GSM CWT5020 User manual


2
Thank you
Thank you for purchasing our products. Please read through this manual before using this product so as
to operate the product properly.
The GSM alarm system adopts the newest GSM network and Digital Signal Processing technology, and
is wi
dely used in security field. With SMS data transmission and voice platform of GSM network, it really
realizes wireless alarm control and remote managements and solves the limitation of wired data
transmission in telephone and wired network.
Perfect struc
ture, convenient installation, easy operation with wireless control keyboard are designed for
the idea of people
-
oriented, which will make you feel easy and comfortable while use this
system.
“
People is center, technology is first” is our company’s action
rule. Customer Satisfaction is our
consistent pursuit. Perfect system, excellent services, sincere attitudes will bring you a new enjoyment.

3
Contents
I.
SAFETY DIRECTIONS
......................
5
II.
INSTRUCTION
................................
........
6
2.1
Functions & Features of the GSM Alarm
System
6
2.2
Standard Pa
ckage list of the GSM Alarm
System
7
2.3
Specifications of Mainframe of the GSM
Alarm System
................................
................................
....
7
III.
INSTALLATION
................................
........
8
3.1
Alarm Host’s section figure
............................
8
3.2
Insert a valid SIM into the alarm host
.........
10
3.3
Run
................................
................................
....
10
IV.
SETUP STEPS
................................
......
10
4.1
Quick Guide
................................
.....................
10
4.2
Advance
Setup
................................
...............
12
4.2.1
Set 24 Hours Zone
................................
.........
12
4.2.2
Zone settings
................................
...................
12
4.2.3
Alarm voice call
................................
...............
12
4.2.4
Power fail alarm
................................
..............
12
4.2.5
Alarm delay time
................................
.............
12
4.2.6
Arm delay time
................................
................
12
4.2.7
Wired in types
................................
.................
13
4.2.8
Timer mode
................................
.....................
13
4.2.9
Restore factory
................................
...............
13
4.2.10
Erase RF sensor
................................
......
13
4.2.11
RF decoder
................................
................
13
4.2.12
GSM band setup
................................
......
13
V.
VIEW STATUS OF
HOST
....................
14
5.1
View status of Wired inputs
.........................
14
5.2
View the alarm records
................................
14
5.3
View the alarm records
................................
14
5.4
View Timers
................................
....................
14
5.5
View Wired in sms
................................
.........
14
5.6
View RF zone sms
................................
........
14
VI.
OPERATIONS OF THE
HOST
........
15
6.1
Control Output
................................
................
15
6.2
Arm/Disarm
................................
.....................
15
6.3
Sound alarm
................................
...................
15
6.4
Learn RF sensor
................................
............
15
6.5
Call and Hang up call
................................
...
15
VII.
OPE
RATIONS OF REMOTE
CONTROLLER
................................
............
16

4
7.1
Arm
................................
................................
....
16
7.2
Disarm
................................
..............................
16
7.3
Sou
nd alarm enable/disable
........................
16
7.4
Emergency alarm
................................
...........
16
VIII.
LCD ICON DISCRIPTION
.............
17
IX.
QUICK OPERATION COMM
AND
BY KEYBOARD
................................
...........
18
X.
SMS OPERATION COMMAN
D
.........
18
XI.
ENCODE THE WIRELESS
DETECTORS AND REM
OTE
CONTROLLER
................................
............
20

5
I.
Safety Directions
Safe Startup
Do not use
the system
when using
GSM equipment is prohibited or might
bring disturbance or danger.
Interference
All wireless equipment might interfere
network signals of
host
and influence its
performance.
Avoid Use at Gas Station
Do not use
the system
at a gas station.
Power off
Host
it near fuels or
chemicals.
Power it off near Blasting
Places
Please follow relevant restrictive
regulations. Avoid using the device i
n
blasting places.
Reasonable Use
Please install the product at suitable places
as described in the product documentation.
Avoid signal screening by covering the
mainframe.
Use Qualified Maintenance
Service
Maintenance can be carried out only by
qualifie
d maintainer.
Waterproofness
The product is not waterproof. Please
install it at dry places and keep it dry.

