GMI MEGA DETECTION PHOENIX User manual

www.Megalocators.com
Geophysical Measuring Instruments
•Visual exploration of all Deep buried treasures
•All in one device to meet the needs of
all treasure hunters
Complete Set of Detection Tools for
Professional Treasure Hunters
SEARCH SYSTEMS
· Most Powerful 3D Ground Scanner
· Complete Solution for Professional Treasure Hunters
· Unearth All Buried Deep Treasures Visually
· New Detection Technologies: M.G.S, V.S.T
· 3D & 2D Result Visualization on Screen or Tablet
· Multi Visual Analyzer app for Android Tablets
· Multilingual Easy to Use Software Program

USER MANUAL

CONTENTS
List of contents
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Property rights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly (V.S.T) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly (Ground Scan) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Assembly (Stack Holder). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Panel Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ground Scan System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scan Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Live Stream System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pin Pointer System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Multi Visual Analyzer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Costumer Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
3
4
5
6
8
9
10
11
14
15
21
26
29
32
34
39
40
2

WARNINGS
Do not assemble and operate the device before reading the user manual.
3
The device may only be dismantled or repaired by MEGA DETECTION Gmbh or its authorized
service centers. Unauthorized disassociation / infiltration of the internal components of the main
monitor or other units for any reason cancels the warranty.
Do not store the device and its components under extremely low or high temperatures for long
periods (the preferred storage temperature is -20 ° C to 60 ° C / -4 ° F to 140 ° F).
Do not use the device indoors. The device may constantly give target signals indoors as there
are many metals. Use the device outdoors, in open fields.
Do not submerge the device or its accessories in water. Do not expose the equipment to excessively
moist environments.
Do not leave another detector or electromagnetic device close to the device (within a distance of
less than 10 meters by 30 feet)
Protect the main unit of the device from impacts during normal use. For transportation, place the
detector carefully in the original carton and secure with shock-resistant packaging.
Keep the device out of your shoes while walking. The device may detect minerals on you or inside
your shoes as targets.

PROPERTY RIGHTS
Copyright © Mega Detection (© 2021 All Rights Reserved)
4
No part of this guide may be reproduced, including the products and programs described in it.
Any use of material, reproduction, storage or translation of this information without prior permis-
sion from MEGA DETECTION Gmbh is subject to legal liability of its owner.
MEGA DETECTION invites all users to ensure that the acquisition and use of this type of equipment
complies with the laws and regulations of the countries in use and is not responsible for the legal
consequences if the laws state otherwise.
MEGA DETECTION does not bear in all cases or any of its directors, officials, employees, and
authorized agents indirect, special, incidental, or consequential damages (including damages for
interest loss, business loss, loss of use or data, business interruption and the like), even if the
company was notified of the possibility of such damages arising from any defect or error in this
manual or product.
The specifications and information contained in this guide are published for information use only
and are subject to update periodically at any time without notice to the user.
The products and company names that appear in this guide may be registered trademarks and
copyrights are reserved for the related companies and mentioning them here is used only for
identification and for the benefit of the owner, without intentionally infringing on the property
rights of these companies.
MEGA DETECTION is not responsible for misunderstanding this manual or misusing the device in
violation of the instructions in this guide.

INTRODUCTION
Ground Scan System
Live Stream System
Pin Pointer System
5
It is the latest release of Mega Detection. The comprehensive imaging ground scanner and it is the first
device in the world to include all imaging scanning technologies in one device, through three different
search systems.
The Phoenix device includes a completely new technology to scan the ground via the MGS multi-ground
scanner and the VST high-signal transmitter and receiver probe, which provide professional surveying
tools to scan the ground to large depths accurately and quickly with visual representation of the scanning
results on the device screen or via the Multi Visual Analyzer‘s application on the tablet.
The Phoenix device, via scanning tools and built-in search systems, is a versatile device with which it can
search for gold treasures and burials at great depths, excavate antiquities, detect all kinds of minerals,
as well as detect voids, tunnels and caves.
Thank you for choosing the Phoenix product from Mega Detection. For more information, you can
visit our website.

