Halosil HaloFogger STD 1911 User manual

READ AND SAVE THESE INSTRUCTIONS
Operation Manual
110V | 220V
STD
1911
®

High Precision Nozzle
Dry-mist of disinfectant is
dispensed through nozzle.
Digital TImer
Enter minutes to set time for
fogging treatment.
Disinfectant Fluid Level Indicator
Shows how much disinfectant is in the
reservoir and when it is time to rell.
Reservoir Door
Push and lift open to expose
funnel port for relling.
Front Handle
Rear Handle
Start Button
Press and hold for 2 seconds to
begin unit’s countdown and the
treatment process.
Reservoir Door
Funnel Port
Status Indicator Light
Walk Around Tour of the HaloFogger®
Status Indicator Light - Displays the operational status of the Halo device.
Solid Green: Indicates the Halo
is plugged in and ready for use
Flashing Green: Indicates the Reservoir
Door is not closed correctly or an error
has occured. (Refer to Troubleshooting
section of this manual)
Flashing Red: Indicates 30
second countdown after
pressing the Start Button
Solid Red: Indicates the device is
on and dispensing disinfectant.
The room should be unoccupied.
Large Wheels
For easy maneuvering.
Power Cord Connection
Reservoir Drain

Caution
A caution statement in this manual identies a condition or practice which, if not corrected or
discontinued immediately, could lead to serious injury or death.
1. KEEP OUT OF REACH OF CHILDREN.
2. Carefully read all instructions, warnings, cautions and rst aid statements prior to use.
3. Do not enter room while HaloFogger® is in use. Stay out of the room after treatment until room re-entry
wait time has expired. Keep door and windows closed.
4. Use only as directed.
5. Allow the full post-treatment wait time before re-occupying the room. Re-entry before the wait time has
expired could result in sensory irritation and should only be done while using proper personal protection
equipment (PPE) including wrap-around style goggles, 3M respirator mask and gloves.
6. Avoid inhalation of vapors or skin and eye contact with Halo Disinfectant fog.
7. The HaloFogger is designed for ease-of-use. However, only properly trained individuals should use
this device.
8. Electric shock hazard. Do not plug in if electrical plug or parts are wet.
9. There are no user-serviceable parts inside the Halo other than the nozzle. An operator may only perform
maintenance procedures specically described in this manual. The manufacturer should make all
other repairs.
10. While in use, the body of the HaloFogger may become warm to the touch. Use caution when handling.
11. Use personal protection equipment (PPE) including wrap-around style goggles and gloves when pouring
disinfectant uid into the device. Avoid splashing or overlling which could harm the user and/or the device.
12. Halosil International is not responsible for any injury or damage caused by using this device outside of
the specic parameters detailed in this manual.
Operation Warnings
These warnings pertain to the actual use of the HaloFogger® unit.
1. To ensure eectiveness and safety, use only with HaloMist™ All-Purpose Disinfectant. Using any other
manufacturers’ disinfecting or cleaning product will result in serious injury, exposure and
environmental damage.
2. Position the device on a secure surface to prevent rolling or moving while in use.
3. Use only a manufacturer supplied electrical cord.
4. Always unplug the power cord from the outlet before moving the device.
5. Clean debris from the device nozzle and funnel on a regular basis according to the instructions in this
manual (see Maintenance).
6. Regularly check disinfectant uid level to ensure sucient volume is present to treat each particular
room size.
7. Do not set the timer for longer than the suggested fogging time. Excessive fogging can create
condensation, which may activate re alarm systems.
8. Protect this device from severe impact or shock.
9. Take care to prevent water or other uid from entering the device. Should this occur, allow to completely
dry before use. Check the accuracy of all operating functions.
10. Do not tip the HaloFogger on its side at any time unless completely empty and dry.
11. Store HaloFogger in an upright position, in a safe, dry location. Do not place anything on top of
the device.
HaloFogger® Operation Manual_1911