6
II.
Instruction
The GSM Alarm System is a new security protection solution special for home, house and office and other
applications. It based on Wir
eless GSM Communication network, intergrated
LCD
Menu display and Computer
technology and voice communication. When any sensor activated, it will Call&Send SMS to owners telephone
immediately.
The GSM Alarm System
equips with LCD and entire operation Menu
s Displayed, all operations and settings are visual
and intuitive! Also, the user can set it by PC through USB cables.
2.1
Functions & Features of the GSM
Alarm System
1.
GSM Frequency: Dual
-
Band
(900/1800MHz), Quad
-
Band is optional
(850/900/1800/1900Mhz)
;
2.
Can a
rmed, Bypass armed or disarmed by SMS or remote control or mainframe keyboard;
3.
Automaticed send SMS Alert and dial to the pre
-
set cellphone when any sensor activated;
4.
Equips with 4 Wired Zones,
NC/NO, and Zone Name is editable;
5.
Equips with 8 Wireless Zones
, Normal/Bypass mode and Zone Name is editable, 3 24
-
Hour zones for Panic
button, smoke and gas leakage sensor;
6.
Supports 10 alarm telephones and 20 Alarm Records for owner review;
7.
Supports 6 timing points, 4 pre
-
set timing points for customer choice;
8.
Suppo
rts armed delay to give enough time to you go out the home, the delay time is editable by user;
9.
Equips with 1 relay output, it like a switch, use for driving DVR, light, gate or other electric appliances once the
system activated. It can be disable and ena
ble by user;
10.
The Keypad can use as a dialer, the functions like the Cellphone;
11.
The external power failure&recov
ery alert function is optional
;
12.
Supports wiretap through external mirophone to special user for high
-
sensitivity listen by RJ
11
connector is
ava
ilable;

7
13.
Supports internal Speaker to special user for two
-
way voice communication by RJ
11
connector;
14.
It is Compatible with PT2262/2264 wireless IC, EV1527 is optional;
15.
Standby internal rechargeable battery which can last 10 hours;
16.
Based on the GSM communi
cation network and Operation Menu Display technology, apply to wide range
situations;
2.2
Standard Package list of the GSM Alarm System
Mainframe X1
Remote contol X2
Wireless PIR Motion Sensor X1
Wireless Door magnetic Sensor X1
Wired Siren X1
AC/DC
Adaptor
X1
PC Programmer Tool CD X1
User Manual X1
2.3
Specifications of Mainframe of the GSM Alarm System
Rated Voltage: 12VDC 1.5A
Working temperature:
-
10
℃
~
+60
℃
Storage temperature:
-
20
℃
~
+60
℃
Relative humidity:
10
-
90%, No condensation
Work frequency
:
GSM900,1800Mhz or 850/900/1800/1900MHz
Communication protocol:
GSM PHASE 2/2+ (include data service)
Wireless sensor receiving frequency: 433+/
-
0.5MHz
Wired Zones: 4
Wireless Zones: 8
24
-
Hour Wireless Zones: 3(Special for Panic Button, Smoke and Gas Sen
sor)
Related Voltage of the Relay: 5V
Effective distance of wireless transmission: 100 m (Open area)
Battery: Built
-
in lithium
-
ion battery: 800mAh 3.7V
Standby time Approx. 10hours (depending on the network condition)
Net Weight: 1.60Kg

8
III.
The host
Inst
all
ation
3.1
Alarm Host’s section figure
Speaker
menu button
LCD display
Keyboard
Power switch
SIMcard socket
USB

9
Interface1
(RJ11 connector,Telephone cable or
CAT5 cable)
Interface2
(RJ11 connector,Telephone cable or
CAT5 cable)
PIN1
M
icrophone positive electrode
PIN1
GND
PIN2
M
icrophone negati
ve electrode
PIN2
GND
PIN3
PIN3
Wired sensor input 3
PIN4
Output relay positive electrode
(Relate voltage:3A/250VAC)
PIN4
Wired sensor input 2
PIN5
PIN5
Wired sensor input 1
PIN6
Output relay negative electrode
(Relate voltage:3A/250VAC)
PIN6
Wi
red sensor input 0
Tips
:
The Microphone is the same as computer
microphone, you can use the computer microphone
to it;
Tips
:
Wired sensor input can connect Temperature
sensor, Water leakage sensor, etc.

