment duration
Emission
Electrodes
Mode (M) button
ON-OFF button
LED light

9
Rev.10.15 - 22/10/2015
WARNINGS AND CONTRAINDICATIONS
Mandatory behavior
For safety reasons, the device must be used in the prescribed manner and within
the limits of use explained in this manual.
The manufacturer declines any responsibility due to a different use from what it is
indicated and prescribed in this manual.
No part of this manual (texts and/or photos) may be reproduced by electronic or
mechanical means without the prior written authorization of the manufacturer.
If the packaging, the cable or the connector of the power supply unit show signs
of wear or damage, the device should be immediately replaced.
The unit should be connected to the mains by its power supply unit. Before starting
the treatment, make sure that the power system specifications comply with the
directives in force in your country. Make sure that the power supply unit will be in a
comfortable position and that it will be easy to be removed.
Do not modify the device.
Warnings before use
Do not use this device simultaneously with other electronic devices, especially if
they maintain vital functions. If it is necessary to use the device near or together
with other devices, pay attention to how it is working.
- It is recommended reading carefully the entire operating manual before using
the device; keep carefully this operating manual.
- Checking the integrity of the device before each use is a fundamental
requirement to perform the treatment correctly. The device must not be used if the
buttons or cables are defective or malfunctioning.
-Do not use flammable materials while using the device.
It has to be kept out of the reach of children.
Warnings during the use
While using the Rf Beauty mini make sure to:
-remove your contact lenses if you are wearing them;
-always use conductive gel, do not use on dry skin;
-adjust the emission power in relation to the individual tolerance to the heat.
Side effects
-Redness
-Skin irritation
Contraindications
The use of the device is contraindicated:

10
Rev.10.15 - 22/10/2015
- in pacemaker wearers or other implantable electronic devices;
- do not treat the eyes zone;
- do not use in the presence of disturbances in the cardiovascular system, thyroid
and skin;
- do not treat pregnant women;
- do not use in the presence of skin cancer or glaucoma;
- do not use during hormonal drug therapies;
- do not use if you have had severe burns or hypertrophic scars.
Do not use the device on body parts which are not sensitive to the heat or on
patients suffering from one of the following diseases:
- hemorrhages;
- local or systemic infections;
- active dermatological pathologies;
- fever;
- coagulation alteration;
- acute inflammatory diseases.
If you had filler injections (e.g. Botox, hyaluronic acid and/or others), it is
recommended to use the device on those parts only after a period of 3-6 months.
MAINTENANCE AND CLEANING
Device and accessories
- In case of any real or alleged malfunctioning, neither tamper with the device nor
try to repair it by yourself.
Do not intervene on the device and do not open it. Only specialized and
authorized centers can repair the device.
- Avoid violent impacts that may cause damage and malfunctions to the device
even if undetectable immediately.
- Use this device in a dry environment and in an open space (not wrapped in any
material).
- Clean the device and accessories only with disinfectant or with quaternary
ammonium salt diluted with distilled water equal to 0.2-0.3%. Remove all the
residues of cream from the plate and the mobile electrodes carefully. After
cleaning/disinfecting the device, dry it and its accessories with a clean cloth.
- Always use the device and its accessories with clean hands.
- It is recommended that you use the device in a clean space in order to avoid the
contamination of the device and its accessories with dust and dirt.
- It is recommended using the device in a ventilated room, with a regular air
change.

11
Rev.10.15 - 22/10/2015
- It is recommended to clean/disinfect the electrodes after every use. Clean the
parts of the device which may come in contact with the patient after every use or
at least once per week.
- Place the device and its accessories in their original packaging when they are
not used or have to be transported.
Transportation
At the end of the treatment or during the transportation, place the device and its
accessories in the original carrying case.
Disposal
Do not throw the device or part of it in the fire, but dispose of the product in the
specialized centers and respecting the directives in force in your country. When
the product has to be disposed of, the user can give it back to the retailer when
purchasing a new device.
INSTRUCTIONS FOR USE
Switching on/off the device
-Plug the connector of the power supply unit in the intended slot.
-press for a few seconds the ON-OFF button. The display lights up and a beep
confirms that the device is on.
To turn off the device hold the ON-OFF button.
Pressing and holding the Mode (M) button you can select one of the three menus:
-program
-power level
-treatment duration
After selecting the menu, you can change the selection by quickly pressing the
Mode (M) button.
Therefore, in order to choose a program, you will need to press and hold the Mode
(M) button until SRT is selected, then by quickly pressing the same button you can
choose from the following programs:
SRT
05
Program
Power level
Treatment duration

