Haier ESA418J User manual

Mode ESA418J
Feature
Top Discharge Airflow Pattern
Ultra-Quiet Operation
Modern Family-look Design
Safety Power Cord
3 Cool Settings, 3 Fan Settings
Easy-to-install Mounting Kit
Easy-Access Washable Filter
Digital Time & Temperature Display
24 Hour on/off Timer
SERVICE MANUAL
Order No.AC0909S001V0
Haier Group
©2009 (Qingdao Haier Air Conditioner General corp.,Ltd)
All right reserved .Unauthorized copying and distribution is a violation of law
This service information is designed for experienced repair technicians only and is not designed for use by the general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attemting to service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or
repair the product or products dealt with in this service information by anyone else could result in serious injury or death
WARNING

Table of Content
ESA418J Table of Contents
Domestic Air Conditioner
1
1. Product Code Illumination and Series introduction......................................
2. Specifications....................................................................................................
3. Safety and Precaution.......................................................................................
4. Warning and Cautions......................................................................................
5. Installation and Accessory Parts.....................................................................
6. Parts and Functions........................................................................................
7. Abnormity Diagnose........................................................................................
8. System Flow Chart...........................................................................................
9. Circuit Diagram................................................................................................
10. Wiring Diagram..............................................................................................
2
3
4
5
7
13
17
20
21
22

1. Product Code Illumination and Series Introduction
2). Standard situation/conditions
Indoor air state outdoor air state
No. Operating condition D.B. ℃ W.B. ℃ D.B. ℃ W.B. ℃
1 Nominal cooling 26.7 19.4 35 23.9
ESA418J Illumination and Introduction
Domestic Air Conditioner
2
1). Model identification:
A: Abbre viation of Energy Star
B: The type of refrigerant
4:R410A
C: Nominal cooling capacity (BTU/h) with the first two numbers based on one thousand unit
D: Desigh code
Examples:
ESA418J
It represents remote control window air condition r. Cooling capacity is 18000/17600BTU/h and the power
supply is 115V/60Hz.
ESA □□ □
AC D
□
B

2. Specification
Item Unit ESA418J
Cooling capacity BTU/h 18000/17800
Heating capacity BTU/h /
Power supply 1PH 230/208V 60HZ
Power input W 1680/1660
Running current A 7.4/8.2
Cooling
EER BTU/(h·W) 10.7/10.7
Power input W /
Running current A /
Heating
COP BTU/(h·W) /
Indoor side dB(A) 57
Sound Level Outdoor side dB(A) 61
Height inches 16 3/4
Width inches 24 3/8
Net dimensions
Depth inches 23 7/16
Height inches
28 3/4
Width inches
20 7/8
Packaging
dimensions Depth inches
27 1/8
Net lbs 114
Weight Gross lbs 129
Type TOSHIBA
Model / PA165M2C-3ETU
Compressor
Running cap. For comp. µF 40/450
Hi-Pressure Psig 570
Pressure Low-Pressure Psig 270
Model R22 or R410A R410A
Refrigerant
Charge OZ 41.6
Indoor unit / centrifugal
Type Outdoor unit / axial
Fan
Fan Speed Indoor unit r/min 1060/990/940
Air volume CFM 420/390/370
Moisture removal Pints/hr 5.3
ESA418J Specification
Domestic Air Conditioner
3

3. Safety and Precaution
WARNING: Following these basic precautions will reduce the risk of fire ,electrical shock ,injury or death
when using your air conditioner .
1) Air conditioner must be connected to proper electrical outlet with the correct electrical supply .
4)DO NOT USE AN ADAPTER OR AN EXTENSION CORD.
5)When installing your air conditioner in a window,make sure the window is strong enough to hold the weight
of the air conditioner.You also want to secure and correctly install your air conditioner property to prevent it
from falling.Extra brackets or support may be required depending on your window.
3) DO not use if power cord is frayed or damage . Also avoid using if there are cracks or abrasion damage
along the length ,plug or connector .
6) Do not black airflow inside or outside the air conditioner with blinds,drapes,protective covers,shrubs or
bushes.
9)Always unplug the air conditioner before servicing it or moving it .
7)Be careful of sharp edges on the front and rear fins of the unit that could cut and cause serious injury.
8)Be careful when lifting the air conditioner to install or remove the unit . Always use two or more people
for this .
2) Proper grounding must be ensured to reduce the risk of shock and fire .
DO NOT CUT OR REMOVE THE GROUNDING PRONG.
If you do not have a three-prong electric receptacle outlet in the wall, have a certified electrician install the
proper receptacle . The wall receptacle MUST be properly grounded .
ESA418J Specification
Domestic Air Conditioner
4