10
3.2
Insert a valid SIM into the alarm host
Before in
stalling the host, remove the SIM slot cover with screwdriver and insert SIM card.
3.3
R
un
Make sure that the power supply is connected correctly, and turn on the host power switch. The
alarm
host will search
the GSM network automatically within 25 seconds aft
er it is started. Then the LCD display turns on and shows the
status of arm, disarm, GSM signal etc.
IV.
Setup
steps
4.1
Q
uick Gui
de
Login system
1
Press “
OK
”
button
, input password
,
The initial password is
000000
(must be numbers).
Set the mobile phone n
umber
2
After enter Main menu, please select
”
Setup
”
,
and select
“
Store phones
”
,
press
”
OK
”
to add phones by
keyboard, while
delete phones, you can press
“
UP
”
button to delete phone numbers
.
Y
ou can add 10
mobile phone numbers.
Main menu
0 view
1 Operation
>
2 Setup
Setup
0 24 hours zone
1 Zone settings
>
2 Store phones
Store phones
0
:
-
>
1
:
-
>
2
:
-
>

11
Set time
date
of the alarm host
3
please
enter
”
Setup
”
menu,
and select
“
Time date
”
,press
“
OK
”
to set time by keyboard
Change
login
password
4
please enter
”
Setup
”
menu,
and select
“
Password
”
,press
“
OK
”
to set
password
by keyboard
Main menu
0 view
1
Operation
>
2 Setup
Setup
0 24 hours zone
1 Zone settings
2 Store phones
>
3 Time date
Time date
00/00/00 00:00
Main menu
0 view
1 Operation
>
2 Setup
Setup
>
4 Pa
ssword
5 Alarm voice call
6 Power fail alarm
7 Alarm delay tim
Password

12
4.2
Advance
Setup
4.2.1
Set 24 Hours Zone
please enter
”
Setup
”
menu,
and select
“
24 hours zone
”
,
Set the selected wired or
RF zones as 24
hours
Z
one or not
4.2.2
Zone settings
please enter
”
Setup
”
menu,
and select
“
zone settings
”
,
Set
the selected wired or RF
zones
Bypass armed or
enable, enable means it
can be armed
.
4.2.3
Alarm voice call
please enter
”
Setup
”
menu,
and select
“
Alarm voice call
”
,
press
”
OK
”
to
set
host
dial
to the pre
-
set
mobile
phone
when
alarm or not
.
4.2.4
Power fail al
arm
please enter
”
Setup
”
menu,
and select
“
Power fail
alarm
”
,
press
”
OK
”
to set
external AC
power failure and recoverd
need the
host
send SMS to
alarm or not.
4.2.5
A
la
rm delay time
please enter
”
Setup
”
menu,
and select
“
Alarm delay time
”
,
press "OK
”
to set Alarm delay
time,
in the time
host
will
not
send
SMS
when
alarm,
I
n
this way,
you
have a
enough
time to set in
dis
arm mode
when
you
enter
the monitor
area.
4.2.6
Arm delay time
please enter
”
Setup
”
menu,
and select
“
Arm delay time
”
,
press "OK
”
to set Arm delay
time,
in the time
host
will
not
send
SMS
when
alarm
,
I
n
this way,
you
have a
enough
time to set in arm mode when
you
leave the monitor area.
24 Hours zo
ne
>
0 Wired znones
1 RF zone
Zone settings
>
0 Wired znones
1 RF zone
Alarm voice call
●
Enable
○
Disable
Power fail alarm
●
Enable
○
Disable
Arm delay time
●
0 s
○
30 s
○
60 s
○
90 s
Arm delay time
●
0 s
○
30 s
○
60 s
○
90 s

13
4.2.7
Wired in types
please enter
”
Setup
”
menu,
and select
“
Wired in types
”
,
press "OK
”
to set
the 4
wired sensor NO. or NC
4.2.8
Timer mode
please enter
”
Setup
”
menu,
and select
“
Timer mode
”
,
press "OK
”
to set the 4
Timer mode
of auto
-
arm/
disarm
.
Mode1:
9
: 00
to arm
——
17
:
3
0
to disarm
Mode
2
:
9
: 00
to arm
——
12
:
0
0
to disarm
13
:
3
0
to arm
——
17
:
3
0
to
disarm
Mode
2
:
9
: 00
to arm
——
12
:
0
0
to disarm
13
:
3
0
to arm
——
17
:
3
0
to disarm
22: 30 siren alarm enable
6:30 siren alarm disable
Mode
4
:
18
:
3
0
to arm
——
7
:
4
0
to disarm
4.2.9
Restore factory
please enter
”
Setup
”
menu,
and select
“
Restore factory
”
,
press "O
K
”
to
Rese
t
the
host
4.2.10
Erase RF sensor
please enter
”
Setup
”
menu,
and select
“
Erase RF sensor
”
,
press "OK
”
to
remove all of wireless sensors
4.2.11
RF decoder
please enter
”
Setup
”
menu,
and select
“
RF
decoder
”
, press
"OK
”
to
select EV1527 or
PT2262
/64
, default is
P
T2262, the host support
two
kinds of
wireless
sensor that
base on
EV1527 or PT2262
/64
wirless IC
.
B
ut o
nly one
of
type
s
can be active
at a time
.
4.2.12
GSM band setup
If your host support
GSM 4
band, and
it i
s used in
850M
or
1900M GSM
network, please select
“
GSM 850M
”
Wired in types
00:
-
>
No.
type
01:
-
>
No.
type
02:
-
>
No.
type
03:
-
>
No.
type
Timer mode
●
Mode1
○
Mod
e2
○
Mode3
○
Mode4
RF decoder
●
EV1527
○
PT2262/64
GSM badn setup
●
Default
○
GSM_850M