Getting Started with the HaloFogger®
IMPORTANT
Before using your HaloFogger, it is important that you:
1. Plug the HaloFogger into a power source for 24 hours to fully charge the HaloLog’™
Data Logger’s internal back-up battery.
2. Download the HaloMist™ All-Purpose Disinfectant Use Instructions.
Go to www.halosil.com, register your new fogger purchase to download.
Setup and Filling
THE HALOFOGGER IS DESIGNED FOR USE WITH HALOMIST™ ALL-PURPOSE DISINFECTANT AND SHOULD NOT
BE OPERATED WITH ANY OTHER MANUFACTURERS DISINFECTING OR CLEANING PRODUCT.
Setup Instructions
Locate the connector end of the power cord. Insert the connector into the power receptacle located at
the bottom of the rear panel of the HaloFogger. Ensure that the connector is securely in place. Plug the
HaloFogger into a standard electrical outlet. The green status indicator light will illuminate.
Filling Instructions
1. Open the HaloFogger Reservoir Door by lifting front edge of door.
2. Locate the disinfectant uid level indicator lights to the left of the funnel. One ashing red light will be
illuminated indicating the HaloFogger is empty.
3. Use personal protection equipment (PPE) including wrap-around style goggles and gloves when pouring
disinfectant uid into the device.
4. Open a gallon (3.8 liters) bottle of HaloMist™ Disinfectant and SLOWLY pour the contents into the funnel
area. AVOID SPLASHING.
5. The uid level indicator lights will illuminate as you pour to show how much disinfectant is in the device.
6. The HaloFogger holds two gallons (7.6 liters) of disinfectant when full. Stop pouring when the top green
light on the uid level indicator is illuminated. Do not overll.
7. Wipe up any spills with a clean paper towel or rag. Thoroughly rinse o gloves and hands.
8. Close Reservoir Door.
9. The HaloFogger is now ready to be used.
Basic Operating Instructions
1. Set the timer to the number of minutes specied for your room size. See Quick Instructions on rear
of unit.
2. Plug the HaloFogger into a standard, grounded electrical wall outlet. When the power connection has
been made, the green status indicator light on top of the device will illuminate.
3. Check uid level indicator lights. It is recommended the unit’s reservoir be topped o before starting the
treatment process. Refer to “Getting Started with the HaloFogger” above to add/rell disinfectant.
4. Press and hold the Start button for two (2) seconds. The green status light will begin to ash red indicating
you have thirty (30) seconds to leave the room before the unit begins to dispense disinfectant.
5. Leave room, close and seal door. Post sign on door indicating the room should not be entered during the
treatment process.
HaloFogger® Operation Manual_1911

Determining Room Re-Entry Time
Whenever possible, delay re-entry and allow treated room to remain unoccupied overnight. Otherwise,
select the appropriate room re-entry time directive for your facility:
A. If you have no handheld H2O2 sensor but a written protocol has been established by your organization
or an authorized Halosil Distributor for the room or for the class of similar rooms using a handheld H2O2
sensor, use the time established by that protocol.
B. If you have a handheld H2O2 sensor but no protocol, reenter the room after at least 90 minutes with PPE
to determine if the measured H2O2 level has dropped to about 1 ppm or below.
C. If no written protocol has been established and you have no H2O2 sensor, assume a waiting time of AT
LEAST 110 MINUTES AFTER FOGGING. (110 minutes is the minimum wait time. Length of wait time increases
with room size. See time chart below.)
Minimum Wait Times
Fog Time Recommended MINIMUM Wait Time
10 minutes 110 minutes
15 120
20 130
25 140
30 150
35 160
40 170
45 180
50 190
55 200
60 210
Once the reentry time has been reached or exceeded, it is recommended that you open all doors, windows
(if any), unseal HVAC vents and restart your HVAC system to allow increased ventilation and airow
circulation in the room. Uncover smoke detectors.
HaloFogger® Operation Manual_1911
Timer Setting
ft3m3
Fog Times (based on room size)
1400 - 1,800
1,900 - 2,600
2,700 - 3,500
3,600 - 4,400
4,500 - 5,200
5,300 - 6,100
6,200 - 7,000
7,100 - 7,900
8,000 - 8,800
8,900 - 9,600
9,700 - 10,500
40 - 50
51 - 75
76 - 100
101 - 125
126 - 150
151 - 175
176 - 200
201 - 225
226 - 250
251 - 275
276 - 300
10
15
20
25
30
35
40
45
50
55
60
minutes

