H3C A3600 Series User manual

HP A3600 Series Ethernet Switches
Installation Manual

Organization
HP A3600 Series Ethernet Switches Installation Manual is organized as follows:
Chapter Contents
1 Product Overview Introduces the characteristics and technical
specifications of S3600 Series Ethernet Switches.
2 Preparation Introduces the installation preparation and
precaution of S3600 Series Ethernet Switches.
3 Installation Introduces the procedures to install an S3600 Series
Ethernet Switch, including the setup of the
mainframe, cards and cables.
4 Starting up the Switch at the Initial Boot Introduces the booting process of an S3600 Series
Ethernet Switch, including the power-on booting of
the switch and the system initialization.
5 Loading Boot ROM and Host Software Introduces how to load BootROM and host software
for an S3600 Series Ethernet Switch.
6 Maintenance and Troubleshooting Introduces the problems that might occur during the
installation and the booting of an S3600 Series
Ethernet Switch and the related solution.
7 Appendix Lightning Protection of the Switch Introduces lightning protection of S3600 Series
Ethernet Switches.
Conventions
The manual uses the following conventions:
I. GUI conventions
Convention Description
< > Button names are inside angle brackets. For example, click <OK>.
[ ] Window names, menu items, data table and field names are inside square
brackets. For example, pop up the [New User] window.
/Multi-level menus are separated by forward slashes. For example,
[File/Create/Folder].
II. SymbolsConvention Description
Warning Means reader be extremely careful. Improper operation may cause bodily
injury.
Caution Means reader be careful. Improper operation may cause data loss or
damage to equipment.
Note Means a complementary description.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the proper storage, use and
disposal of this product, national laws and regulations must be observed.

Chapter 1 Product Overview
1.1 Introduction
HP S3600 Series Ethernet Switches developed by HP are high-performance, high-density, easy-to-install, NMS-manageable
intelligent Ethernet switches which support wire-speed Layer 2/3 switching.
Table 1-1 lists the models of HP S3600 Series Ethernet Switches.
Table 1-1 Models of the S3600 series
Subseries Model Power
supply
Number of
service
ports
Number of
100 Mbps
ports
Number of 1000
Mbps uplink ports
Number of
Console
ports
HP A3600-SI
A3600-24
SI AC 28 24 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
A3600-
24TP SI AC 28 24 × 10Base-
T/100Base-TX
Ethernet ports
2 × 1000Base-X
SFP ports, 2 ×
10/100/1000Base-
T Ethernet ports
1
A3600-48
SI AC 52 48 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
HP A3600-
POE-SI
A3600-
24-POE
SI AC/DC 28 24 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
A3600-
48-POE
SI AC/DC 52 48 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
HP A3600-EI
A3600-24
EI AC/DC 28 24 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
A3600-
24-SFP EI AC/DC 28 24 x 100Base-
X SFP ports
2 × 1000Base-X
SFP ports, 2 ×
10/100/1000Base-
T Ethernet ports
1
A3600-48
EI AC/DC 52 48 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
HP A3600-
POE-EI
A3600-
24-POE
EI AC/DC 28 24 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
A3600-
48-POE
EI AC/DC 52 48 × 10Base-
T/100Base-TX
Ethernet ports
4 × 1000Base-X
SFP ports 1
Note:
The A3600-24-POE SI, A3600-24-POE EI, A3600-48-POE
SI, and A3600-48-POE EI provides over-temperature
protection mechanism. When the internal temperature exceeds
65°C (149°F), they will stop providing power from all ports.
When the temperature is below 60°C (140°F), they will
continue to provide power from all ports.
Only the recommended PoE power supply can be used for
the A3600-24-POE SI, A3600-24-POE EI, A3600-48-POE SI,