ESA418J Warning and Cautions
Domestic Air Conditioner
5
4.Warning and Cautions
WARNINGS: Following the safety messages is very important .
These
This room air conditioner must be grounded . Grounding reduces the risk of electric shock by
providing an escape wire for the electric current . The power cord has a grounding wire with a
grounding plug . Plug it into an outlet that is properly installed and grounded .
Improper use of the grounding plug can result in a risk of electric shock .
Call a qualified electrician if you don’t understand the grounding instructions or if you are not sure
if the air conditioner is properly grounded .If the wall outlet is not grounded , please contact an
electrician to have it replaced with a properiy grounded outlet .
We strongly advise against using an adapter plug .
messages can save
you
from
being
injured
or
killed. Warning symbols alert you to be
careful and means Danger . Always follow instructions to be safe and reduce chances of injury
or death . Warning and Dangersigns will precde safety messages .
Electrical Safety
Grounding:
WARNING:
Do not, under any circumstances, cut or remove the third (ground) prong from the
power cord.
Adapter Plug:

ESA418J Warning and Cautions
Domestic Air Conditioner
6
Tips
This air conditioner is designed for use in a double hung window .
Only let a certified electrician modify your electrical outlet .
When installing your air conditioner , make sure to seal all areas where there is a possibility of air leakage.
Do not needlessly use electrical light or other appliances that produce heat .
Keep the blinds and drapes drawn on all other windows .
While cooking ,use an exhaust fan in the kitchen to remove the excess heat .
Always use the correct BTU size air conditioner to cool the room to attain optimum efficiency .
The airflow should not be blocked , either inside by curtains , drapes or furniture , or outside by shrubs or
bushes .
Use a dedicated line for the operation of your air conditioner to avoid the possibility of an electrical surge.
The window has to be strong for installation . Extra brackets and/or support may be required depending
on your window .(Brackets and supports not included in all models .)
Install the unit on the north side , as that is normally the shaded side . This will enhance the operation
of your unit .
While installing unit be sure to tilt air conditioner 5 degrees outward to have the water drip outside the
house .
Measure the window before installing . If the window is too big for the unit you may require professional
installation . Use the correct electric voltage and proper ampere for the unit to run effectively .
Energy Saving Guide

5. Installation and Accessory Parts
Check the following before you install your air conditioner:
1) The unit is free of all obstructions inside and outside the room e.g. drapes, curtains, furniture, plants,
shrubs, bushes, trees, other structures like building, garage etc.
Air conditioner must have clear unobstructed airflow through the condenser to remove the heat.
2) The window is strong enough to hold the weight of the air conditioner. Extra brackets or supports may be
needed depending on your windows. Brackets or supports not not provided in all models.
3) The window sill and track are strong enough to hold the weight of the air conditioner.
4) The wall is strong enough to hold the unit. Extra brackets or supports may be needed depending on the
wall. (Brackets or Supports not provided in all models).
5) There is adequate and proper power supply near the air conditioner.
6) DO NOT use adopter plugs.
7) DO NOT use extension cords.
8) DO NOT cut or remove the ground prong.
9) DO NOT modify the plug or the electrical wall outlet in any way. If plug does not fit the electrical outlet
have a certified electrician do the necessary change.
10) NOT connect electrical power to the unit before installation.
11) DO NOT use if power cord is worn out, hayed or damage. Avoid using if here are cracks or abrasion
damage along the length, plug or connection.
12) Be careful of exposed sharp edges of the cabinet and sharp coils (fins) on the back of the unit that could
cut and cause serious injury.
ESA418J Installation and Accessory Parts
Domestic Air Conditioner
7

ESA418J Installation and Accessory Parts
Domestic Air Conditioner
8
A. 28³⁄8” (72.1 cm) minimum
B. 17³⁄8” (44.1 cm) minimum
Window Installation
Window opening measurements:
■ 28 3⁄8 ” minimum to 38” (72.1 cm to 96.5 cm) maximum opening
width.
■ 17 3⁄8 ” (44.1 cm) minimum opening height.
A
B
Unpack unit on the floor next to installationlocation.
1. Remove two front attachment screws.Separate the outer case from the front with a putty knife at the catch points
designated by the arrows.
2. Remove the two screws on top of the outer case.
3. Using the basepan handle, slowly and evenly pull chassis out from outer case.
Prepare unit for installation
Prepare Air Conditioner for Installation
NOTE: Cover putty knife blade with masking tape to guard against damage of the unit finish.
CAUTION:
Never expose plastic front or grille to extreme temperatures.
NOTE: Attach curtains to the air conditioner before placing the air conditioner in window.
1. Install top channel with four 13/32” screws.
2. Slide left-hand curtain assembly into left end of top and bottom channels. Repeat for right-hand curtain assembly.
3. Fasten curtain retainer strips to the sides of the outer case with eight 13/32” screws.
Assemble Curtain/Top channel

