manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Haier
  6. •
  7. Air Conditioner
  8. •
  9. Haier HSU-12LEA13-M User manual

Haier HSU-12LEA13-M User manual

No.0010515136
Installation Manual of Room Air Conditioner
Read this manual before installation
1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)
5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife
9.Nipper 12.Reamer
10.Gas leakage detector or
soap-and-water solution
11.Measuring tape
Explain sufficiently the operating means to the user
according to this manual.
A
B
C
D
E
F
G
Optional parts for piping
Mark Parts name
Non-adhesive tape
Adhesive tape
Saddle(L.S) with screws
Connecting electric cable
for indoor and outdoor
Drain hose
Heating insulating material
Piping hole cover
Arrangement of piping directions
Rear left
Rear
right
Left
Below
Right
The marks from to in the figure are the parts numbers.
The distance between the indoor unit and the floor should be
more than 2m.
AG
Attention must be paid to
the rising up of drain hose
more than 5cm
more than 10cm
more than 10cm
A
C
No. Accessory parts
Remote controller
R-03 dry battery
Mounting plate
Drain hose
Steel nail, cement
Screw Plastic cap
Cover
Cushion
1
1
2
3
4
5
6
7
8
9
2
1
1
6
4
1
4
1
Number
of
articles
Accessory parts
4X50
4X25
Pipe supporting plate
more than 10cm
more than 60cm
more than 15cm
more than 10cm
D
E
Drawing for the installation of indoor and outdoor units
Necessary Tools for Installation
Selection of pipe
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
2
1.Fitting of the Mounting Plate and Positioning of the wall Hole
2.Making a Hole on the Wall and Fitting the Piping Hole Cover
When the mounting plate is first fixed
1.Carry out, based on the neighboring pillars or lintels, a proper leveling for the plate to be
fixed against the wall, then temporarily fasten the plate with one steel nail.
2. Make sure once more the proper level of the plate, by hanging a thread with a weight from
the central top of the plate, then fasten securely the plate with the attachment steel nail.
3. Find the wall hole location A using a measuring tape
Make a hole of 60 mm in diameter,
slightly descending to outside the wall.
Install piping hole cover and seal it
off with putty after installation
(Section of wall hole) Piping hole pipe
Outdoor side
Thickness
of wall
Indoor side
Wall hole
60mm
G
Indoor unit
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
140 500 140
652
113.5
583
113.5
5
.
9
1
3
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
140 140415
0
82
For 22k,24k
15.88mm(5/8")
9.52mm(3/8")
Liquid pipe ( )
For 5k,7k,9k,10k
6.35mm(1/4")
Gas pipe ( ) 9.52mm(3/8")
For 12k,13k,18k
6.35mm(1/4")
12.7mm(1/2")
A=145mm
B= 60mm
30mm
HSU-22HEA03
HSU-24HEA03
HSU-18CRA03-T
HSU-12LEA03
HSU-18LEA03
HSU-18LEA13-W
HSU-10LEA03-T
HSU-13LEA03-T
HSU-09LEB13-H
HSU-09LEA13-H
HSU-12LEA13-H
HSU-14LEA13-H
HSU-12LEB13-H
HSU-14LEB13-H
HSU-18LEA13-H
HSU-12CRA03-T
HSU-18CRA03-T
HSU-18HEA13(T3)
HSU-18HEA03(T3)
AMS12H03-N
AMS18H03-N
PAS18L03-N(T3)
HSU-12LEA13-M
HSU-18LEA13-M
HSU-18LEA03(T3)
HSU-18LEA13(T3)
HSU-12LEA13-F
HSU-09HEA03/(DB)
HSU-09HEA03/(BP)
HSU-12HEA03/(DB)
HSU-12HEA03/(BP)
HSU-12HEA03
HSU-18HEA03
HSU-22LEA03
HSU-24LEA03
HSU-22LEA13-W
HSU-18LEA03-T
AMS22H03-N
HSU-05LEA03
HSU-07LEA03
HSU-09LEA03
HSU-09LEA13-W
HSU-12LEA13-W
HSU-09LEA13-F
HSU-09HEA03
HSU-07HEA03
HSU-12HEB03
HSU-09CRA03-T
AMS09H03-N
YKS-09HEA03 YKS-12HEA03
YKS-18HEA03
YKS-22HEA03
A=145mm
B= 60mm
30mm
HSU-12LEA03
HSU-10LEA03-T
HSU-09LEB13-H
HSU-09LEA13-H
HSU-12LEA13-M
HSU-12LEA13-F
HSU-12HEA03
HSU-05LEA03
HSU-07LEA03
HSU-09LEA03
HSU-09LEA13-W
HSU-12LEA13-W
HSU-09LEA13-F
HSU-09HEA03
-mod 22 24: 4G0.75mm
connecting wiring:
-mod 05-13: 3G1.0mm
-mod 18: 3G2.0mm
-mod 22 24 :3G2.5mm
Power cable:
-mod 05-13: 3G1.0mm
-mod 18: 3G1.5mm
Indoor unit
1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similar qualified person.The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.
3
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side.
Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.
Pull the cable slightly to make sure the cables have been properly inserted and tightened.
After the cable connection, never fail to fasten the connected cable with the wiring cover.
Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully.
If wiring
is not correct, proper operation can not be carried out and will cause defect.
5. A breaker should be incorporated into fixed wiring. The breaker should be all-pole switch and the
distance between its two contacts should be not less than 3mm.
Connecting the indoor/outdoor Electric Cable
Removing the wiring cover
Remove terminal cover at right bottom corner of indoor unit, then
take off wiring cover by removing its screws.
When connecting the cable after installing the indoor unit
1. Insert from outside the room cable into left side of the wall hole, in which
the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable making a loop.
HSU-22LEA13-W
: 3G2.0mm
HSU-05LEA03
HSU-07LEA03
HSU-09LEA03
Indoor unit Outdoor unit
HSU-12LEA03
HSU-18LEA03
Indoor unit Outdoor unit
12
N
L
HSU-22LEA03
HSU-24LEA03
Indoor unit
Outdoor unit
power plug
)L
(
134
)N(2
)
L
(1 )
N(
2
)L
(
13 4)N(2
)
L
(
13 4)
N
(
2
{
HSU-09LEA13-W
HSU-18LEA13-W
HSU-22LEA13-W
HSU-10LEA03-T
HSU-13LEA03-T
HSU-09LEB13-H
HSU-12LEB13-H
HSU-14LEB13-H
HSU-09LEA13-H
HSU-12LEA13-H
HSU-14LEA13-H
HSU-18LEA13-H
HSU-18LEA03-T
HSU-09LEA13-F
HSU-12LEA13-M
HSU-18LEA13-M
HSU-18LEA03(T3)
HSU-18LEA13(T3)
HSU-12LEA13-F
HSU-12LEA13-W
HSU-09HEA03/(DB)
HSU-09HEA03/(BP)
1(N) 2(L)3(C)
3(C)
2(L)
1(N)
HSU-12HEA03/(DB)
HSU-12HEA03/(BP)
Indoor unit Outdoor unit
connecting wiring:
Power cable: -mod 09-12:
3G1.0mm
-mod 09-12:
3G1.5mm +1X0.75mm
HSU-18HEA03
HSU-12HEA03
6G0.75mm
Power cable:
3G2.5mm
3G2.5mm
Indoor unit
45
3
2
1L
N
POWER
Outdoor unit
HSU-22HEA03
HSU-24HEA03
3X1.0mm
HSU-09HEA03 HSU-12HEB03
HSU-07HEA03
Indoor unit Outdoor unit
2X0.75mm
3X1.0mm
Indoor unit Outdoor unit
2X0.75mm
Power cable:
3G1.0mm
Power cable:
HSU-09CRA03-T
HSU-12CRA03-T
Indoor unit Outdoor unit
1(L)3 42(N)
Power cable:
-mod 12: 3G1.0mm
HSU-18CRA03-T
3G2.5mm
-mod 18: 3G2.5mm
HSU-18HEA13(T3)
HSU-18HEA03(T3)
AMS09H03-N
AMS12H03-N
AMS18H03-N
AMS22H03-N
PAS18L03-N(T3)
3X2.5mm
Indoor unit Outdoor unit
2X0.75mm
Power cable:
3G2.5mm
If the fuse of outdoor unit on PC board is broken, please change it with the type of T. 25A/250V.
YKS-09HEA03
YKS-12HEA03
YKS-18HEA03
YKS-22HEA03
Outdoor unit
1.Connection of pipes
2.Attaching Drain-Elbow
To bend a pipe, give the roundness as large as possible not to crush the pipe
Connecting the pipe of gas side first makes working easier.
The max vertical distance between the indoor unit and the outdoor unit is 5 m.
If the drain-elbow is used, please attach it as
figure. (Note: Only for heat pump unit.)
Half union Flare nut
Spanner
Torque wrench
4
Outdoor unit
Forced fastening without careful centering
may damage the threads and cause a
leakage of gas.
Be careful that matters, such as wastes of sands, etc.
shall not enter the pipe.
3.Purging Method:
Push the air out of the indoor unit and piping as followes:
Tighten the caps on the valves with specified torque.
Valve rod
Valve cap
7-9
20-25
Tighten torque N.m
When connecting pipe exceeds 5 meters, 20g or 60g(only for 22k 24k) refrigerant shall be
added per exceeding meter. Charge according to the following list.
Piping length
Additional amount
5m 7m
No need 40g
10m
100g
for 5k 7k 9k 10k 12k 13k 18k
for 22k 24k
Max. Length: for 5K 7K 9K 10K: A=7m
for 12K 13K: A=10m
for 18K 22K 24K: A=20m
Max.Elevation:
for 5K 7K 9K 10K 12K 13K: B=5m
for 18K 22K 24K: B=10m
Piping length
Additional amount
5m 7m
No need 120g
10m
300g
20m
900g
Outdoor unit
Indoor unit
A
B
Outdoor unit
Indoor unit
B
A
C
Outdoor unit
Indoor unit
Oil trap
A
B
CAUTION
In case more than 5 metres,oil trap
should be installed every 5~7m.
C
Pipe Diameter ( )
Liquid side 6.35mm(1/4")
Gas side 9.52mm(3/8")
Fastening torque
18N.m
40N.m
Gas side 12.7mm(1/2") 50N.m
Gas side 15.88mm(5/8") 60N.m
Liquid side 9.52mm(3/8") 40N.m