and A3600-48-POE EI. The –48 VDC from the equipment room
cannot be used directly. Otherwise, devices may be damaged.
1.2 A3600-24 SI
1.2.1 Front Panel
I. Schematic diagram
The A3600-24 SI provides twenty-four 10Base-T/100Base-TX auto-sensing Ethernet ports, four 1000Base-X SFP ports, and
one Console port on the front panel, as shown in Figure 1-1.
(1) 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs
(2) 1000Base-X SFP port status LEDs (3) AC power LED
(4) Mode LED (5) Mode button
(6) 7-segment digital LED (7) Console port
Figure 1-1 Front panel of the A3600-24 SI
II. LEDs
The A3600-24 SI provides one AC power LED, one mode LED, one 7-segment digital LED, twenty-four 10Base-T/100Base-TX
auto-sensing Ethernet port status LEDs, and four 1000Base-X SFP port status LEDs on the front panel. You can learn how the
switch operates by observing the LEDs listed in Table 1-2.
Table 1-2 LEDs on the front panel of the A3600-24 SI
LED Mark Status Indication
Mode LED Mode
Speed Solid green Rate information of 10Base-T/100Base-TX
auto-sensing Ethernet ports, and
1000Base-X SFP ports
Duplex Solid yellow Duplex information of 10Base-T/100Base-
TX auto-sensing Ethernet ports, and
1000Base-X SFP ports
AC Power
LED PWR
Solid green The switch is started normally.
Flashing green (1 Hz) The system is running a power-on self-test
(POST) or downloading software.
Solid red The system fails a POST or a fault occurs.
Flashing yellow (1 Hz) Some ports fail a POST or malfunctions
occur.
OFF The power is disconnected.
10Base-
T/100 — Speed Green ON A 100 Mbps link is present.

LED Mark Status Indication
Base -TX
port status
LED
Flashing Data is being received/sent on the port.
Yellow ON A 10 Mbps link is present.
Flashing Data is being received/sent on the port.
Flashing yellow (3
Hz) The port fails the POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode.
Flashing Data is being received/sent on the port.
Yellow ON The port is operating in half duplex mode.
Flashing Data is being received/sent on the port.
Flashing yellow (3
Hz) The port fails the POST.
OFF No data is being received/sent on the port.
1000
Base-SFP
port status
LED
—
Speed
Green ON A 1000 Mbps link is present.
Flash Data is being received/sent on the port.
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode.
Flash Data is being received/sent on the port.
Flashing yellow (3
Hz) The port fails the POST.
OFF The port is not connected.
PoE mode
Flashing green (3
Hz) The port fails the POST.
OFF ––
Status
LED of the
1000Base-
X SFP
port
serving as
a fabric
port
—
Speed
Green ON The port is connected, and the device is in
an IRF loop fabric.
Flashing Data is being received/sent on the port.
Yellow ON The port is connected, and the device is in
an IRF chain fabric.
Flash Data is being received/sent on the port.
Flashing green (3Hz) A fault occurs to Fabric.
Flashing yellow (3
Hz) The port fails the POST.
OFF The port is not connected.
Duplex Green ON The port is in full duplex mode.
Flashing Data is being received/sent on the port.

LED Mark Status Indication
Flashing yellow (3
Hz) The port fails the POST.
OFF The port is not connected.
PoE
Flashing yellow (3
Hz) The port fails the POST.
OFF ––
7-segment
digital LED Unit
POST
running The PWR LED
flashes green Displays the POST test ID (in the range of
1 to 9).
POST failed
The PWR LED
flashes yellow Flashes the POST test ID of the failed test.
The PWR LED is
solid red
Software
downloading The PWR LED
flashes green A bar rotates clockwise around the LED.
Fan failed The PWR LED is
solid red Displays “F”.
Unit ID Button released Displays the unit ID in the fabric; and
displays “1” if there is only one unit.
III. Attributes of the 10Base-T/100Base-TX Ethernet ports
Table 1-3 Attributes of the 10Base-T/100Base-TX Ethernet Ports on the A3600-24 SI
Attribute Description
Connector RJ-45
Number of ports 24
Rate
10 Mbps, half duplex/full duplex
100 Mbps, half-duplex/full duplex
MDI/MDI-X auto-sensing
Standard IEEE 802.3u
Transmission distance over the
selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP)
cable
IV. Console port
The A3600-24 SI provides one EIA/TIA-232 compliant Console port for local or remote configuration. Table 1-4 lists the
attributes of the Console port.
Table 1-4 Console port attributes
Attribute Description
Connector RJ-45
Standard Asynchronous EIA/TIA-232
Baud rate 9600 bps (default)

