Glowworm Climapro2 RF User manual

Climapro2RF
Installation


0020094584_02 - 06/11 - Glow-worm - 3 -
INTRODUCTION
1 Instructions guidance
1.1 Product documentation
The instructions are an integral part of the
Climapro2RF and must be handed to the
user on completion of the installation in
order to comply with the current regulation.
• Carefully read the manual to enable
safe installation, use and servicing. No
liability can be accepted in the event
of damage for not complying with the
guidance in this instruction manual.
1.2 Associated documents
-User instructions
-User quick start guide
-Guarantee booklet with user precautions
-Installer manual
1.3 Explanation of symbols
eDANGER: Risk of electric shock.
ATTENTION: Risk of damage to
Climapro2RF or to its vicinity.
IMPORTANT: Useful information.
2 Climapro2RF description
2.1 Regulation and statutory
requirements
CE Mark
The CE mark indicates that the units
described in this manual are in compliance
with the following directives:
-European Directive Num. 2004-108 of
the European Parliament and the Council
regarding electromagnetic compatibility
-European Directive Num. 2006-95 of the
European Parliament and the Council
regarding low voltage
-Directive regarding telecommunications
equipment ( Directive R & TTE 99/5/
EEC of the Council of the European
Community)
3 Safety instructions and regulations
3.1 Safety instructions
All work inside Climapro2RF must be
carried out by a qualified professional or
the Glow-worm after-sales service.
Climapro2RF must only be installed by a
qualified professional who is responsible
for compliance with the standards and
regulations in force.
INTRODUCTION
EN

0020094584_02 - 06/11 - Glow-worm
- 4 -
Respect the basic safety instructions:
• Shut down the appliance.
• Disconnect the appliance from the power
supply.
• When work on the room thermostat is
completed, perform an operational test
and check for safety.
3.2 Regulations
During the installation and operation of the
room thermostat, the decrees, directives,
technical regulations, standards and
clauses hereafter must be complied with in
the versions that are currently in force.
4 Recycling
The recycling of the packaging
must be carried out by the
qualified professional who
installed the room thermostat.
4.1 Climapro2RF
Most of the appliance is made of recyclable
materials.
This symbol indicates that
this unit must not be disposed
of with household waste. It
should be selectively collected
for energy recovery, reuse or
recycling.
• Take the unit to an appropriate collection
point for processing, energy recovery
and recycling of waste.
By complying with this directive,
you will contribute to the
preservation of natural resources
and the protection of human
health.
4.2 Packaging
We recommend that you recycle the
packaging of Climapro2RF in a responsible
fashion.
• Sort the waste in order to separate
those elements which can be recycled
(cardboard, plastics) and those which
cannot be recycled.
• Dispose of the waste in accordance with
existing regulations.
INTRODUCTION
EN