14
V.
View status of
Host
5.1
View status of
Wired inputs
please enter
”
View
”
menu,
and select
“
Wired inputs
”
,
press "OK
”
to
view
the
wired inputs triggered or
not
5.2
View the alarm records
please ente
r
”
View
”
menu,
and select
“
Alarm record
”
,
press "OK
”
to
view the
lastest 20 alarm records
5.3
View the alarm records
please enter
”
View
”
menu,
and select
“
GSM status
”
, press
"OK
”
to
view the
gsm signal, more than 17 is good, less
than is poor,
and you can
view t
he IMEI code
of
gsm
mod
ule
.
5.4
View
Timers
please enter
”
View
”
menu,
and select
“
Timers
”
, press
"OK
”
to
view the
timers
you have set
5.5
View
Wired in sms
please enter
”
View
”
menu,
and select
“
Wired in sms
”
,
press "OK
”
to
view the
sms alert contents
of the
wired zones that
you have
set
.
5.6
View
RF zone sms
please enter
”
View
”
menu,
and select
“
RF zone
sms
”
,
press "OK
”
to
view the
sms alert contents of the
RF
zones that you have
set.
Wired inputs
Wired in0
-
>
No
rmal
Wired in1
-
>
No
rmal
Wired in2
-
>
No
rmal
Wired in3
-
>
No
rmal
Alarm records
-
>
Alarm record 0
Ala
rm record 1
Alarm record 2
Alarm record 3
Wired inputs
Wired in0
-
>
No
rmal
Wired in1
-
>
No
rmal
Wired in2
-
>
No
rmal
Wired in3
-
>
No
rmal
Wired in sms
-
>
Wired in sms 0
Wired in sms 1
Wired in sms 2
Wired in sms 3
RF zone
sms
-
>
RF zone in sms 00
RF zone in sms 00
RF zone in sms 00
RF zone in sms 00

15
VI.
Operation
s
of the host
6.1
Control Output
please enter
”
Operation
”
menu,
and select
“
Relay
drivers
”
, press "OK
”
to
control output on or off
6.2
Arm/Disarm
please enter
”
Operation
”
menu,
and select
“
Arm / Disarm
”
,
press "OK
”
to make the
host in
full
arm or disarm or
at house
(bypass armed)
mode
.
6.3
Sound alarm
please enter
”
Operation
”
menu,
and select
“
Sound
alarm
”
, press "OK
”
to
set
the siren
en
able or disable
6.4
Learn RF sensor
please enter
”
Operation
”
menu,
and select
“
Learn RF
sensor
”
, press "OK
”
to
start,
after select
”
yes
”
,
you can
trigger a wireless sensor ,
then you
will hear
“
di,di
”
sound for learn successflly
6.5
Call
and Hang up call
please enter
”
Operation
”
menu,
and select
“
Call
”
, press
"OK
”
and
keyed in
phone numbers and press
“
ok
”
to dial
, if
you need to hang up the call , you
can
enter
”
Operation
”
menu,
and
sel
ect
“
Hang up call
”
Relay drivers 0
●
on
○
off
Arm/Disarm
●
Full Arm
○
Disarm
○
At House
Sound alarm
●
on
○
off
Learn RF sensor
●
Yes
○
No