PACKAGE CONTENT
1
2
4
A B
C
D
E
F
3
5
6
7
11
12
9
10
6
8

Main unit
V.S.T Sensor
Lithium-Ion Battery
Conector Base
Higher Stick (Shaft)
Medium Stick (Shaft)
Lower Stick (Shaft)
M.G.S 60 Scanner
Long-Range Antennas ( x2 )
Headphones
Armrest (Holder)
Accesories Box including:
A. M.G.S Screw and Nut (x2)
B. Washer for Plastic Stick (Shaft)
C. Armrest (Holder) Screws (Spare Parts)
D. Universal Power Adapter
E. Headphones Cable
F. Battery Charger (220V)
1
2
3
4
5
6
7
8
9
10
11
12
PACKAGE CONTENT
7

LIVE STREAM SYSTEM
PIN POINTER SYSTEM
OVERVIEW
8
GROUND SCAN SYSTEM

ASSEMBLY
1Connect V.S.T Sensor to the device as it shown in the picture
2Use the power jack to connect the battery
Live Stream System
Pin Pointer System
9
Power Jack

ASSEMBLY
1
2
3
4
6
5
1Attach the medium pipe inside the higher pipe.
2Assemble the scanner and the lower pipe using the specific screw and nut.
3Attach the battery to the hand holder so that the battery clip is in its specific place
4Connect the scanner cable into the connector base
5Put the device on the holder as it shown in next page
6Connect the battery to the device
Ground Scan System
10

ASSEMBLY
1
2
3
Attach the main unit on the holder
1Prepare the main unit and the stack unit
2Fit the main unit and the holder rail as
Parallel position
3Put the main unit into the rail until you hear
a sound come from the lock pin
11

ASSEMBLY
1
2
De attach the main unit from the holder
Lock pin
1Press the Lock pin on the holder
2Pull the main unit to front side
12

ASSEMBLY
1
1
2
Unscrew the screw on the holder counter clockwise
2fit the main unit as the prefared degree and Close the screw again
13
To fit the view degree of main unit on the holder, there is an option users can
use. This option helps to fit device position on holder that users can see the
display screen as well as possible.

PANEL KEYS
1. Power Key
3. OK Key
2. Back Key (Backward)
4. Home Key
5. Control Settings Arrow Keys (Right - Left - Up - Down)
OK
OK
5
4
3
2
1
14

SETTINGS
Power ON
Power OFF
Adjust Settings
You can choose other options in the screen using arrows
Go on setting icon and press
OK
15
You can set the device setting by selecting
Settings from the main menu
To turn off the main unit, just press the power
key , when confirmation message
appears, choose "Yes" to confirm, or "No" to
cancel. after power off the device press two
time on battery power button to power off the
battery.
To power on the main unit, connect the battery to the main unit then power on the battery by pressing
one time on battey power button, then press on on the main unit.

1. Use the left/right arrows
To select “date & time” item then press
SETTINGS
Date
3. In this window use arrows to select the
Correct date then after setting each one
Press to save
2. Use top/ down arrows to select
“Set Date” then press
OK
OK
OK
16
4. After adjusting the setting press back
on device controls key
Use this option to save power when using the
device.
With this option, the battery life can be
increased by at least 50% , it depends on the
search system and the type of connected
probe

To activate the device's security settings, you
must click on the security lock option
within the security settings.
SETTINGS
Time
2. In this window use arrows to select the
correct time then after setting each one
press to save
1. While you are in date and time setting
menu use top/ down arrows to select
“Set Time” then press
OK
OK
17
After adjusting the setting press back
on device controls key
After activating the previous option, the securi-
ty lock code can be set by the "Set Security
Code" option.
When operating the device for the first time,
the device will ask you to enter the security
code (device password), which you get from
the manufacturer or through the authorized
distributor of the device in your country.
The security lock option can be locked in the
device so that the device does not require the
entry of the code after each operation

SETTINGS
You can use this menu to reset the device
Settings.
There is three type of resets
1. Reset settings:
By using this option all settings in
The device will back to the default
Settings, but the you will keep the
Information saved in the memory
2. Factory Settings
With this option, all settings in the
device will revert to the factory
defaults and the memory data will
be erased
2. Clear Memory
By using this option the memory
Data will be erased
you can control screen settings using this
menu.
Sleep Mode:
By turning on this option, the
device's screen will go to sleep in
the absence of any activity.
Brightness
user can control screen brightness
using this option.
18
After selecting the reset option, a confirmation
window will appear. By clicking "Yes" in this
window, the reset will be done.

SETTINGS
19
The device software interface is available in
12 languages, namely:
1. English 2. German 3. Spanish
4. French 5. Italian 6. Russian
7. Turkish 8. Chinese 9. Hebrew
10. Urdu 11. Arabic 12. Persian
User can control the device's sound status
using this menu.
General Volume Level:
Use this option to control the sound of the
whole device.
Keypad Volume:
Use this option to control the keypad sound
volume
Scan Volume:
Use Up/Down arows to select the sound
settıng you need to change and then press on
OK then use Left/Right arows to change the
sound volume
To change the language, the user has to go to
the language tab, then choose "Change
Language" using the Up / Down arrow keys,
then press OK, then choose the preferred
language using the Left / Right arrow keys,
then press OK
This manual suits for next models
1
Table of contents