Other manuals for HSU-12LEA13-M

2

This manual suits for next models

50

Other Haier Air Conditioner manuals

Haier ESA3067 - annexe 1 User manual

Haier

Haier ESA3067 - annexe 1 User manual

Haier Room Air Conditioners User manual

Haier

Haier Room Air Conditioners User manual

Haier HC18-60A1VAR/S User manual

Haier

Haier HC18-60A1VAR/S User manual

Haier AC092ACBHA User manual

Haier

Haier AC092ACBHA User manual

Haier AB142ACNBC User manual

Haier

Haier AB142ACNBC User manual

Haier GE NS23AM User manual

Haier

Haier GE NS23AM User manual

Haier HSU-09HSA103-R2 User manual

Haier

Haier HSU-09HSA103-R2 User manual

Haier HBU-42CH03 User manual

Haier

Haier HBU-42CH03 User manual

Haier HSU-24LEA03-T User manual

Haier

Haier HSU-24LEA03-T User manual

Haier AP422ACEAA User manual

Haier

Haier AP422ACEAA User manual

Haier AD242ALEAA Installation and operating instructions

Haier

Haier AD242ALEAA Installation and operating instructions

Haier AE072FEAHA User manual

Haier

Haier AE072FEAHA User manual

Haier HSU-14HR03/R2 Instruction manual

Haier

Haier HSU-14HR03/R2 Instruction manual

Haier HSU-05LE03 User manual

Haier

Haier HSU-05LE03 User manual

Haier HSU-12HJ03/R2 User manual

Haier

Haier HSU-12HJ03/R2 User manual

Haier AS072AZADA User manual

Haier

Haier AS072AZADA User manual

Haier HSU-24HEA03(T3) User manual

Haier

Haier HSU-24HEA03(T3) User manual

Haier HSU-09LC03 User manual

Haier

Haier HSU-09LC03 User manual

Haier HSU-12RUE03 User manual

Haier

Haier HSU-12RUE03 User manual

Haier HSU-09CB13 User manual

Haier

Haier HSU-09CB13 User manual

Haier H2SM- - annexe 12 User manual

Haier

Haier H2SM- - annexe 12 User manual

Haier HWS18VCA User manual

Haier

Haier HWS18VCA User manual

Haier HWS12VH6 User manual

Haier

Haier HWS12VH6 User manual

Haier Platinum Series User manual

Haier

Haier Platinum Series User manual

Popular Air Conditioner manuals by other brands

Maplin A75TB user manual

Maplin

Maplin A75TB user manual

S2P KS2P-18C210 owner's manual

S2P

S2P KS2P-18C210 owner's manual

Frigidaire FAZ12ES2A installation instructions

Frigidaire

Frigidaire FAZ12ES2A installation instructions

Friedrich WallMaster WS10 Installation and operation manual

Friedrich

Friedrich WallMaster WS10 Installation and operation manual

Hitachi RAK-18QXD Service manual

Hitachi

Hitachi RAK-18QXD Service manual

Seifert 87622082USL user manual

Seifert

Seifert 87622082USL user manual

air choice TY-EA-03 user manual

air choice

air choice TY-EA-03 user manual

LG LP-F8081CL Service manual

LG

LG LP-F8081CL Service manual

LG LMU365HV Specifications

LG

LG LMU365HV Specifications

Samsung AR18NSWSPWKXCV Service manual

Samsung

Samsung AR18NSWSPWKXCV Service manual

Daikin GTKY50UV16V2 Operation manual

Daikin

Daikin GTKY50UV16V2 Operation manual

Gree GSW12-22L/B Technical & service manual

Gree

Gree GSW12-22L/B Technical & service manual

Samsung AW05F05EA Owner's instructions

Samsung

Samsung AW05F05EA Owner's instructions

Hitachi RAS-70YHA3 instruction manual

Hitachi

Hitachi RAS-70YHA3 instruction manual

Airwell AWSI-HDD018-H11 Service manual

Airwell

Airwell AWSI-HDD018-H11 Service manual

Dimplex DCES09 manual

Dimplex

Dimplex DCES09 manual

LG LMU180CE owner's manual

LG

LG LMU180CE owner's manual

Airwell YCV Series Service manual

Airwell

Airwell YCV Series Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.