16
VII.
O
peration
s
of
remote controller
R
emote controller is an accessory of
the host
,
It can remote
control host to
arm/disarm
,
sound
alarm enable/disable
and
it
provide
emergen
cy button for urgent status.
7.1
Arm
Press “
” on remote contr
oller, the host will make “di” sound,
the LCD display is twinkling. the host enters into arm mode
and the “
” is on.
7.2
Disa
rm
Press “
” on remote controller, the host will make
“di
~
,di
,di,di
” sound, the LCD display is twinkling. the host enters into
dis
arm mode and the “
” is on.
7.3
Sound alarm enable/disable
Press “
” on remote co
ntroller, the host will make “
di
” sound, the LCD display is twinkling
and the
”
”
is on
, host
is in at h
ouse mode.
and
the
siren alarm
is
enabled
and
”
”
is on
,
next
press
“
”
button
agina
,
the host will
make “
di
~
,di,di,di
” sound
,
the LCD display is twinkling
and the
”
”
is on
,
the
siren alarm is
di
abled
7.4
Emergency alarm
When an emergency alarm occurs, pre
ss “
” and the host will enter into emergency alarm status
,
immediately
,
the
siren will alarm for 90 seconds to inform the neighbors.
A
nd
automatically
send SMS of
“
Emergency alarm”
to
the
preset alarm phone numbers
.
Arm button
Disarm button
A
t house arm
button
emergen
cy button
Antenna

17
VIII.
LCD
ICON
discription
Host
is
in arm mode
Host
is
in diarm mode
Host
is
in at house arm mode
T
he
siren alarm is enabled
T
he
siren alarm is
di
abled
GSM signal
Learn RF sensor
Power supply by external
AC power
Power supply by internal battery

18
IX.
Q
uick operation
command by keyboard
Operations
Keyboard
Command
Arm
11#
Disarm
00#
At house
12#
S
iren enable
31
#
S
iren disable
30#
E
mergency
alarm
999#
X.
SMS
Operation
command
Operations
Command
Arm
BF
Disarm
CF
Query system
status
dayrp
CS<n><phone
numbers
>
(n=0~9)
Set
te
n
mobile phone
numbers for
host
Example
:
Set 1388888888 as the first mobile phone number for
host
S
end sms:
CS01388888888
Query all phone numbers
CS?
CS<n>
(n=0~9)
Delete phone numbers
Exampl
e
:
Delete CS9
mobile phone number

19
S
end sms: CS
9
PW<
old password
>, <
new password
>
Change password
Example: The initial password is
000000
, if you want to set
123456
as the new
password,
Send SMS:
PW000000,123456
indly
<
time
(
second
)
>
Set disarm delay time
Example:
set disarm delay time is 20
Send SMS:
indly20
Set arm d
elay
time
outdly
<
time
(
second
)
>
S
<n>
<
message
>
(n=00~03)
Set
4 Wired Zones
alarm
s
ms
Example
:
Set
‘”
temperature alarm
”
as the
alarm sms of wired input 0
S
end sms:
S00
temp
erature alarm
S
<n>
<
message
>
(n=04~07)
Set
4 Wired Zones
recover
s
ms
(
input type must be
“
LEVEL
”
)
Example
:
Set
‘”
temperature
recover
”
as the
recover
sms of wired input 0
S
end sms: S0
4
temperature alarm
Set emergency alarm sms
S08<
message
>
S
<n>
<
message
>
(n=09~20)
Change
11
Wireless Zones
alarm sms
Example
:
Set
“
door sensor
alarm
”
as the
alarm sms of
Wireless Zones
1
S
end sms: S0
9
door sensor alarm
Output close
IOOH0
Output open
IOOL0

20
XI.
Encode the wireless detectors and Remote controller
Wireless address code of product (A0 to A7)
Note: You can see the code (A0
-
A7) from PCB in the products
.
Name
Zones
A
t house arm
D0
(13)
D1
(
12
)
D2
(11)
D3
(10)
Door
Zone01
Bypass
1
0
1
0
PIR
Zone02
Bypass
0
1
1
0
Temperature
Zone03
Bypass
1
1
1
0
Smoke
Zone04
Default is
24 hour zone
Bypass
0
1
0
1
Gas
Zone05
Default is
24 hour zone
Bypass
1
1
0
1
Water
Zone06
Bypass
0
0
1
1
Glass
Zone07
Bypass
1
0
1
1
Glass(
external
)
Zone08
Bypass
0
1
1
1
PIR(
external
)
Zone09
Working
1
1
1
1
Door(
external
)
Zone10
Working
1
1
0
0
Smoke(
external
)
Zone11
Default is
24 hour zone
Working
1
0
0
1
Table of contents