Attribute Description
Service
Connection to the ASCII terminal
Connection to the serial interface of a local terminal (a PC for example) or to a remote
terminal through a pair of modems), where terminal emulation program is run
V. Attributes of the 1000Base-X SFP ports
The A3600-24 SI provides four 1000Base-X SFP ports (numbered from 25 to 28) on its front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.
Table 1-5 1000Base-X SFP modules
Type Model
SFP optical
module
1000Base-X SFP module
SFP-GE-SX-MM850-A
SFP-GE-LX-SM1310-A
SFP-GE-LH40-SM1310
SFP-GE-LH40-SM1550
SFP-GE-LH70-SM1550
SFP electrical interface
module SFP-GE-T
Note:
The types of 1000Base-X SFP modules may be subject to
changes without notice. Consult HP marketing personnel or
technical support personnel to obtain the latest information
about SFP modules.
For specifications of SFP modules, refer to HP Low End
Series Ethernet Switches Pluggable Modules Manual.
1.2.2 Rear Panel
I. Schematic diagram
The A3600-24 SI provides an AC power socket and a grounding screw on its rear panel, as shown in Figure 1-2.
(1) AC power socket (2) Grounding screw
Figure 1-2 Rear panel of the A3600-24 SI
II. Power system
The following gives the input voltage specifications for the A3600-24 SI:
Rated voltage range: 100 VAC to 240 VAC, 50/60 Hz

Input voltage range: 90 VAC to 264 VAC, 47 to 63 Hz
1.3 A3600-24TP SI
1.3.1 Front Panel
I. Schematic diagram
The A3600-24TP SI provides twenty-four 10Base-T/100Base-TX auto-sensing Ethernet ports, two 1000Base-X SFP ports, two
10/100/1000Base-T auto-sensing Ethernet ports, and one Console port on the front panel, as shown in Figure 1-3.
(1) 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs
(2) 1000Base-X SFP port status LEDs
(3) 10/100/1000Base-T auto-sensing Ethernet port status LEDs
(4) Console port
(5) 7-segment digital LED (6) AC power LED
(7) Mode LED (8) Mode button
Figure 1-3 Front panel of the A3600-24TP SI
II. LEDs
The A3600-24TP SI provides one power LED, one DC power LED, one mode LED, one 7-segment digital LED, twenty-four
10Base-T/100Base-TX Ethernet port status LEDs, two 1000Base-X SFP port status LEDs, and two 10/100/1000Base-T auto-
sensing Ethernet port status LEDs. You can learn how the switch operates by observing the LEDs listed in Table 1-6.
Table 1-6 LEDs on the front panel of the A3600-24TP SI
LED Mark Status Indication
AC power
LED PWR
Solid green The switch is started normally.
Flashing green (1Hz) The system is running a POST or
downloading software.
Solid red The system fails the POST or a fault occurs.
Flashing yellow (1Hz) Some ports fail a POST or malfunctions
occur.
OFF The power is disconnected.
Mode LED Mode Speed Solid green Rate information of 10Base-T/100Base-TX
Ethernet ports, and 1000Base-X SFP ports.

LED Mark Status Indication
Duplex Solid yellow Duplex information of 10Base-T/100Base-
TX Ethernet ports, and 1000Base-X SFP
ports.
10Base-
T/100Base-
TX port
status LED
—
Speed
Green ON A 100 Mbps link is present.
Flashing Data is being received/sent on the port.
Yellow On A 10 Mbps link is present.
Flashing Data is being received/sent on the port.
Flashing yellow
(3Hz) The port fails a POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode.
Flashing Data is being received/sent on the port.
Yellow ON The port is operating in half duplex mode.
Flashing Data is being received/sent on the port.
Flashing yellow
(3Hz) The port fails a POST.
OFF No data is being received/sent on the port.
1000Base-
X SFP port
status LED —
Speed
Green ON A 1000 Mbps link is present.
Flashing Data is being received/sent on the port
.
Flashing yellow
(3Hz) The port fails a POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode.
Flashing Data is being received/sent on the port.
Flashing yellow
(3Hz) The port fails a POST.
OFF No link is present.
PoE
Flashing green
(3Hz) The port fails a POST.
OFF —
10/100/
1000Base-
T Ethernet
port status
LED
—
Speed
Green ON A 1000 Mbps link is present.
Flashing Data is being received/sent on the port.
Yellow ON A 10/100 Mbps link is present.
Flashing Data is being received/sent on the port.
Flashing yellow
(3Hz) The port fails a POST.
OFF No link is present.
Duplex Green ON The port is operating in full duplex mode.
Flashing Data is being received/sent on the port.