Special Instructions -
Fogging a Room With a Second Room
a. When fogging a room with a second interior room (example: bathroom in a hospital patient room),
measure the length, width and height of both rooms, and combine totals to determine nal room size.
b. Position HaloFogger in the smaller interior room with front handle of the device approximately two feet
from doorway, with the nozzle assembly attached to the side of the fogger pointing the nozzle towards the
door opening, on a 45-degree upward angle. (See Figure 1 below.) Keep interior door open so dispensing
path to main room is not blocked.
c. Position the dehumidier, if one is being used, outside the smaller interior room, centered in the doorway,
facing towards the fogger.
d. Use Chemical Indicator Strips to ensure that the aerosolized disinfectant coverage reached around corners
and all surfaces within both rooms. A protocol may require longer fogging times than indicated on the
standard table to ensure that all corners and surfaces are reached properly.
Special Room Prep for Bathrooms:
• Lift toilet lid, leave in “up” position.
• Toilet seat can remain down.
• Remove all towels, gowns and porous items from room. Shower curtains are generally not removed but are
opened so as to allow free circulation of the aerosol into the shower area and around the curtain itself.
HaloFogger® Operation Manual_1911

HaloFogger® Operation Manual_1911
How to Use the HaloLog™ Data Logger
Compatible with Apple® iDevices and Android® Devices that have Bluetooth 4.0
The HaloLog™ App free of charge to download.
For Apple® iDevices, please visit the App Store.
For Android® Devices, please visit Google’s Play Store.
What does HaloLog™ App Do:
Keeping track of treatment compliance is important in certain environments. The HaloLog™ allows
applicators to use an Apple® iOS devise (i.e. iPhone or iPad) to:
• Download and view a time-stamped record for treatment cycles via a Bluetooth® connection.
• Ability to record or document treatment location and other information for each cycle on the iOS App.
• View total hours of operation for a specic HaloFogger.
• From the iOS App, download and email a le that contains the date, time, and run duration, along with any
notes, for each HaloFogger operation since rst deployment.
• Monitor dierent HaloFogger units with the same Apple iOS device.
How the HaloLog Feature Works:
The HaloLog data logger features an integrated Bluetooth device with a ‘real time’ clock and sucient
memory to record 30,000 run cycles.
The integrated logger automatically keeps a record of the date and time the HaloFogger starts & stops a
dispensing run. It also keeps track of the total operating hours (dispensing) of the HaloFogger.
With the HaloFogger plugged into a power source, an iOS device with the HaloLog App installed can be
connected to the HaloFogger data logger via Bluetooth. The HaloLog App does not need to be connected
to a fogger before a treatment run is started. The on-board data logger captures all of the operating data,
which can be reviewed later with the HaloLog App after each run, or as necessary.
An operator stands within 10’ of a HaloFogger unit, and opens the HaloLog App. The app searches for
the HaloFogger and once found, the serial number of that HaloFogger will appear. Once a connection is
established, the date, time and duration of the HaloFogger treatment cycles can be viewed on the iOS
device; and notes and/or location details can be entered for each cycle. Note: Only one iDevice with the
HaloLog App installed can be connected to a HaloFogger at a time.
For archiving and printing, a CSV data le can be emailed directly from the HaloLog App and then imported
into Excel for analysis and reporting.
The HaloLog data logger contains a rechareable battery that is charged every time the HaloFogger® is
connected to a power source. If the HaloFogger is used infrequently, it is recommended to leave the device
plugged in overnight once every three months.
System Requirements for compatible Devices
Bluetooth® 4.0 (BT LE), also known as Bluetooth Low Energy and Bluetooth Smart, rst appeared in smart
phones in 2011. It is required for the hando feature of iOS 8 and Yosemite.
Apple Devices: App supports the following Apple devices which are Bluetooth 4.0 equipped:
iPhone • iPhone 4 or newer
iPad • iPad, 3rd generation or newer
Android Devices: • App supports all Android devices that have OS 5.x+ (Lollipop)

