Rated Voltage: 100-240V AC~50Hz
Colour Temp: 6,000K
Class: I
IP Rating: IP54
Switching Cycles: 100,000
Total Lumens:
LEDFLSPIR10W/B 1,000 / 100 lm/W
LEDFLSPIR20W/B 2,000 / 100 lm/W
LEDFLSPIR30W/B 3,000 / 100 lm/W
LEDFLSPIR50W/B 5,250 / 105 lm/W
LEDFLSPIR100B 10,000 / 100 lm/W
Beam Angle: 120º
PIR Detection Distance: 2 - 8m
PIR Time Lag: 12s - 7m
Life Span: > 35,000 hours
Conforms to: EN60598, EN62031,
EN61500, EN61547
& EN55015
TECHNICAL INF RMATI N
GUARANTEE
Your GreenBrook PIR LED Slimline Floodlight
is guaranteed for 3 years from
the date of urchase.
This is in addition to your statutory rights.
PLEASE KEEP THESE INSTRUCTI NS
SAFE F R FUTURE REFERENCE
The motion sensor can be adjusted 340º from left to right
and adjustable through 180° up and down.
Pan +170,0,-170
Tilt +90,0, -90
DIAL FUNCTI N
MAINTENANCE:
Keep the glass front clean with a soft cloth. There are no
user serviceable parts contained within fitting. Any
disassembly or modification will invalidate the warranty.
DISP SAL:
At the end of the product’s life this product must not be
disposed of in landfill.
Local recycling guidance should be sought for disposal.
There are no hazardous materials contained therein.
ADJUSTING THE LUX C NTR L LEVEL
The Lux control module has a built-in photocell that detects
daylight and darkness.
( ) position denotes that the lamp will be turned on by the
PIR during day and night.
( ) position denotes that the lamp will be turned on by PIR
only at night.
A Lux range of 5 - 2000 Lux can be selected. The desired
Lux level can be achieved by adjusting the Lux knob.
ADJUSTING THE DURATI N TIME
The duration time is the length of time that the PIR Detector
switches the light ‘on’ after activation. The duration time
can be adjusted from approx 12 seconds up to 7 minutes.
Rotating the TI E knob from (+) to (-) will reduce the
duration time.
ADJUSTING SENSITIVITY
This control allows the user to adjust the level of movement
required, to trigger the device (+) will increase the
sensitivity of the unit. (-) will decrease the sensitivity of the
unit.
Lux: Sets the light
sensitivity of the sensor
Time: Sets the
interval time
Sens: Sets the
response level to movement
P SITI NING F SENS R