LED Mark Status Indication
Yellow ON The port is operating in half duplex mode.
Flashing Data is being received/sent on the port
Flashing yellow
(3Hz) The port fails POST.
OFF No data is being received/sent on the port.
7-segment
digital LED Unit
POST
running The PWR LED
flashes green Displays the POST test ID (in the range of 1
to 9).
POST
failed
The PWR LED
flashes yellow Flashes the POST test ID of the failed test.
The PWR LED is
solid red
Software
loading The PWR LED
flashes green A bar rotates clockwise around the LED.
Fan failure The PWR LED is
solid red Displays “F”.
Unit ID Button released Displays the unit ID in the fabric, and
displays “1” if there is only one unit.
III. Attributes of the 10Base-T/100Base-TX Ethernet ports
The A3600-24TP SI provides twenty-four 10Base-T/100Base-TX Ethernet ports (numbered from 1 to 24) on the front panel. For
attributes of these ports, see Table 1-3.
IV. Attributes of the 1000Base-X SFP ports
The A3600-24TP SI provides two 1000Base-X SFP ports numbered 25 and 26 on the front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.
Note:
The types of 1000Base-X SFP modules may be subject to
changes without notice. Consult HP marketing personnel or
technical support personnel to obtain the latest information
about SFP modules.
For specifications of SFP modules, refer to HP Low End
Series Ethernet Switches Pluggable Modules Manual.
V. Attributes of the 10/100/1000Base-T Ethernet ports
The A3600-24TP SI can provide two 10/100/1000Base-T Ethernet ports numbered 27 and 28 on the front panel. For attributes
of these two ports, see Table 1-7.
Table 1-7 Attributes of the 10/100/1000Base-T Ethernet ports on the A3600-24TP SI
Attribute Description
Connector RJ-45
Number of ports 2

Attribute Description
Rate
10/100 Mbps, half duplex/full duplex
1000 Mbps, full duplex
MDI/MDI-X auto-sensing
Standard IEEE 802.3u
IEEE 802.3ab
Transmission distance over the
selected medium 100 m (328.08 ft) over the category-5 unshielded twisted pair (UTP)
cable
VI. Console port
The A3600-24TP SI provides one EIA/TIA-232 compliant Console port for local or remote switch configuration. For the
attributes, see Table 1-4.
1.3.2 Rear Panel
I. Schematic diagram
The A3600-24TP SI provides an AC power socket and a grounding screw on the rear panel, as shown in Figure 1-4.
(1) AC power socket (2) Grounding screw
Figure 1-4 Rear panel of the A3600-24TP SI
II. Power system
The following gives the input voltage specifications for the A3600-24TP SI:
Rated voltage range: 100 VAC to 240 VAC, 50/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 to 63 Hz
1.4 A3600-48 SI
1.4.1 Front Panel
I. Schematic diagram
On the front panel, the A3600-48 SI provides forty-eight 10Base-T/100Base-TX auto-sensing Ethernet ports, four 1000Base-X
SFP ports, and one Console port, as shown in Figure 1-5.

(1) 10Base-T/!00Base-TX auto-sensing Ethernet port status LEDs (2) Console port
(3) 7-segment digital LED (4) Mode button
(5) Mode LED (6) AC power LED
(7) 1000Base-X SFP port status LEDs
Figure 1-5 Front panel of the A3600-48 SI
II. LEDs
On the front panel, the A3600-48 SI provides one AC power LED, one mode LED, one 7-segment digital LED, forty-eight
10Base-T/100Base-TX Ethernet port status LEDs, and four 1000Base-X SFP port status LEDs. You can learn how the switch
operates by observing the LEDs listed in Table 1-2.
III. Attributes of 10Base-T/100Base-TX Ethernet ports
Table 1-8 Attributes of the 10Base-T/100Base-TX Ethernet ports on the A3600-48 SI
Attribute Description
Connector RJ-45
Number of ports 48
Rate
10 Mbps, half duplex/full duplex
100 Mbps, half-duplex/full duplex
MDI/MDI-X auto-sensing
Standard IEEE 802.3u
Transmission distance over the selected
medium 100 m (328.08 ft) over the category-5 unshielded twisted pair
(UTP) cable
IV. Console port
The A3600-48 SI provides one EIA/TIA-232 compliant Console port for local or remote switch configuration. For the attributes,
see Table 1-4.
V. Attributes of the 1000Base-X SFP ports
The A3600-48 SI provides four 1000Base-X SFP ports numbered 49 to 52 on the front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.

