Instructions for Use
Notes and General Information
Theseinstructionsshouldbereadandcarefullyfollowedforthe
safe and economical use of your appliance.
These gas fire fronts are to be used with specially designed
Glow-worm 45/4 & 54/4 Back Boiler Units only.
The fire front and back boiler must be installed as a complete
unit.
The boiler and fire can be operated together or independently.
Important Notice
This appliance is for use on natural gas (G20) as distributed in
the United Kingdom and Ireland and must not be used on any
other gas.
Aslightsmell mayoccurfor ashorttime afterinitiallighting, this
is quite normal and with use it will quickly disappear.
Combustible furniture or materials must not be placed closer
than 1m (39in) in front of the fire front.
Soft wall coverings (e.g. embossed vinyl, etc.) which have a
raisedpattern,areeasilyaffectedbyheat. Theymay, therefore,
scorchorbecomediscolouredwhenclosetoaheatingappliance.
Please bear this in mind whenever you are considering
redecorating
The convection air openings at the top of the fire front and air
inlet grilles at the sides and base must never be restricted.
Never use the fire with a damaged fuelbed.
The Gas Safety (Installation and Use)
Regulations
In your interests and that of safety it is the Law that ALL gas
appliances are installed by a competent person in accordance
with the current issue of the above regulations.
Maintenance
To ensure the continued efficient and safe operation of the
appliance it is recommended that it is checked and serviced as
necessary at regular intervals. The frequency of servicing will
dependupontheparticularinstallationandusage,butingeneral
once a year should be enough.
If this appliance is installed in a rented property there is a duty
of care imposed on the owner of the property by the current
issue of the Gas Safety (Installation and Use) Regulations,
Section 35.
It is the law that servicing must be carried out by a competent
person.
Pleasebeadvisedthat the‘Benchmark’logbook(supplied with
the Back Boiler Unit) should be completed by the installation
engineer on completion of commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boilerLogbook. YoucancheckyourinstallerisCORGIregistered
by calling CORGI direct on :- 01256 372300.
Servicing
In the United Kingdom servicing can be carried out either by a
Heatcall Service engineer or a CORGI registered installer.
If you require your appliance to be serviced, please contact
Heatcall on (01773) 828100 and quote the following details;
Model name and Serial numbers.
Fire front-positioned bottom right inside of the case.
BackBoiler-positionedonthebaseoftheboilernexttothe
control box
If you wish to replace the fuelbed and do not know where they
can be obtained please contact Hepworth Heating on (01773)
824141 or your nearest stockist.
In the United Kingdom, for general advice about gas and your
gas fire contact Hepworth Heating Ltd.
Electrical Supply
WARNING. The appliance must be earthed.
Connection of the appliance and any system controls to the
mains (230V-50Hz) must be through a 3A fused double pole
isolating switch, having a minimum double pole contact
separationof3mm,servingonlytheboilerandsystemcontrols.
The colours of three core flexible cable are, Brown - live, Blue
- neutral, Green and Yellow - earth.
Frost
If the boiler is to be out of use for any long time during severe
weatherconditionswerecommendthatthewholeofthesystem,
includingtheboilerbedrainedofftoavoidtheriskoffreezingup.
If fitted, switch off the immersion heater in the domestic hot
water cylinder.
Ifyouare inanydoubtyourinstallationorservicing companyor
the local gas undertaking should be contacted.
Clearance
A shelf or surround of a maximum depth of 150mm may be
fitted,providedthatclearancesaboveandatthesidesofthefire
frontareas shownindiagram1. Forashelf madefromwoodor
other combustible materials deeper than 150mm add 12.5mm
for every 25mm of shelf depth over 150mm.
On no account must a carpet or other combustible material be
laid directly under the fire, unless the minimum clearances
shown in diagram 1, is achieved.
The dimension is taken from the bottom of the fire case to the
top of the carpet pile or other floor covering.
Hearth
A fire proof hearth under the fire front must have the minimum
dimensions as shown in diagram 2.
IFYOU SMELL GAS
DON'T SMOKE.
EXTINGUISH ALL NAKED FLAMES.
DON'T TURN ELECTRICAL SWITCHES
ON OR OFF.
TURN OFF THE GAS SUPPLY AT THE METER.
OPEN DOORS AND WINDOWS TO GET
RID OF THE GAS.
IMMEDIATELY CALL THE GAS EMERGENCY
SERVICE.
Advice/help should be obtained from your installation/
servicing company or the local gas undertaking.