Excess water tray
Release clip
Water tray
Operation
light
Power light
Shell Power switch
Filtering disk
Filtering
Heat switch
Motor
cover
Motor
base
Outlet
Outlet
Sensing
device
Sensing
device
Tray
Cover
Power cable
Fuse
Heater
Thermal fuse
Heat switch
Brushed
motor
Power switch
Sensing
probe
Indicator
Temperature
probe
Temperature
switches
Control
relay
Power
L
N
Power
supply
cable
Floor
Fixing point
Metal
installation
board
Power
cable
Water
tray
Water
tray
Release
clip
Sensing
device
Junction box hole
Floor
Raw plugs
102.5mm
User Manual
• Do not open the front panel – electric shock risk
• Do not allow children or adults to pull or hang on
the machine
• Place the unit away from direct water supplies
• A suitably rated fused power supply is required
• Ensure the correct power supply is used, if more
than +/-10% the unit may malfunction
• The power must be turned off during maintenance
• The drain tank and air lter must be installed for
correct operation
• Ensure the unit has a reliable earth connection
• Do not install connected to a power supply
• This hand dryer must be installed by a qualied
electrician
• If the power cord is damaged it must be replaced
by the manufacturer, its service agent or a qualied
person
• A residual current device (RCD) with a rated
residual operating current, not exceeding 30mA
is recommended
• If power tolerance is above +/- 10% the machine
will malfunction
• Please use dedicated spur
• Switch off the power during maintenance
• Excess water tray and lter must be installed
• In case of malfunction, switch off power
immediately
• Ensure power is not connected during installation
Environmental Protection
• Do not dispose of electrical waste with household
waste, please recycle in appropriate facilities.
Check with your Local Authority or retailer for
recycling advice.
WARNING:
INJURY MAY OCCUR IF MISUSED
Prohibited
Do not allow
unit to get
excessively wet
Do not
dismantle
Follow
instructions
carefully
COMPONENTS
ELECTRICAL SCHEMATIC
Crocodillo T2 ........................................1
30mm self tapping screws .............................5
5mm expansion pipe ..................................1
User manual.........................................1
PACKING LIST
External Maintenance
Clean with a soft cloth. If the unit is
very dirty use a soft, dampened cloth
with a neutral cleaning agent,
then polish with a soft, dry cloth
•Only use neutral cleaning agents
•Do not use thinners, acidic or alkaline
toilet cleaners or nylon brushes
(they may damage the surface)
•If using chemical cloths, read instructions rst
•Disinfecting agents will damage the unit
Empty excess water
To prevent water from overowing
it is necessary to regularly empty
the excess water tray
•If the accumulated water is left in the
drain tank it may degrade and start to smell!
•Regularly wash and disinfect the inside
of the drain tank
To clean the filter
Remove the lter unit
DAILY USE & MAINTENANCE
1
2
3
4
This should come
out easily by
holding the raised
piece and pulling
gently downwards
Remove the lter
from the unit
Clean the lter by
tapping or using a
vacuum cleaner
Replace the lter
every 3 years
DO NOT use
water to clean
the lter
Place hands
inside the unit,
palms down
Move backwards
and forwards in
the air ow
Turn hands and
repeat backwards
and forwards
motion
Finally rub hands
together to
remove any nal
dampness
Switch power on
Use as normal
DO NOT install in the following places
•Where the temperature can be below -10°C or above 40°C
•Where the unit may come into direct contact with excessive water
•If the unit will be in direct or strong sunlight
•If there is a lot of condensation in the environment
•If there are corrosive, neutral or reductive gases present
•20m or more below, or 2000m or higher than, sea level
Installation position
The following picture shows the recommended position
• Ensure there is at least 150mm clear space below the machine
(either to the oor or other objects in the location)
• It is recommended that a minimum distance of100mm should
be left clear to either side of the unit
• Avoid locations where people or doors might damage the unit
• Choose a completely at wall surface to mount the unit to
PRE-INSTALLATION PRECAUTIONS
& INSTALLATION LOCATION
Voltage AC220-
2400V~
Motor Brush motor
Phase Single-phase Sensing
distance
9–15cm
Input 1400-1650W Protection
class
IPX4
Air drying
speed
105m/s Unit
dimensions
250 x 175 x
488mm
Heating
power
800-950W Net weight 4.3kg
SPECIFICATION TABLE
Install metal wall plate
•Fix the metal wall plate to the
wall with 5 screws and raw plugs
•A long power cord is supplied
with this machine, trim excess
and connect to junction box
or spur.
Live = brown wire, neutral line = blue
Remove water tray
•Using one hand hold the clip open
whilst pulling the tray out with other hand
Hang the unit
•Hang the unit on the metal wall plate
•Attach the unit to the wall including
5th xing screw behind water tray
Fix metal wall plate screw
•Remove the lter
•Using the single screw, at an angle
of 45°, x the unit through the
lter hole, tighten gently until
the unit is xed rmly to the wall plate
Replace all components
•Replace lter and excess water tray –
See diagram
INSTALLATION
1
3
2
4
5