12
Rev.10.15 - 22/10/2015
Program
Technology
SRT (skin rejuvenation and eye contour)
Radio frequency
WR (wrinkles reduction)
Radio frequency + red light
SR (rejuvenation)
Radio frequency + yellow light
In order to adjust the emission power it will be necessary to press and hold the M
button until the graph of the power level is selected.
By briefly pressing the same button you can set the desired energy level. We
recommend you start with level 1 and then possibly increase.
In order to adjust treatment duration it will be necessary to press and hold the M
button until this option is selected. By briefly pressing you can set a different time
(5, 10 or 15 minutes).
Once you have chosen the settings start the program by briefly pressing the ON-
OFF button. The emission indicator will start working and the LED light will turn on
(WR and SR programs).
To pause the device, briefly press the ON-OFF button.
Advice of use
A treatment on the entire face (including cheekbones, eye contour, forehead
and neck) may require between 15 and 25 minutes:
a. Remove makeup and wash your face and neck - 5 minutes
b. Dry your skin well and apply the gel for the treatment -1 minute
c. Perform the desired treatment for a total time between 5 and 15 minutes
d. Clean your skin and apply a moisturizer - 3 minutes
Important: apply a large amount of gel before performing the treatment and
reapply if necessary during the treatment. In order to avoid burns, never use
Globus RF Beauty Mini without the gel.

13
Rev.10.15 - 22/10/2015
How to perform the treatment step by step
Slowly slide the heads of Globus RF Beauty Mini on your skin. It is possible that you
feel a sensation of warmth in depth. The slower the movement of the heads on
your skin, the more heat will be felt. Make sure that both heads are always in close
contact with your skin throughout the treatment. During the duration of the whole
treatment continue to move the heads on your skin using circular movements on
your face.
1) Slide Globus RF Beauty Mini from the top of your clavicle to
the bottom of your jaw (avoid the thyroid)
2) Slide Globus RF Beauty Mini from your lower jaw to your
cheekbone.
3) Slide Globus RF Beauty Mini from the corner of your mouth
to your cheekbone.
4) Slide Globus RF Beauty Mini from your upper lip to your
cheekbone.
5) Slide Globus RF Beauty Mini from the corner of your nose to
the end of your cheekbone (avoid the temples).
(SR) Skin rejuvenation around eyes: 10 minutes. Important: for the area around
the eyes only use the SR program as it is the only one not emitting any light.
1) Slide Globus RF Beauty Mini from the inner corner of your
eye to the outside and then up to your eyebrow (avoid the
eyeball and the eyelid).
2) Slide Globus RF Beauty Mini from the outside of your eyelid
to your hairline without touching the eyebrow.
3) Slide Globus RF Beauty Mini up and down several times
between the eyebrow and the hairline.

14
Rev.10.15 - 22/10/2015
WARRANTY CONDITIONS
The device includes a 24-month warranty for the first user, starting from the
purchase date, which covers manufacturing flaws and defective materials, on
condition that the device is used properly and kept efficiently.
Warranty coverage is limited in the following cases:
- six (6) months for supplied accessories such as power supply units, etc.
- the warranty does not cover consumer accessories and materials such as gel,
etc.
The warranty is valid and enforceable in the country where the product was
purchased. In the event that the product is purchased in a EU country, the
warranty is valid in all the member states.
In order to take advantage from the warranty service, the user must comply with
the following warranty clauses:
1. the products returned for repairs have to be shipped in their original packages,
including their accessories, at customer's expenses.
2. The warranty is valid only when the receipt or invoice of the product, indicating
the purchase date of the product, is enclosed.
3. The repair work shall have no effect on the original warranty expiry date and
shall neither renew nor extend it.
4. If repairs detect no flaws, the costs of the intervention will be charged anyway.
5. The warranty becomes void if the flaw has been caused by: impacts, falls,
misuse of the product, use of non-original power supply units or chargers,
accidental events, alteration, replacement/detachment of the warranty seals
and/or mishandling. The warranty does not cover damages caused during
shipping when improper packages are used.
6. The warranty does not cover the inability to use the product, other incidental or
consequent costs or other expenses incurred by the purchaser.
The characteristics and dimensions reported in this manual are not binding. The
manufacturer reserves the right to modify the products without prior notice.

15
Rev.10.15 - 22/10/2015

16
Rev.10.15 - 22/10/2015
Table of contents
Other Globus Personal Care Product manuals
Popular Personal Care Product manuals by other brands

OxMed International
OxMed International P1NT10 Instructions for use

Vagaborn
Vagaborn 18242 quick start guide

Orliman
Orliman dyna-ort DAFOS OP11910 Use and maintenance instructions

Orliman
Orliman VALFEET 2SSD INSTRUCTIONS FOR USE AND PRESERVATION

Shani Darden
Shani Darden FACIAL SCULPTING WAND manual

GLO
GLO 910 Series Safety instructions