0020094584_02 - 06/11 - Glow-worm - 5 -
INSTALLATION
5 Placement
5.1 Room thermostat
• Explain the following requirements to
the user of Climapro2RF.
Install the Climapro2RF:
-in a room protected from frost,
-on an interior wall of the reference room
in the home,
-at approximately 1.50 metres from the
floor (according to the regulations in
force).
Do not install Climapro2RF:
-near sources of heat, such as radiators,
chimney walls, televisions or solar
radiation,
-above a cooker that is likely to give off
steam and grease,
-on cold walls,
-between units or behind curtains
or other objects that might disturb
temperature recording for the ambient
air in the room,
-in a room that is heavily loaded with dust
or where the atmosphere is corrosive,
-near air currents that may come from
doors or windows.
5.2 Radio Receiver
Climapro2RF is suitable for
installation on Glow-worm
appliances with an external
ebus connection.
Not all appliances are able to
accept the RF receiver. In such
cases, the receiver can be fitted
to a wall.
Inside the appliance:
• Install the radio receiver in
corresponding location in the appliance
(see the appliance installation manual).
Outside the appliance:
• Install the radio receiver near the
appliance, approximately 1.8 m above
the ground.
• Keep the radio receiver away from
metallic parts (cables, circuit board,
metal surfaces) in order to avoid
interference.
5.3 Scope of delivery
This kit contains the following:
-Climapro2RF Programmable room
thermostat
-Wall support for the room thermostat
-Radio Receiver
-Packet containing 2 fixing screws with
rawlplugs
-4 “AA LR6 « alkaline batteries
-EBUS cable for radio receiver
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm
- 6 -
6 Fixing
6.1 Fixing the room thermostat
• Determine the installation location. See
the «Installation selection» chapter.
1
2
3
4
5
6
A
B
Key
1 Drilled holes
2 Screws
3 Attachment holes
4 Room thermostat support
5 Plugs
6 Room thermostat
• Position the room thermostat support (4)
on a wall.
• Drill (A) the screw holes (1) in
accordance with 2 mounting holes (3) in
the wall support (4).
• Insert the plugs (5) in the holes (1).
• Secure (B) the room thermostat support
(4) with screws (2).
• Slide the room thermostat (6) into its
support (4).
6.2 Installing the radio receiver
The receiver should be installed
outside the appliance if the
appliance control box does not
have a location for the radio
receiver.
Case n°1 - radio receiver on control box unit
24
V
230
V
1
2
Key
1 Appliance control box
2 Radio receiver
• Locate the radio receiver installation
point in the appliance.
• Slide the radio receiver into the notches.
1
2
Key
1 Radio receiver
2 Location of radio receiver
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm - 7 -
Case n°2 - radio receiver in the appliance
control box
1
2
B
A
Key
1 Electrical unit
2 Radio receiver
Case n°3 - radio receiver outside appliance
• Determine the installation location.
• See the «Installation selection» chapter.
Check correct operation before
permanently installing the
receiver.
B
A
5
4
2
1
3
Key
1 Radio receiver
2 Attachment screws
3 Attachment holes
4 Plugs
5 Holes
• Position the radio receiver (1) on a wall.
• Drill (A) the screw holes (5) according to
the unit’s attachment hole (3) or use the
sticky pad if provided.
• Insert the plug (4) in the hole (5).
• Attach (B) the radio receiver with the
attachment screw (2).
• Respect the current electrical installation
standards when connecting the EBUS
cable between the radio receiver and the
appliance.
7 Electrical connections
The electrical connection of
the room thermostat must
be carried out by a qualified
professional.
The radio receiver must
be connected via an EBUS
connector.
7.1 Main board
123
Key
1 Connecter
2 Electrical wires
3 Insulation
When you connect electrical wires on a
connector on the electronic board:
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm
- 8 -
• Keep a distance of 30 mm maximum
between the connector (1) and the
insulation (3).
7.2 Connecting the radio receiver
The location of the EBUS
terminal block varies according
to the heating system. It is
always identified by having
«BUS» written on it.
• Use the EBUS connection cable
provided.
• Cut the EBUS connection cable to the
length necessary for your installation.
Case n°1 - radio receiver on control box
• Connect the EBUS cable, following the
order of operations from (A) to (F).
230
V
24
V
C
B
A
2
1
3
Key
1 Access for 24 V connection
2 Control box unit
3 Pre-cut part of control box unit
• Open (A) the access for the 24 V
connection (1).
• Cut (B) the pre-cut part (3) of the control
box unit (2).
• Remove (C) the pre-cut part of the
control box unit (2).
230
V
RT 24V T° extBUS
BUS
24 V
6
5
4
3
2
1
DE
F
Key
1 EBUS connection cable
2 Link for the connection terminal block on
the room thermostat
3 EBUS terminal block for the main board
4 Control box unit
5 Connector for the radio receiver
6 Pre-cut part of control box unit
• Do not remove the link from the terminal
block (2) for connecting the main board’s
room thermostat.
• Pass (D) the EBUS cable (1) through the
cable passage created by removing the
pre-cut part (6).
• Connect (E and F) the EBUS cable (1) to
the radio receiver’s connector (5) and
to the EBUS terminal block on the main
board (3).
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm - 9 -
Case n°2 - radio receiver in the control box
RT 24V T° extBUS
BUS
24 V
B
A
5
4
3
2
1
Key
1 EBUS connection cable
2 Link for the connection terminal block on
the room thermostat
3 EBUS terminal block for the main board
4 Control box unit
5 Connector for the radio receiver
• Do not remove the link from the terminal
block (2) for connecting the main board’s
room thermostat.
• Connect (A and B) the EBUS cable (1)
to the radio receiver connector (5)
and the EBUS terminal on the heating
system’s motherboard (3). Polarity is not
important.
Case n°3 - radio receiver outside the
appliance
1
2
3
Key
1 Ebus and 0V connection
2 Cable strain relief
3 Connector for the radio receiver
• Do not remove the link from the terminal
block for connecting the main board’s
room thermostat.
• Connect the EBUS cable to the radio
receiver connector and the EBUS and 0V
connection in the electrical cartridge.
Polarity is not important.
8 Commissioning
8.1 Appliances included in the
installation
Switch on the appliances that make up the
installation (see the installation manuals).
8.2 Room thermostat
• Remove the insulating strip located in
the battery compartment.
8.3 Pairing (detection)
8.3.1 The room thermostat delivered
with a radio receiver
The pairing between the room thermostat
and its radio receiver requires no action on
your part. This is done at the factory.
8.3.2 The radio receiver with wireless
outdoor sensor
The radio receiver can be paired with the
wireless outdoor sensor (see the outdoor
sensor installation manual).
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm
- 10 -
9 Access to the installer menu
• Press button
for 7 seconds.
• Enter the installer access code 96.
10 Description of the installer menu
Menu Browsing
Use the buttons:
Select with the button:
Press the button:
- to return to the
professional menu screen,
- for 3 seconds to
return to the user's main
screen.
10.1 Functions
Showing, enabling and
disabling of functions is
reflected in the user menu.
10.1.1 Heating function
Menu This menu allows you to:
Set the maximum adjustable
room temperature
Correct the measurement of
the room temperature.
To enable or disable the
modulating setting for the
heating flow temperature*.
(*) automatic adjustment of the heating flow
temperature
10.1.2 Hot water function
Menu This menu allows you to:
Show or hide the domestic
hot water function in the end
user menu.
To set the maximum hot
water temperature.
Enable or disable the domestic
hot water heating program.
10.1.3 Cooling function
Menu This menu allows you to:
Show or hide the cooling
function in the end user
menu.
Enable or disable the cooling
program.
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm - 11 -
10.2 Settings
Menu This menu allows you to:
To set the outdoor sensor:
-adjustment of the
measured outside
temperature,
-selection of heating curve
(consult the outdoor
sensor installation
manual).
Adjust the date and time
Choose the language
Indicate the phone number
that will appear in the After-
sales Service messages.
Display information: zone,
type and version of software
for Climapro2RF.
10.3 Radio
Menu This menu allows you to:
Connection between radio
receiver and the thermostat.
Test the quality of the radio
signal (thermostat and
wireless outdoor sensor).
• To exit the installer menu press button
for 3 seconds or until the main
screen is displayed.
11 Control / Commissioning
Once the appliance is installed, check the
operation:
• Switch on the appliance according to the
indications of the operating instructions
and check the operation.
• Check the whole control and safety
devices, their setting and their operating
state.
12 User information
At the end of the installation:
-explain the operation of the appliance
and its safety devices to the user, if
necessary provide a demonstration and
answer any questions;
-give the user all the required
documentation,
-fill in the documents where necessary;
-advise the user of the precautions
necessary to prevent damage to the
system, appliance and the building;
-remind the user to service the appliance
annually.
INSTALLATION
EN

