0907S005V0
has formed on part of the evaporator or there is no frost attached to it.
d) Pay attention to the speed of temperature drop inside freezer compartment .It is abnormal if the
speed of temperature drop is obviously slower than the corresponding normal speed.
e) Check the environment to see whether it is suitable for placing a refrigerator.
f) Check refrigerator door seal, case, table surface and heat insulation layer.
g) Look at the main control board to ascertain if various indication states are normal.
2) Listen
a) Listen to the noises produced when the compressor is running Hums from a fully enclosed
aggregate unit is the sound caused by overload indicating that the motor cannot be started
normally ,meanwhile ,a clattering sound can be heard from inside the start relay ,which is produced
because the start contacts cannot be released normally .A whistling sound is caused by the high
pressure gas flowing out of the crack of the pressure tube inside the compressor ,and clucks are the
sound of striking after the suspended spring inside the compressor has broken . During the normal
operation of compressor ,a slight and uniform hum sound due to undulation of electric current can be
heard generally ,this is a normal phenomenon .However ,if it sounds like “tong ,tong …”,i.e., an impact
sound inside the compressor ,this means that a large quantity of wet vapour of refrigerant or
refrigerating oil has come into the compressor cylinder ;if it sounds like “dang ,dang…”, a striking
sound of metal parts inside the compressor ,this means that some moving parts have loosened (note
to differentiate this sound from those formed during starting or stopping the compressor).
b) Listen to the sound caused by the flowing of gas in the evaporator Open the refrigerator door while
the compressor is in operation ,incline your ear and listen attentively the gas flow sound inside the
evaporator .If it sounds like gentle whistling accompanied by a sound similar to water flowing ,this is
the sound produced by the normal circulation of refrigerant within the evaporator .In case only the gas
flowing sound can be heard and there is no water flowing sound ,this indicates that the refrigerant has
already percolated .If neither the flowing sound nor the gas sounds from the evaporator can be
heard ,this means that the filter or capillary has been clogged .
3) Touch and Feel
a) Feel the compressor when running, its temperature should be generally less than 90℃in the
normal state (it may exceed 90℃in case of running for a longer period of time ).
b) After the compressor has operated normally for 5~10 minutes, ouch and feel the condenser, the