1. Plug HaloFogger into a power source. The Status Indicator Light on top of the fogger will illuminate
solid GREEN.
2. Using an iOS device with HaloLog App installed, stand within 10’ of a HaloFogger and open the
HaloLog App.
Connecting HaloLog™ App to HaloFogger®
3. The Halo List Screen will open automatically and begin searching the vicinity for any HaloFogger
equipped with the HaloLog Data Logger option. As the foggers are found, their serial numbers will be
displayed under “Found HaloFoggers.” If no foggers are found, “NONE” will be displayed.
4. To initiate a connection tap on any HaloFogger serial number displayed on the
Halo List Screen. When the connection is made the Run Events Screen will appear.
The top row of the screen will display the fogger’s Serial Number and the Total Run
Time for that unit highlighted in GREEN.
If the operator moves the iDevice out of range (10’ max) the connection will be lost.
The top row will no longer be GREEN and data downloading will be interrupted. To
re-establish the connection, move the iDevice back into range.
Only one iDevice with the HaloLog App installed can be connected to a
HaloFogger at a time.
Continue reading to see ‘screen’ for each action.
Connected. Not Connected.
HaloFogger® Operation Manual_1911

When the HaloLog App is started, the Halo List screen will appear. The the top of the screen will show
“Found HaloFoggers” listed by the fogger’s individual serial number. Only HaloFoggers that are within
range to the HaloLog App will be displayed.
ACTION: Tap on a specic HaloFogger serial number to connect or ‘handshake’ to that fogger.
You will automatically be taken to the Run Events Screen.
The bottom of screen displays “HaloLogs Stored on iDevice.” This is a list of previously downloaded data
logs identied by a fogger’s serial number.
ACTION: Tap on specic HaloFogger serial number to view a previously downloaded run cycle
log for review, editing or sharing. You will automatically be taken to the Run Events Screen to see
this data.
Halo List Screen
The Run Events Screen shows a list of all Run ID’s that have been downloaded to the iDevice.
When a HaloFogger is connected to the iDevice the top row of the screen will display the Serial Number and
total Run Time for that HaloFogger highlighted in GREEN.
The HaloLog data stored on the selected HaloFogger will download automatically after the Bluetooth®
“handshake” has been established, which is indicated when the top row turns GREEN.
Each Run Event is listed with specic information including: Run ID, Room, Building, Operator, Date, Cycle
Start and Stop Time, and duration of run event.
The very bottom row of the screen (highlighted in light BLUE) depicts how many records are kept on the
HaloFogger and how many have been downloaded to the iDevice.
ACTION: Tapping on any run event will open the Run ID Screen where information on that run
cycle can be edited.
Run Events Screen
Button selections at the bottom of screen:
1. Tap to go to Email Screen to send data le by e-mail.
2. Tap to return to Halo List Screen.
3. Tap to go to Utilities Screen to monitor data exchange between iDevice
and HaloFogger.
NOTE: Downloading of data will be interrupted if, during downloading, any input to the iDevice screen is
initiated (tapping to select). Data downloading will resume the next time you re-connect.
Email
Utils
Halo List
HaloFogger® Operation Manual_1911