0020094584_02 - 06/11 - Glow-worm
- 12 -
MAINTENANCE
13 Fault diagnosis
In case of loss of signal between
the room thermostat and radio
receiver (eg. : low battery), the
heating system uses its own
function settings.
Faults described in this
chapter should be carried out
by a qualified engineer and
if needed by the After Sales
Service.
You will find a list of certain error in the
user manual.
4
1
2
3
5
Legend
1 Radio receiver
2 Radio receiver cover
3 Red LED
4 Radio receiver circuit board
5 Green LED
In the event of a problem:
• Check the error messages in the
Climapro2RF display zone on the main
screen.
• Remove the receiver radio (1) cover (2) in
order to check the 2 LED.
• Check the status of the 2 LED (green (5)
and red (3) red) installed in the radio
receiver’s circuit board (4).
MAINTENANCE
EN

0020094584_02 - 06/11 - Glow-worm - 13 -
Radio
receiver
Cause Solution
Green LED
off
Red LED off
- Failure of electrical current
- Defective EBUS connection
cable
• Ensure that there is no interruption to the electricity
network and that the appliance is properly connected
and turned on.
• Check the electrical connection between the radio
receiver and the appliance.
Red LED lit - Generator failure
- Radio signal transmission
failure
- EBUS communication failure
- Defective radio receiver or
transmitter
- Defective EBUS connection
cable
• Check that:
- the generator operating status is correct.
- the room thermostat’s batteries are correctly
installed in their compartment..
- the battery polarity is not reversed.
- the batteries are not dead. If so, replace them with
new batteries.
• Check the electrical connection between the radio
receiver and the appliance.
• Check the radio communication between the
thermostat and the receiver.
MAINTENANCE
EN

0020094584_02 - 06/11 - Glow-worm
- 14 -
TECHNICAL DATA
14 Climapro2RF
Description Unit Climapro2 RF
Average range in open air (*) m 100
Average range within the home (*) m 25
(*) Depends on the installation’s conditions and the electromagnetic environment.
Room thermostat
Maximum room temperature. Room temperature authorized in
the room where the room thermostat is installed
°C 50
Max. of hot water allowed °C 65
15 Radio receiver
Description Unit Climapro2 RF
Average range in open air (*) m 100
Average range within the home (*) m 25
(*) Depends on the installation’s conditions and the electromagnetic environment.
Radio receiver
EBUS power supply V 24V
Electrical connection cable section mm² 2 x 0.75
Max. length of electric connection cables m 300
TECHNICAL DATA
EN


*2702188_rev2*
0020094584_02 - 06/11 Subject to engineering changes
GLOW-WORM
Nottingham Road,
Belper, Derbyshire.
DE56 1JT
www.glow-worm.co.uk
Because of our constant endeavour for
improvement, details may vary slightly
from those shown in these instructions.
Other manuals for Climapro2 RF
2
Table of contents