Note:
The types of 1000Base-X SFP modules may be subject to
changes without notice. Consult HP marketing personnel or
technical support personnel to obtain the latest information
about SFP modules.
For specifications of SFP modules, refer to HP Low End
Series Ethernet Switches Pluggable Modules Manual.
1.4.2 Rear Panel
I. Schematic diagram
The A3600-48 SI provides an AC power socket and a grounding screw on its rear panel, as shown in Figure 1-6.
(1) AC power socket (2) Grounding screw
Figure 1-6 Rear panel of the A3600-48 SI
II. Power system
The following gives the input voltage specifications for the A3600-48 SI:
Rated voltage range: 100 VAC to 240 VAC, 50/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 to 63 Hz
1.5 A3600-24 EI
1.5.1 Front Panel
I. Schematic diagram
On the front panel, the A3600-24 EI provides twenty-four 10Base-T/100Base-TX auto-sensing Ethernet ports, four 1000Base-X
SFP ports, and one Console port, as shown in Figure 1-7.
(1) 10Base-T/100Base-TX auto-sensing Ethernet port status LEDs

(2) 1000Base-X SFP port status LEDs (3) Console port
(4) 7-segment digital LED (5) DC power LED
(6) AC power LED (7) Mode LED
(8) Mode button
Figure 1-7 Front panel of the A3600-24 EI
II. LEDs
On the front panel, the A3600-24 EI provides one AC power LED, one DC power LED, one mode LED, one 7-segment digital
LED, twenty-four 10Base-X/100Base-TX auto-sensing Ethernet port status LEDs, and four 1000Base-X SFP port status LEDs.
You can learn how the switch operates by observing the LEDs listed in Table 1-9.
Table 1-9 LEDs on the front panel of the A3600-24 EI
LED Mark Status Indication
AC power
LED PWR
Solid green The system passes the Power-On Self-
Test (POST) and is operating normally.
Flashing green (1 Hz) The system is running a POST or is
downloading software.
Solid red The POST of the system fails or a serious
fault is detected.
Flashing yellow (1 Hz) Some ports fail to pass the POST and
some functions are disabled.
OFF The power is disconnected.
DC power
LED RPS
Solid green Both the internal AC power supply and the
DC input are normal.
Solid yellow The internal AC power supply fails or is
disconnected, but the DC input is normal.
OFF The DC input is not connected.
Mode LED Mode
Speed Solid green Rate information of the 10Base-T/100Base-
TX Ethernet ports and the 1000Base-X
SFP ports.
Duplex Solid yellow Duplex information of 10Base-T/100Base-
TX Ethernet ports and the 1000Base-X
SFP ports.
7- segment
digital LED Unit
POST
running PWR flashes green
(1 Hz) Displays the POST test ID (in the range of
1 to 9).
POST failed
The PWR LED
flashes yellow. Flashes the POST test ID of the failed test.
The PWR LED is
solid red.
Software
loading The PWR LED
flashes green. A bar rotates clockwise around the LED.
Fan failure The PWR LED is
red Displays “F”.
Unit ID Button released Displays the unit ID in the fabric; and
displays “1” if there is only one unit.
10Base-
T/100Base-
TX Ethernet
port status
— Speed Green ON A 100 Mbps link is present.
Flash Data is being received/sent on the port

LED Mark Status Indication
LED Yellow ON A 10 Mbps link is present.
Flash Data is being received/sent on the port
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode.
Flash Data is being received/sent on the port
Yellow ON The port is operating in half duplex mode.
Flash Data is being received/sent on the port
Flashing yellow (3
Hz) The port fails POST.
OFF No data is being received/sent on the port.
1000Base-X
SFP port
LED —
Speed
Green ON A 1000 Mbps link is present.
Flash Data is being received/sent on the port
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
Duplex
Green ON The port is operating in full duplex mode
Flash Data is being received/sent on the port
Flashing yellow (3
Hz) The port fails POST.
OFF No data is being received/sent on the port.
PoE mode
Flashing green (3
Hz) The port fails POST.
OFF ––
Status LED
of
1000Base-X
SFP port
serving as a
fabric port
—
Speed
Green ON The port is connected, and the device is in
an IRF loop fabric.
Flash Data is being received/sent on the port.
Yellow ON The port is connected and the device is in
an IRF chain fabric.
Flash Data is being received/sent on the port.
Flashing green
(3Hz) A fault occurs to the fabric.
Flashing yellow (3
Hz) The port fails to pass POST.
OFF The port is not connected.
Duplex Green ON The port is operating in full duplex mode.
Flash Data is being received/sent on the port.