ESA418J Installation and Accessory Parts
Domestic Air Conditioner
9
AB
C
D
A. Top channel
B. 13/32” screws C. 13/32” screws
D. Side curtains
B
A
Prepare Window for Installation
1. Measure the width of the window opening.
2. Mark the center line on the inside windowsill.
A. Width of window opening
B. Center line
NOTES:
Handle the air conditioner gently.
Be sure your air conditioner does not fall out of the opening during installation or removal.
The place where the power cord exits the air conditioner should be no more than 4 ft (122 cm) from a grounded
outlet.
Do not block the louvers in the front panel.
Do not block the louvers on the outside of the air conditioner.
Position Air Conditioner

ESA418J Installation and Accessory Parts
Domestic Air Conditioner
10
A
B
C
NOTE: Your model may differ from the one shown.
A. Side curtain against window channel
B. Window sash behind top channel
C. Bottom channel in behind windowsill
3. Expand both curtains to contact the window frame. Install four wood screws 31/32”. Two in each upper right
and left of the curtains.
4. Use three wood screws 31/32” to fix the case to windows sash.
A. Top channel
B. Window sash
C. Bottom channel
1. Place outer case in window. Lower sash until it rests behind front flange of top channel. Bottom channel must
rest behind window sill.
Install outer case in window
A
C
B

ESA418J Installation and Accessory Parts
Domestic Air Conditioner
11
A
B
Complete Installation
1. Insert the foam seal behind the top of the lower window sash and against the glass of the upper window.
A. Top of lower window sash
B. Foam seal
2. Place the window lock bracket as shown. Use a 1⁄8 ” drill bit to drill a starter hole through the hole in the window
lock bracket and into the upper window.
3. Attach the window lock bracket to the upper window with one 31⁄32” screw to secure the window in place.
4. Plug into a grounded 3 prong outlet.
5. Press RESET on the power supply cord. See “Electrical Requirements.”
Return chassis to the outer case
Find someone to help you replace the chassis in outer case.
Replace front panel and grille.
CAUTION: For security purposes, reinstall screws at cabinet’s sides, removed in step one.
IMPORTANT: Because the window sash helps keep the unit in window, make certain the window sash contacts the
outer case

ESA418J Installation and Accessory Parts
Domestic Air Conditioner
12
Phillips screwdriver
Parts
Tools
A
B
CD
EF
GH
I
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
J
A. Top channel
B. Foam seal
C. Installation brackets
(left and right)
D. Window lock bracket
E. 13⁄32 ” screws (12)
F. 13⁄32 ” bracket screws (6)
G. 31⁄32 ” screws (8)
H. 1/2” Long flat head
bolt and locknut(2)
I. Left and right side
curtains
J. Remote control
Flat-blade screwdriver
Scissors
Level
Socket wrench and sockets
Tape measure
Cordless drill and 1⁄8” bit
Pencil
Pliers
Adjustable wrench
Gather the required tools and parts before starting installation. Read and follow the
instructions provided with any tools listed here.

6. Parts and Functions
ESA418J Parts and Functions
Domestic Air Conditioner
13
1. Press MODE until you see the indicator light glow for the desired setting.
2. Choose Fan, Cool, Energy Saver or Dehum.
■ Fan—Only the fan runs. Press SPEED to select High, Med or Low fan speed. The display shows the current
room temperature.
■ Cool—Cools the room. Press SPEED to select High, Med or Low fan speed. Press the TEMP/TIME up or down
arrow button to adjust the temperature.
Mode
■ Energy Saver—Fan runs only when cooling is needed. Press SPEED to select High, Med or Low fan speed.
Because the fan does not circulate the room air continuously,less energy is used, but the room air is not
circulated as often.
■ Dehum—Dries the room. The air conditioner automatically selects the temperature. Fan runs on Low speed only.
NOTE: Dehum mode should not be used to cool the room.
FAN
COOL
ENERGY
SAVER
DEHUM
MODE
NOTE: After 5 seconds, display will show the current room temperature.
NOTE: In Dehum mode, the Speed button will not operate.
1. Press FAN SPEED until you see the indicator light glow for the desired setting.
2. Choose High, Med or Low.
■ High—for maximum cooling
■ Med—for normal cooling
■ Low—for minimum cooling
NOTE: After 5 seconds, the display will show the current room temperature.
HIGH
MED
LOW
SPEED
Fan Speed
(1) Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME
up arrow button, the temperature will go up 1ºF until it reaches 86°F (30°C).
NOTE: After 5 seconds, the display will show the current room temperature.
TEMP / TIME
Temperature