In this screen, specic information about the treatment cycle can be added. By tapping
on a text block, a room number, building name or location, the name of the operator and
additional comments for that run cycle can be entered.
For convenience, the last entered building name is stored and will come up as a default
for each HaloFogger. The operator information is stored and will come up as a default for
all HaloFoggers monitored by the iDevice.
ACTION: Tap on any text block to update. A keyboard will appear to edit
information. The “Comments’” text block is limited to 178 characters.
Tap when nished to return to Run Events screen.
Run ID Screen
Identifying Run Events as Billable or Non-Billable
For convenience, all run events will identied BILLABLE as a default. Events that are not
treatments (a test run for example) can be identied as NON-BILLABLE. These events will
not appear in the downloadable CSV le, but will be reected in the total HaloFogger
Run Time.
ACTION: Tap on the”Billable” text block to change event to NON-BILLABLE.
Change is highlighted in RED.
Tap when nished to return to Run Events screen.
Done
Done
Deleting Events
Mark events DELETED by pressing the delete button. This function can be used to mark
errors or other unforeseen events. These ID’s will not appear in the downloadable CSV
le and will NOT be reected in the HaloFoggers total time.
ACTION: Tap
A conrmation window will appear. Tap ‘Ok” to continue.
Entire event ID screen will be highlighted in RED.
Tap to return to Run Event Screen.
The run event will appear highlighted in RED with the word DELELTED shown.
Delete
Done
HaloFogger® Operation Manual_1911

The HaloLog app allows logged data to be sent to any email address for reports, archiving and
data back-up.*
ACTION: Tap
Select the range of HaloLog ID’s for download by either manually specifying the starting
and ending ID# or use pre-select buttons to choose a particular selection. The iDevice will
remember the ID# of the “last sent” for each HaloFogger.
ACTION: Tap on the e-mail addresses to which data is to be sent . For convenience,
the last e-mail entered address will be displayed by the iDevice.
Tap to enter new email address.
A keyboard will appear to enter address.
ACTION: Tap to email data.
The iDevice’s email screen will open to conrm message.
ACTION: Tap SEND in upper right corner of screen to send message.
* Back-up data from the HaloFogger® regularly by sending your data by e-mail to a secure
address. Regular back-ups are the best and only protection against hardware failures.
To remove the DELETED identifcation from a Run Event
ACTION: Tap on the RED highlighted Run Event
ACTION: Tap
A conrmation window will appear. Tap ‘Ok” to continue.
The RED highlight and word DELETE are removed.
Tap to return to Run Event Screen.
UnDelete
Done
Email Screen
Send Now
Email
Touch here to enter email address #1
HaloFogger® Operation Manual_1911

Email Screen
The HaloLog App will create a .CSV le and open up the Email screen to send. The .CSV le is easily manipulated in MS Excel. Copy
and paste new records downloaded to an existing le. Each Run ID log can be additionally coded within MS Excel.
The Utility Screen allows the data exchange between the HaloFogger and the iDevice to
be monitored in real time.
This screen allows erasure of any logs on the iDevice.
ACTION: Tap to erase data logs from
iDevice.
Note: Doing this will NOT erase logs and the total Run Time stored on the data logger
inside of the HaloFogger.
Utility Screen
Additional Notes:
1. Only one iDevice can be connected at a time to a HaloFogger.
2. In the event that HaloLogs of the same HaloFogger have been downloaded to multiple devices: If one user has made changes to
the HaloLog (for example added room, building or operator information), any other user must delete the HaloLog listed on their iDevice
(displayed at the bottom of the Halo List screen) then connect to the respective HaloFogger and complete a new download, or connect
and navigate to each Run ID that was changed by someone else and tap the ‘Refresh’ button to update the IDE’s stored data to the
HaloFogger current data for that ID.
3. “Administrator Features” is for factory use only.
4. BACK-UP DATA by e-mailing to a secure e-mail address on a regular basis.
5. Every three months, leave the HaloFogger plugged in overnight to recharge the internal back-up battery.
Erase iDevice Data
HaloFogger® Operation Manual_1911