LED Mark Status Indication
Flashing yellow (3
Hz) The port fails to pass POST.
OFF The port is not connected.
PoE mode
Flashing yellow (3
Hz) The port fails a POST.
OFF ––
III. Attributes of the 10Base-T/100Base-TX Ethernet ports
See Table 1-3.
IV. Console port
The A3600-24 EI provides one EIA/TIA-232 compliant Console port for local or remote switch configuration. For the attributes,
see Table 1-4.
V. Attributes of the 1000Base-X SFP ports
The A3600-24 EI provides four 1000Base-X SFP ports numbered 25 to 28 on the front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.
Note:
The types of 1000Base-X SFP modules may be subject to
changes without notice. Consult HP marketing personnel or
technical support personnel to obtain the latest information
about SFP modules.
For specifications of SFP modules, refer to HP Low End
Series Ethernet Switches Pluggable Modules Manual.
1.5.2 Rear Panel
I. Schematic diagram
The A3600-24 EI provides an AC power socket, a DC power socket and a grounding screw on the rear panel, as shown in
Figure 1-8.
(1) AC power socket (2) DC power socket (3) Grounding screw
Figure 1-8 Rear panel of the A3600-24 EI
II. Power system
AC power
Rated voltage range: 100 VAC to 240 VAC, 50 Hz/60 Hz
Input voltage range: 90 VAC to 264 VAC, 47 Hz to 63 Hz

DC power
Rated voltage range: –48 VDC to –60 VDC
Input voltage range: –36 VDC to –72 VDC
1.6 A3600-24-SFP EI
1.6.1 Front Panel
I. Schematic diagram
On the front panel, the A3600-24-SFP EI provides twenty-four 100Base-X SFP ports, two 1000Base-X SFP ports, two
10/100/1000Base-T auto-sensing Ethernet ports, and one Console port, as shown in Figure 1-9.
(1) 100Base-X SFP port status LEDs (2) 1000Base-X SFP port status LEDs
(3) 10/100/1000Base-T auto-sensing Ethernet port status LEDs
(4) Console port (5) 7-segment digital LED
(6) DC power LED (7) AC Power LED
(8) Mode LED (9) Mode button
Figure 1-9 Front panel of the A3600-24-SFP EI
II. LEDs
On the front panel, the A3600-24-SFP EI provides one AC power LED, one DC power LED, one mode LED, one 7-segment
digital LED, twenty-four 100Base-X SFP port status LEDs, four 1000Base-X SFP port status LEDs, and two 10/100/1000Base-T
auto-sensing Ethernet port status LEDs. You can learn how the switch operates by observing the LEDs listed in Table 1-10.
Table 1-10 LEDs on the front panel of the A3600-24-SFP EI
LED Mark Color Indicates
AC Power LED PWR
Solid green The system passes the Power-On
Self-Test (POST) and is operating
normally.
Flashing green (1 Hz) The system is going through the
POST or is downloading software.
Solid red The POST of the system fails or a
serious fault is detected.
Flashing yellow (1 Hz) Some ports fail to pass the POST
and some functions are disabled.
OFF The power is disconnected.
Mode LED Mode Speed Solid green Rate information of the 10Base-
T/100Base-TX Ethernet ports and
the 1000Base-X SFP ports.