ESA418J Parts and Functions
Domestic Air Conditioner
14
(2) Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME
down arrow button, the temperature will go down 1ºF until it reaches 61°F (16°C).
NOTE: After 5 seconds, the display will show the current room temperature.
To set the Timer for a 1-hour to 24-hour delay until the air conditioner turns off (the air conditioner must be On):
1. Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner
will turn off.
2. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
3. After 5 seconds, Timer On indicator light will remain on.Display will show the current room temperature.
To set the Timer to turn on the air conditioner, keeping previous settings:
1. Turn on the air conditioner.
2. Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner
will turn on.
3. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
4. After 5 seconds, Timer On indicator light will remain on.Display will show the current room temperature.
ON
OFF
TIMER
Timer Delay
To set the Timer to turn on the air conditioner, changing the previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.
NOTE: In Dehum mode, the Speed button will not operate.
4. Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC).
NOTE: In Fan mode, the temperature cannot be set.
5. Wait 3 seconds before turning off the air conditioner.
6. Press TIMER. Timer On indicator light will flash. Display will show remaining hours before the air conditioner
will turn on.
7. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
8. After 5 seconds, Timer On indicator light will remain on.Display will show the current room temperature.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display will show remaining time.
2. While the display is showing the remaining time, press TIMER again. Timer Off indicator light will turn on.
To see or change the remaining time (in hours):
1. Press TIMER once after it has been programmed. Display will show remaining time.
2. While the display is showing the remaining time, press the up or down TEMP/TIME button to increase or
decrease the time.
3. After 5 seconds, the display will show the current room temperature.

ESA418J Parts and Functions
Domestic Air Conditioner
15
ON/OFF
MODE
SPEED
TIMER
TEMP/TIME
TEMP/TIME
ON/OFF
TEMP/TIME
TEMP/TIME
MODE
SPEED
NOTE:Remote control may differ in appearance.
NOTE: One CR2025 battery (included) powers the remote control. Replace battery after 6 months of use, or when
the remote control starts to lose power.
Press ON/OFF to turn on the air conditioner.
Press MODE to choose Fan, Cool, Energy Saver or Dehum.
Press SPEED to choose High, Med or Low.
Power
Temperature
(1) Press the TEMP/TIME up arrow button to raise the temperature. Each time you press or hold the TEMP/TIME
up arrow button, the temperature will go up 2ºF (1ºC) until it reaches 86°F (30°C).
(2) Press the TEMP/TIME down arrow button to lower the temperature. Each time you press or hold the TEMP/TIME
down arrow button, the temperature will go down 2ºF (1ºC) until it reaches 61°F (16°C).
Mode
Speed
Using the Remote Cotrol

ESA418J Parts and Functions
Domestic Air Conditioner
16
To set the Timer for a Z to 24-hour delay before the air conditioner is turned off (the air conditioner must be On):
1.Press TIMER. Timer On indicator light on the air conditioner control panel will flash.
2. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
3. After 5 seconds,Timer On indicator light on the air conditioner control panel will remain on.
To set Timer to turn on the air conditioner , keeping previous settings:
1. Turn on the air conditioner.
2. Press TIMER. Timer On indicator light on the air conditioner control panel will flash.
3. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
4. After 5 seconds, Timer On indicator light on the air conditioner control panel will remain on.
To set Timer to turn on the air conditioner , changing the
previous settings:
1. Turn on the air conditioner.
2. Adjust the mode to Fan, Cool, Energy Saver or Dehum.
3. For Fan, Cool or Energy Saver mode, adjust the fan speed to High, Med or Low.
NOTE: In Dehum mode, the Speed button will not operate.
TIMER
Timer
4. Adjust the temperature between 61ºF and 86ºF (16ºC and 30ºC).
NOTE:In Fan mode, the temperature cannot be set.
5. Wait 3 seconds before turning off the air conditioner.
6. Press TIMER. Timer On indicator light on the air conditioner control panel will flash. Display will show remaining
hours before the air conditioner will turn on.
7. Press the TEMP/TIME up or down arrow button to change the delay time from 1 hour to 24 hours.
8. After 5 seconds, Timer On indicator light on the air conditioner control panel will remain on. Display will show
the current room temperature.
To clear Timer delay program:
NOTE: Air conditioner can be either on or off.
1. Press TIMER once after it has been programmed. Display on the air conditioner control panel will show
remaining time.
2. While the display is showing the remaining time, press TIMER again. Timer Off indicator light will turn on.
To see or change the remaining time (in hours):
1. Press TIMER once after it has been programmed. Display on the air conditioner control panel will show
remaining time.
2. While the display is showing the remaining time, press the TEMP/TIME up or down arrow button to increase
or decrease the time.
3. After 5 seconds, the display on the air conditioner control panel will show the current room temperature.

