BMK Operating Instructions
17
6.3.1 Heating Circuit
menu (User)
BS-06-03-01-00-01-BAEN
The Heating Circuit menu allows you to enter the settings for
the various heating circuits.
7) Options →Auto Heating circuit is switched ON/OFF according to demand and timer programme.
→Off The heating circuit is switched off.
→Constant The pump runs continuously; with mixer-valve heating circuits, the mixer valve is not operated
8) Modulation to "daytime required temperature" is only possible in conjunction with a room stat or room controller; raising or
lowering the required temperature shifts the heating curve up or down accordingly.
9) Modulation to "night-time required temperature" is only possible in conjunction with a room stat or room controller; in addition,
the outside temperature must be below that set in menu option "Night OFF OT" (hysteresis 2°C)
10) Options →0%No room effect programmed
→25% Modulation of room temperature based 25% on room temperature and 75% on outside temperature.
→50% Modulation of room temperature based 50% on room temperature and 50% on outside temperature.
→75% Modulation of room temperature based 75% on room temperature and 25% on outside temperature.
→100% Modulation of room temperature based 100% on room temperature.
→T 1°C If the required room temperature is exceeded by 1°C the heating circuit pump is switched off.
→T 2°C If the required room temperature is exceeded by 2°C the heating circuit pump is switched off.
→T 3°C If the required room temperature is exceeded by 3°C the heating circuit pump is switched off.
11) A higher heating characteristic figure produces a higher required flow temperature at the same outside temperature
12) If the temperature drops below the set temperature during the low-temperature phase, the boiler heats to the required night-time
temperature.
13) The set outside temperature is exceeded during the heating phase, the heating circuits are switched off.
6.3.2 Hot Water
menu (User)
BS-06-03-02-00-01-BAEN
The Hot Water menu allows you to enter the settings for the
various domestic hot water circuits.
14) Options →Auto Charging pump is switched ON/OFF according to demand and timer programme.
→Off The charging pump is switched off.
→Constant The charging pump runs continuously
15) All charging times programmed in the "DHW timer programme" are active when the programme is set to "Normal".
16) All charging times programmed in the "DHW summer timer programme" are active when the programme is set to "Hot Water".
17) Options →No During charging of DHW cylinder, heating circuits can be enabled.
→Yes During charging of DHW cylinder, heating circuits cannot be enabled (factory setting =
recommended).
7)
Heating circuit control status
Facility for setting heating and low-temperature times
8)
Facility for setting daytime required temperature
9)
Facility for setting night-time required temperature
10)
Facility for setting room effect/thermostat function
11)
Facility for setting heating characteristic
12)
Changeover from low-temperature mode to night-time set temperature
13)
Outside temperature mode cut-off for heating circuits
14)
Hot water circuit control status
15)
Facility for setting hot water charging times
16)
Facility for setting summer hot water charging times
Facility for setting required hot water temperature
17)
Facility for setting hot water priority