LED Mark Color Indicates
Duplex Solid yellow Duplex information of 10Base-
T/100Base-TX Ethernet ports and
the 1000Base-X SFP ports.
7- segment digital
LED Unit
POST
running The PWR LED
flashes green. Flashes the POST test ID of the
failed test.
POST failed
The PWR LED
flashes yellow. POST test ID of the failed test.
A bar rotates clockwise around the
LED.
PWR stays red
Software
loading The PWR LED
flashes green. Displays “F”.
Fan failure The PWR LED is
solid red Displays the unit ID in the fabric; and
displays “1” if there is only one unit.
Unit id Button released Flashes the POST test ID of the
failed test.
100Base-X SFP
port status LED —
Speed
Green
ON A 100 Mbps link is present.
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
Duplex
Green
ON The port is operating in full duplex
mode
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF No data is being received/sent on the
port.
1000Base-X SFP
port status LED —
Speed
Green
ON A 1000 Mbps link is present.
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
Duplex
Green
ON The port is operating in full duplex
mode
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF No link is present.
PoE
Flashing green (3
Hz) The port fails POST.
OFF ––

LED Mark Color Indicates
Status LED of
1000Base-X SFP
port serving as a
fabric port —
Speed
Green
ON The port is connected, and the
device is in an IRF loop fabric.
Flash Data is being received/sent on the
port
Yellow
ON The port is connected, and the
device is in an IRF chain fabric.
Flash Data is being received/sent on the
port
Flashing green (3
Hz) A fault occurs to the fabric.
Flashing yellow (3
Hz) The port fails POST.
OFF The port is not connected.
Duplex
Green
ON The port is operating in full duplex
mode
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF The port is not connected.
PoE
OFF No data is being received/sent
Flashing yellow (3
Hz) The port fails POST.
10/100/1000Base-
T port LED —
Speed
Green
ON A 1000 Mbps link is present.
Flash Data is being received/sent on the
port
Yellow
ON A 10/100 Mbps link is present.
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF The port is not connected.
Duplex
Green
ON The port is operating in full duplex
mode
Flash Data is being received/sent on the
port
Yellow
ON The port is operating in half duplex
mode
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF No data is being received/sent on the
port.

LED Mark Color Indicates
10/100/1000Base-
T Fabric port LED —
Speed
Green
ON The port is connected, and the
device is in an IRF loop fabric.
Flash Data is being received/sent on the
port
Yellow
ON The port is connected, and the
device is in an IRF chain fabric.
Flash Data is being received/sent on the
port
Flashing green (3
Hz) A fault occurs to the fabric.
Flashing yellow (3
Hz) The port fails POST.
OFF The port is not connected.
Duplex
Green
ON The port is operating in full duplex
mode
Flash Data is being received/sent on the
port
Flashing yellow (3
Hz) The port fails POST.
OFF The port is not connected.
PoE
OFF No data is being received/sent
Flashing yellow (3
Hz) The port fails POST.
III. Attributes of the 100Base-X SFP ports
The A3600-24-SFP EI provides twenty-four 100Base-X SFP optical ports numbered from 1 to 24 on the front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-11 lists the available 100Base-X SFP modules.
Table 1-11 100Base-X SFP modules
Type Model
100Base-X SFP module
SFP-FE-SX-MM1310-A
SFP-FE-LX-SM1310-A
SFP-FE-LH40-SM1310
SFP-FE-LH80-SM1550
IV. Attributes of the 1000Base-X SFP ports
The A3600-24-SFP EI provides two 1000Base-X SFP ports numbered 25 and 26 on the front panel.
SFP modules allow for great flexibility because they are hot swappable and user configurable.
Table 1-5 lists the available SFP modules.
Table of contents
Other H3C Switch manuals

H3C
H3C S6850-56HF Operating and maintenance manual

H3C
H3C S1850 Series User manual

H3C
H3C S6800-32Q Operating and maintenance manual

H3C
H3C S6520XE-HI Series User manual

H3C
H3C S5820 series Installation manual

H3C
H3C H3C S5100-SI User manual

H3C
H3C SecPath NSQ1FAB12D0 User manual

H3C
H3C S6850 Series User manual

H3C
H3C S7500X Series User manual

H3C
H3C s5800 series User manual

H3C
H3C S9500 Series User manual

H3C
H3C S9500 Series Installation instructions

H3C
H3C S6890 Series Quick guide

H3C
H3C S7500 Series User manual

H3C
H3C S5120-EI Series User manual

H3C
H3C S7500X Series User manual

H3C
H3C S7500 Series User manual

H3C
H3C H3C S5800-32F User manual

H3C
H3C H3C S7500E Series User manual

H3C
H3C S3100V2-52TP User manual