Maintenance
Nozzle Cleaning and Alignment
To keep your HaloFogger® working at optimum performance, it is recommended that you clean the nozzle
on a regular basis (example: clean nozzle once-a-week if fogger is used once-a-day or more.)
Step 1. Before performing any maintenance to the HaloFogger, disconnect the power cord from the
electrical outlet.
Nozzle Insert
Main Bolt
IMPORTANT - Position Main Bolt so a uniform gap
surrounds the nozzle tip.
Step 2. Remove Nozzle. Using a 5/8” wrench, carefully
turn nozzle counter-clockwise 90º and remove.
Step 3. Separate Parts. Remove Main Bolt from Nozzle
Insert. Soak both parts in soap and water. Rinse parts
thoroughly with water.
Step 4. Reassemble Nozzle. Carefully insert the Main
Bolt back into the Nozzle Insert. Make sure the “wings” on
the Main Bolt nest into the slots down inside the Nozzle
Insert.
Step 5. Carefully reinstall the nozzle into the Halo,
turning nozzle clockwise 90º to lock into place. Test Halo
for straightness of nozzle stream.
Funnel Cleaning
The uid funnel inside the HaloFogger should be checked for debris on a regular basis. Visually inspect the
funnel. If any debris is present, wipe with a clean towel dampened with water.
Ensure that the funnel screen is in place.
HaloFogger® Operation Manual_1911

Troubleshooting
The following table of potential indicators provides a quick reference of the descriptions, probable causes
and most common solutions regarding the operation of the HaloFogger®. If the information in this table
does not describe or solve the problem you are having, contact Customer Service at 1 302-454-8102,
Monday through Friday, 9:00AM to 5:00PM EST.
Symptom Possible Cause Solution
No mist is being
produced
The nozzle is clogged
misaligned.
Remove the nozzle and clean according to
the instructions in this manual.
The disinfectant uid
tank is empty.
Check the uid level indicator lights. If the
orange light is illuminated, follow the ll
instructions in this manual to rell the tank.
Start button not pressed. Press and hold the Start button for 2
seconds to begin fogging.
Green indicator light is
blinking
Reservoir Door is not
closed correctly.
Close Reservoir Door making sure it “clicks”
when closed.
Magnet in Reservoir Door
is not in place.
Call Customer Service.
No power The power cord is not
plugged in or the power
source is not on.
Check to make sure that the power cord is
plugged into both the fogger and the wall
outlet. Then, check to see that the outlet is
working. The green status indicator light
should be illuminated when properly set up.
The fuse is blown. Check to see if the fuse is blown. Fuse (and
a spare) is located behind a discreet panel
just below where the power cord connects
to the HaloFogger.
Knocking noise The compressor is not
running properly.
Call Customer Service.
Disinfecting procedure
is interrupted
Power loss during
treatment process
or other unforeseen
circumstances.
Conrm power has been restored. Re-
enter room after hydrogen peroxide
concentration level is determined to be at
or below 1 ppm. Restart treatment process
from beginning.
HaloFogger® Operation Manual_1911
The unit not plugged in. Check to make sure that the power cord
is plugged into both the HaloFogger and
a wall outlet. Then, check to see that the
wall outlet is working. The green status
indicator light should be illuminated when
properly set up.

Replacement Parts
To order replacement parts, contact Customer Service at 1 302-454-8102, Monday through Friday, 9:00AM to
5:00PM EST.
Part Part Number
110V Power Cord (8’) 0750-110VPC
220V Power Cord (8’) 0750-220VPC
Nozzle Assembly 0750-000
(includes retainer cap,
nozzle insert, main bolt
and O-ring))
Re-Order Number
Part Part Number
110V HaloFogger® (US and Canada) 0753-110
220V HaloFogger® 0753-220
HaloMist™ All-Purpose Disinfectant
1-Case (4x 1-Gallon Bottles) HM10N0G4
Power Module 20PMOD12-110
HaloShield™ Vent Covers
(2-pak bundle only) 0800-SHSVC
Chemical Indicator H202 Test Strips H202STPS-50
HaloFogger® Operation Manual_1911

Photocopy and post outside of room being treated.
CAUTION/PRECAUCION
DO NOT ENTER/ENTERINO
Room Fogging in Progress
Treatment Date / Start Time: Estimated Room Re-entry Time*:
(*Refer to HaloMist™ Use Instructions to determine room re-entry time.)
www.halosil.com