If air conditioner does not operate:
Check if unit is plugged in. The plug may have come loose.
Check if the unit is in the "Off" mode.
Air from air conditioner is warm:
The A/C setting may need to be raised.
Ice formation on cooling coils:
The outside temperature is too cold. Set t he unit on "fan only" setting to defrost ice.
The temperature setting may be too cold.
The unit BTU may be too high for the room.
Air conditioner is working but room is not cooling:
The room may have appliances that produce heat. Use an exhaust fan to remove excess heat.
Redirect the airflow. Remove any obstacles.
All doors and windows need to be closed so cool air does not escape the room.
The air filter may need cleaning.
The unit BTU may be too low fo r the required cooling area.
On extreme hot & humid days, air conditi oners may take a little longer to cool.
Vent may be in the open position. Vent has to be closed for optimum cooling.
Air conditioner is making noise when cooling:
You may hear sounds of air movement, water, co mpressor clicking on and off or window vibrations.
Please read Operating Guide - Normal Operating Sounds.
Water in the air conditioner cabinet:
This is normal, as your air condi tioner not only cools but also dehumidifies the air. If there is water
dripping inside the room, check the installation of the unit. The unit may need to be reinstalled.
ESA418J Abnormity Diagnose
Domestic Air Conditioner
17
7. Abnormity Diagnose

Trouble shooting:
Indoor Possible Reasons
E0 1) Room-temperature sensor is broken.
2) Indoor PCB is damaged.
E1 1) Connection is bad.
2) Indoor PCB is damaged.
E0: Room temperature sensor malfunction
Firstly check whether
Terminal CN2 on the
mainboard contact well
or not?
Pull out the terminals on
the mainboard and
reinsert them.
Pull the sensor out of the mainboard
1) Measure the value of resistance
between its two jumpers
2) Measure the temperature at the room
temperature sensing head.
Check the specifications of the sensor
to decide whether the sensor is
damaged or not?
Replace with new
sensor.
The PCB is broken.
Replace with new PCB
No
Yes
Yes
No
ESA418J Abnormity Diagnose
Domestic Air Conditioner
18

E1: Bottom malfunctions
Repair the plastic keystrokes of the
electric box to keep them away from
the keystroke of mainboard.
Replace the indoor
PCB with new one.
Yes
No
Check whether the keystroke
can't work due to extrusion.
ESA418J Abnormity Diagnose
Domestic Air Conditioner
19
Table of contents
Other Haier Air Conditioner manuals

Haier
Haier HSU-09RQ03-R2 User manual

Haier
Haier HW-12C03 User manual

Haier
Haier AF092XCERA User manual

Haier
Haier HSU22VCA User manual

Haier
Haier HSU-16HZ03 User manual

Haier
Haier AU78NMTAAA User manual

Haier
Haier HSU12 User manual

Haier
Haier HPU-18H03 User manual

Haier
Haier AU242FHBHA User manual

Haier
Haier HSU-09XC7 User manual

Haier
Haier HSU09XC7 HSU09XC7-G User manual

Haier
Haier HSU18VH7 User manual

Haier
Haier ESA415J User manual

Haier
Haier QHEK08AC User manual

Haier
Haier HSU-12RM03 User manual

Haier
Haier HWS24VHA User manual

Haier
Haier AB142ACNBC User manual

Haier
Haier HSU-09LEB13-H - annexe 1 User manual

Haier
Haier AD182AMEAA Instruction Manual

Haier
Haier SUPER MATCH AS50S2SF1FA-CW User manual