NETIChome®
Double On/Off
Ordering code: NEWHAB1 Type: Double On/Off
Double On/Off module is part of NETIChome®system.
This module is used for switching On or Off two electrical devices (e.g.
lights, fans, etc ...). The module can be controlled either through wireless
network or through the wall switches.
The module is designed to be mounted inside a “flush mounting box”
and is hidden behind a traditional wall switch.
Module measures power consumption of two electrical devices and
supports connection of digital temperature sensor.
Supported switches
Module supports mono-stable switches (push button) and bi-stable
switches. The module is factory set to operate with bi-stable
switches.
Installation
Before the installation disconnect power supply.
Connect the module according to electrical diagram.
Locate the antenna far from metal elements (as far as possible).
Do not shorten the antenna.
Danger of electrocution!
Module installation requires a great degree of skill and may be
performed only by a qualified and licensed electrician.
Even when the module is turned off, voltage may be present on its
terminals. Any works on configuration changes related to
connectcon mode or load must be always performed by
disconnected power supply (disable the fuse).
Note
Do not connect the module to loads exceeding recommended values.
Connect the module only in accordance to the below diagrams. Improper
connections may be dangerous.
Package contens
Double On/Off
Electrical diagram 230VAC
Notes for the diagram:
Electrical diagram 24VDC
Notes for the diagram:
Durability of the device depends on applied load. For resistive load
(light bulbs, etc.) and 4A current consumption of each individual
electrical device, the durability exceeds 70 000 switches of each
individual electrical device.
Module Inclusion (Adding to wireless network)
Connect module to power supply,
bring module within maximum 1 meter (3 feet) of the NETIC,
enable add/remove mode on NETIC,
auto-inclusion (30 minutes after connected to power supply) or
press service button Sfor more than 1 second or
press push button I1 three times within 3s (3 times change
switch state within 3 seconds)
Module Exclusion/Reset (Removing from wireless
network)
Connect module to power supply
bring module within maximum 1 meter (3 feet) of the NETIC,
enable add/remove mode on NETIC,
press service button Sfor more than 5 second or
press push button I1 five times within 3s (5 times change
switch state within 3 seconds).
By this function all parameters of the module are set to default values
and own ID is deleted
Association
Association enables Double On/Off module to transfer commands inside
wireless network directly (without NETIC) to other NETIChome modules.
Associated Groups:
Group 1: basic on/off (triggered at change of the output Q1 state and
reflecting its state)
Group 2: basic on/off (triggered at change of the output Q1 state and
reflecting its state)
Group 3: default reporting group (reserved for the NETIC)
Configuration parameters
Parameter no. 1 –Input 1 switch type
Available configuration parameters:
default value 1
0 mono-stable switch type (push button)
1 bi-stable switch type
Parameter no. 2 –Input 2 contact type
Available configuration parameters:
default value 1
0 mono-stable switch type (push button)
1 bi-stable switch type
Parameter no. 10 - Activate / deactivate functions ALL ON/ALL OFF
Available configuration parameters:
default value 255
255 - ALL ON active, ALL OFF active.
0 - ALL ON is not active ALL OFF is not active
1 - ALL ON is not active ALL OFF active
2 - ALL ON active ALL OFF is not active
On/Off module responds to commands ALL ON / ALL OFF that may be
sent by the NETIC or by other controller belonging to the system.
Parameter no. 11 - Automatic turning Off relay Q1 after set time
Available configuration parameters:
Default value 0
0 - Auto OFF disabled
1- 65535 = 10mseconds –655,35 seconds Auto OFF enabled, with
define time, step is 10mseconds
Parameter no. 12 - Automatic turning Off relay Q2 after set time
Available configuration parameters:
Default value 0
0 - Auto OFF disabled
1- 65535 = 10mseconds –655,35 seconds Auto OFF enabled, with
define time, step is 10mseconds
Parameter no. 30 - Saving the state of the relays Q1 and Q2 after a
power failure
Available configuration parameters:
default value 0
0 –Double On/Off module saves its state before power failure
(it returns to the last position saved before a power failure)
1 - Double On/Off module does not save the state after a
power failure, it returns to "off" position.
Parameter no. 40 –Power reporting in Watts on power change for
Q1
Set value means percentage, set value from 0 –100 = 0% - 100%
Available configuration parameters:
default value 5
0 –Reporting Disabled
1 –100 = 1% - 100% Reporting enabled. Power report is send
(push) only when actual power in Watts in real time change for
more than set percentage comparing to previous actual power in
Watts, step is 1%.
NOTE: if power changed is less than 1W, the report is not send (pushed),
independent of percentage set.
Parameter no. 41 –Power reporting in Watts on power change for
Q2
Set value means percentage, set value from 0 –100 = 0% - 100%
Available configuration parameters:
default value 5
0 –Reporting Disabled
1 –100 = 1% - 100% Reporting enabled. Power report is send
Output for electrical device no. 1
Output for electrical device no. 2
Input for switch to control electrical device no. 2
Input for switch to control electrical device no. 1
Terminal for digital temperature sensor (only for
NETIChome compatible digital temperature sensor,
which must be ordered separately).
Output for electrical device no. 1
Output for electrical device no. 2
Input for switch to control electrical device no. 2
Input for switch to control electrical device no. 1
Terminal for digital temperature sensor (only for
NETIChome compatible digital temperature
sensor, which must be ordered separately).
Service button (used to add or remove
module from the NETIChome system).