3
WETTED COMPONENTS
Steel,Aluminum,Zinc,Brass,NBR,PVC
RECOMMENDED USE
Transmissiondifferentials&heavierOils
DO NOT USE WITH
Chemicals,Acids,Waterbasedfluids&othercorrosive
mediaetc.
Thepumpisconstructedusingplatedsteelcomponents.Itshould
neverbeusedtotransferfluidsthatmaycausethepumptorust.
Keepworkareacleanandremoveanyexcessoilfromtools,
hands,andclothingafteruse.
BLP-02 BLP-03
Discharge Rate Upto60ml(2.14oz.)perstroke
Mechanism LeverAction
Hose Length 48”
Outlet Size 1/4”NPT
Container Size 25-50lbs/5Gal/20Litres 120lbs/16Gal/60Litres
Drum Cover Dia. 12”(310mm) 15”(381mm)
Pump Length 18”(450mm) 30”(760mm)
SPECIFICATIONS
Problem Possible Cause Corrective Action
Pumpfailstoprime Primingisneeded Pourafewdropsofthefluidbeingdispensed
intothepumpoutlet.
Startthepumpbymovingtheleverwith
severalquickstrokes
Pumpdoesnotdispensethefluid Blockageinthesuctionline Removethepumpfromthedrumandensure
thatsuctiontube&non-returnvalveisfreeof
anyblockage
TROUBLESHOOTING