18
6.2.1 Customer menu
PH-01
Ash emptied ...................................
Menu option Ash emptied →Press "YES" to confirm after emptying ash box
Ash Warning ...................................
Maximum time in hours until ash warning is triggered →0h = Ash warning deactivated
De-ash.............................................
manual deashing with automatic Ash suction system (turns automatically off)
3)
Fuel .................................................
For selecting fuel setting →Sets the type of fuel being used
4)
Release HCR 0-2............................
the state of operating of trunk blink system is influenced
Fill auger .........................................
Manual filling of outfeed auger→A1 + G1
De-ash curfew.................................
no deashing while the blocking time is running
Ash-factor........................................
the adaption of ash suctions interval in 0,1 steps (high Number = more suction)
Language ........................................
Menu language setting
back to Customer level..............................
see Chapter 6.2
INFOBOX
3) without Corn/Miscanthus revetment Hack chips / pellets
with Corn/Miscanthus revetment Hack chips / pellets / barley / triticale / miscantus
4) AUTO.................. the trunk blink system will be turned automatically turned ON/ OFF;
OFF..................... the trunk blink system is turned off;
NONSTOP .......... the trunk blink system function isn’t opened;
6.2.2 Heating Circuit
BS-01
5)
Run pump .......................................
Heating circuit control status
Time program..................................
Facility for setting heating and low-temperature times
6)
Target temp. day.............................
Facility for setting daytime required temperature
7)
Target temp. night...........................
Facility for setting night-time required temperature
8)
Room effect.....................................
Facility for setting room effect/thermostat function
9)
Heat Curve......................................
Facility for setting heating characteristic
10)
Night off OT.....................................
Changeover from low-temperature mode to night-time set temperature
11)
Turn off OT......................................
Outside temperature mode cut-off for heating circuits
back to Customer level..............................
see Chapter 6.2
INFOBOX
5) AUTO.................. Heating circuit is switched ON/OFF according to demand and timer programme.
OFF..................... The heating circuit is switched off.
NONSTP ............. The pump runs continuously; with mixer-valve heating circuits, the mixer valve is not operated.
6) Modulation to "daytime required temperature" is only possible in conjunction with a room stat or room controller; raising or lowering
the required temperature shifts the heating curve up or down accordingly.
7) Modulation to "night-time required temperature" is only possible in conjunction with a room stat or room controller; in addition, the
outside temperature must be below that set in menu option "Night OFF OT" (hysteresis 2°C).
8) 0% – 100%.......... In case of am high outside temperature (“plus degrees”) the pre temperature will be raised to the whished room
temperatures through an higher room influence;
T1C°- T3°C ........ the overshoot of room target temperature, the heating circle will be turned off;
9) A higher heating characteristic figure produces a higher required flow temperature at the same outside temperature.
10) If the temperature drops below the set temperature during the low-temperature phase, the boiler heats to the required night-time
temperature.
11) The set outside temperature is exceeded during the heating phase, the heating circuits are switched off.