Instructions for Use
ThisfirefrontmaybefittedtoaGlow-wormbackboilerWITHOUT
aflueblockagesafetydevice. Pleaserefertothesupplementary
instructions at the end of the Instructions for Use, especially
“Lighting the Boiler”.
Theinstructions consist of two parts, Installation and Servicing
Instructions for the Back Boiler Unit, Use, Installation and
Servicing Instructions for the Fire Front, which includes the
GuaranteeRegistrationCard.Theinstructions formanintegral
partofthe applianceandmust,tocomply withthecurrentissue
oftheGasSafety(InstallationandUse)Regulations,behanded
to the user on completion of the installation.
The Gas Safety (Installation and Use)
Regulations
In your interests and that of safety it is the Law that ALL gas
appliances are installed by a competent person in accordance
with the current issue of the above regulations.
General
These notes should be read and carefully followed for the safe
and economical use of your back boiler and fire front.
Important Notice
This appliance is for use only on G20 gas.
ThisGlow-wormfirefrontistobeusedwithaspeciallydesigned
Glow-worm Back Boiler Unit only.
The fire front and back boiler must be fitted as a
complete appliance.
Thisisacombinedcentralheatingbackboilerandgasfirefront.
Thebackboilerandfirefrontcanbeoperatedeithertogetheror
independently.
Intheeventofapowerorignitionsystemfailurethefirefrontcan
stillbe used on its own, instructions on how to do this are given
under “Lighting the Fire Front with a Match or Spill”.
Aslightsmellmayoccur,forashorttime,afterinitiallighting,this
is quite normal and will quickly disappear.
With a little use the interior of the fire front will discolour and
acquire the appearance of a solid fuel fire.
Combustiblefurnituremustnotbeplacedcloserthan1metrein
front of the fire front.
Clothingorotherflammablematerialsmustnotbeplacedonthe
fire front casing.
The convection air openings at the top of the fire front and air
inlet grilles at the sides and base must never be obstructed.
Important. Soft wall coverings, for example, blown vinyl
wallpaper, are easily affected by heat, they may therefore,
scorchorbecomediscolouredwhenclosetoaheatingappliance.
This should be borne in mind when having a heating appliance
fitted and when redecorating.
The glass panel on this fire front conforms to the requirements
of the current issue of BS1945 and satisfies the Heating
Appliance (Fireguard) Regulations.
Thefirefrontmustnotbeusedifthispanelisbrokenormissing.
WARNING. Theglasspanelgetsveryhotwhenthefirefrontis
on and MUST NOT be touched.
The glass panel does not provide full protection for the young,
elderlyorinfirm. Insuchcasesextra security mustbeprovided
by fitting a fireguard which complies with the current issue of
BS6539 “Fireguards for use with solid fuel appliances” or the
current issue of BS6778 “Fireguards for use with portable, free
standing or wall mounted heating appliances”.
Maintenance
To ensure the continued efficient and safe operation of the
appliance it is recommended that it is checked and serviced at
regular intervals. The frequency of servicing will depend upon
theparticularinstallation and usage, but ingeneralonce a year
should be enough.
If this appliance is installed in rented property there is a duty of
care imposed on the owner of the property by the current issue
of the Gas Safety (Installation and Use) Regulations, Section
35.
ItistheLawthatservicingiscarriedoutbyacompetentperson.
To obtain service, please call your installer or Heatcall (Glow-
worm’s own service organisation) using the telephone number
given on the fire plinth.
Please be advised that the ‘Benchmark’ logbook should be
completed by the installation engineer on completion of
commissioning and servicing.
All CORGI Registered Installers carry a CORGI ID card, and
have a registration number. Both should be recorded in your
boilerLogbook. YoucancheckyourinstallerisCORGIregistered
by calling CORGI direct on :- 01256 372300.
Heat Input - Fire Front
This gas fire front will run for about 4.4hrs at full on rate on one
therm of gas. The price of a therm of gas will vary according to
the tariff in your area.
At tap position 1 - centre section flame effect
At tap position 2 - centre section flame effect with
outer section fuel bed glow
At tap position 3 - centre and outer sections flame
effect with fuel bed glow
At tap position 4 - (full on) full flame effect and fuel
bed glow
Gas Leak or Fault
If a gas leak or fault exists or is suspected the appliance must
be turned off, including the electrical supply and must not be
used until the fault has been put right. Advice/help should be
obtained from your installation/servicing company or the local
gas undertaking.
Clearances
A shelf or surround of a maximum depth of 150mm may be
fitted,providedclearancesareasdiagram1,however,forevery
extra 25mm above the fire front the depth of the shelf may be
increased by 25mm.
Onnoaccountmaycarpetorothercombustiblematerialbelaid
directly under the fire front, unless the minimum clearances
shown in diagram 2 is achieved.
The dimension is taken from the bottom of the fire front casting
to the top of the carpet pile or other floor covering.