METRA HIT 1A and METRA HIT 2A
Analog Multimeters
2GOSSEN METRAWATT GMBH
METRA HIT 2A: Current Measuring Ranges
Resistance Measuring Ranges
2) At a battery voltage of 1.5 V
Capacitance Measuring Ranges
3) Rough measurements in the resistance measuring ranges, determination
of measured values with comparative scale
Reference Conditions
Ambient temperature
+23°C ±2K
Normal position
of use Horizontal
Frequency 40 ... 60 Hz
Line Voltage For : sinusoidal
Relative humidity 40 ... 60%
The instrument is equipped with half-wave rectification and is
RMS calibrated. It evaluates the arithmetic mean value of a
half-wave and displays different values for pulsating voltage and
current depending upon polarity.
Other influencing quantities: per IEC/EN 60 051
Ambient Conditions
Storage temp. range -25 to 65° C (without battery)
Relative humidity
Up to 75%, no condensation allowed
METRA HIT 2A: Accuracy (under reference conditions per IEC/EN 60 051)
Class 2.5 for and , max. additional intrinsic error in the 15 A :
range: ±2%; in the 1.5 V~ range: +1/–2,5%,
class 2.5 for Ω(error relative to 52 mm scale length)
METRA HIT 2A: A
dditional accuracy class influence and Nominal Ranges of Use
Ambient temp. For : 0 ... +23 ... +40° C
For : +13 ... +23 ... +35° C
Frequency 1.5 ... 500 V ranges:
35 ... 40 ... 60 ... 1000 Hz
1.5 mA ... 1.5 A ranges:
35 ... 40 ... 60 ... 1000 Hz
15 A range:
40 ... 45 ... 60 ... 1000 Hz
Other influencing quantities: per IEC/EN 60 051
Power Supply
Battery for resistance
measurement One 1.5 V mignon cell per IEC LR6/R6
(size AA), leak-proof
Electrical Safety
Safety class II per IEC/EN 61010-1:2001/
VDE 0411-1:2002
Measuring category II
Nominal voltage 500 V
Test voltage 3.5 kV~
Fouling factor 2
Fuse links Replaceable
METRA HIT 1A:
F1: FF630mA/700V AC (50 kA), 6.3 x 32
F2: FF6.3A/500V AC (50 kA), 6.3 x 32
METRA HIT 2A:
F1: FF1.6A/700V AC (50 kA), 6.3 x 32
F2: FF16A/500V AC (50 kA), 6.3 x 32
Soldered permanently into place
750 mA / 600 V AC
METRA HIT 1A: Overload Capacity
METRA HIT 2A: Overload Capacity
1) Fuse F1 blows in the event of overloading.
2) Ranges are protected against overloading with PTC resistor
3) Max. 1 minute
Current Voltage Drop, Approx.
50 µA 0.158 V —
1.5 mA 1.16 V 1.21 V
15 mA 1.25 V 1.25 V
150 mA 1.25 V 1.25 V
1.5 A 1.95 V 1.95 V
15 A 0.43 V 0.49 V
Resistance Scale Span Value at Scale
Middle (Ri)
Max. Measuring
Current Imax 2),
Approx.
Ωx 1 1 Ω ... 1 kΩ18.00 Ω83 mA
Ωx 10 10 Ω... 10 kΩ180.00 Ω8.3 mA
Ωx 100 100Ω... 100 kΩ1.8 0 kΩ0.83 mA
Ωx 1000 1kΩ... 1 MΩ18.00 kΩ0.083 mA
Capacitance 3) Scale Span
µF x 1000 2000 ... 200 000 µF
µF x 100 200 ... 20000 µF
µF x 10 20 ... 2000 µF
µF x 1 2 ... 200 µF
Range To Range To
0.15 V –
0.5 V –
1.5 V –
5.0 V –
15.0 V –
50.0 V –
150.0 V –
500.0 V –
20 V 1)
50 V 2)
100 V 2)
150 V 2)
250 V 2)
250 V 2)
300 V 2)
500 V 2)
—
—
1.5 V
5.0 V
15.0 V
50.0 V
150.0 V
500.0 V
—
—
25 V 2)
50 V 2)
150 V 2)
250 V 2)
300 V 2)
500 V 2)
50.0 µA –
0.5 mA –
5.0 mA –
50.0 mA –
500.0 mA –
5000.0 mA –
1.0 mA
5.0 mA
10.0 mA
70.0 mA
500.0 mA
3.0 A
5.0 A 3)
—
0.5 mA
5.0 mA
50.0 mA
500.0 mA
5000.0 mA
—
5.0 mA
10.0 mA
70.0 mA
500.0 mA
3.0 A
5.0 A 3)
Range To Range To
0.15 V –
0.5 V –
1.5 V –
5.0 V –
15.0 V –
50.0 V –
150.0 V –
500.0 V –
20 V 1)
50 V 2)
100 V 2)
150 V 2)
250 V 2)
250 V 2)
300 V 2)
500 V 2)
—
—
1.5 V
5.0 V
15.0 V
50.0 V
150.0 V
500.0 V
—
—
25 V 2)
50 V 2)
150 V 2)
250 V 2)
300 V 2)
500 V 2)
50 µA –
1.5 mA –
15 mA –
150 mA –
1.5 A –
15 A –
1.0 mA
5.0 mA
20.0 mA
150.0 mA
1.2 A
1.5 A 3)
12.0 A
15.0 A 3)
—
1.5 mA
15 mA
150 mA
1.5 A
15 A
—
5.0 mA
20.0 mA
150.0 mA
1.2 A
1.5 A 3)
12.0 A
15.0 A 3)