Warranty and Registration
Follow unpacking instructions included with your new HaloFogger. Halosil International is not responsible for
damages caused by incorrect unpacking or transportation of the device.
Halosil International, Inc warrants the HaloFogger, when purchased new, to be free of defects in material
and workmanship and to perform in accordance with manufacturer’s specications for a period of six (6)
months from the date of purchase from a Halosil International Authorized Reseller or Distributor. Halosil
International will either repair or replace any device or component found to be defective or at variance from
manufacturer’s specications within this time period. Halosil International and its authorized distributors
are not responsible for shipping costs associated with warranty returns. Damage resulting from use,
misuse, modication, neglect, accidents, normal wear and tear or shipping is not covered by this or any
warranty.
Halosil International and its authorized distributors assume no liability for any accident, injury, death, loss
or other claim related to or resulting from the use of this device. In no event shall Halosil International or its
authorized distributors be held liable for incidental or consequential damages relating to or resulting from
the use of this device or any of its parts.
This warranty is void if the HaloFogger is not used in accordance with Halosil International’s
recommendations, if repaired, attempted to be repaired, and/or security seals are broken on rear
panel, by an agent other than Halosil International without prior written permission from Halosil
International, or if the HaloFogger has been used with any solution other than Halosil International
disinfectant product. This warranty is available to the original purchasers only and may not be transferred
or assigned.
If during the warranty period your device requires attention most issues can be resolved easily by contacting
Halosil International by phone: +1 (302)-454-8102 Extension 100 or via Email: [email protected]. When
contacting Halosil International please provide the following information: contact name, company name,
contact information (phone and email), address, purchase date, from which HaloFogger was purchased, and
the unit’s serial number. Proof of purchase may be required. If Halosil International determines that the fogger
qualies for warranty coverage, a Return Merchandise Authorization (RMA) number will be issued along with
instructions on where to ship the fogger and emptying the fogger before shipping. Halosil International is
not responsible for shipping costs associated with warranty returns.
It is recommended that the fogger’s original shipping box be retained for return shipping.
Custom-made packaging should be avoided as it will not protect the fogger during shipping.
Halosil International is not responsible for repair costs due to shipping damage.
Prepare the HaloFogger for return shipment to Halosil International including the fogger and all parts packed
in the device’s original shipping box (or one available for purchase from Halosil International). The fogger
must be emptied of all liquid in accordance to shipping instructions sent with RMA number. Halosil is not
responsible for damage caused by uid leakage during return shipping. HaloFoggers that do not qualify for
warranty coverage will be repaired or replaced at the customer’s expense or the device will be returned to the
customer. Halosil International is not responsible for shipping costs associated with repair returns.
Register your purchase to extend your Standard Warranty coverage. Registering your HaloFogger®
purchase will automatically, and at no additional cost, extend the standard six (6) month warranty coverage
to one (1) year from date of purchase. (See Warranty for coverage details.) Registration will also entitle you to
receive information on any product updates as they become available. To qualify for the warranty extension,
registration of the HaloFogger must be completed within thirty-days (30) from original date of purchase from
a Halosil International Authorized Reseller or Distributor.
Register the HaloFogger online: go to www.halosil.com, click on “Register HaloFogger”, or register via email at
[email protected]. Insert “HaloFogger Registration” in the subject line and include the following information:
contact name, company name, contact information (phone and email), address, purchase date, from whom
HaloFogger was purchased, and the unit’s serial number.
HaloFogger® Operation Manual_1911

© 2018 Halosil International HFOM_STD_1911 Made in the USA.
Learn how to reduce infection rates at your facility by visiting
www.halosil.com. There you can nd out more about the Halo
Disinfection System™, download literature and case studies, and nd a
distributor near you.
91 Lukens Drive
New Castle, DE 19720 USA
Tel +1 302-454-8102
Fax +1 302-454-8009
Table of contents
Popular Dehumidifier manuals by other brands

bewello
bewello BW2011B user manual

Omega Altise
Omega Altise OADE16 Operation, maintenance and safety instructions

Frigidaire
Frigidaire FAD301NUD11 use & care

Prem-I-Air
Prem-I-Air EH1208 quick start guide

Royal Sovereign International
Royal Sovereign International RDHC-150P owner's manual

Edison
Edison MH-N Series User and installation manual