Hanna Instruments HI 720 User manual

HI720
Calcium Hardness
INSTRUCTION MANUAL
HI720
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI720-25 Reagents for 50 Calcium Hardness Tests
Other Accessories
HI720-11 Calcium Hardness Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass Cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST720 05/18
HI720 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such
bubbles by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
All manuals and user guides at all-guides.com
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking, the
meter is ready.
• Rinse a graduated beaker several times with
unreacted sample, before filling it to the 50
mL mark with sample.
• Add 0.5 mL of HI720A-0 reagent, swirl to mix.
• Add 0.5 mL of HI720B-0 reagent, swirl to mix.
Use this solution to rinse 2 cuvettes before
filling them both up to the 10 mL mark.
• Add 1 drop of HI720C-0 reagent to one cuvette
(#1), replace the cap and invert the cuvette
several times to mix. This is the blank.
• Place the blank (#1) into the meter and close
the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
• Remove the cuvette.
• Insert the second cuvette (#2) into the meter
and press the button.
• The meter directly displays the concentration of
calcium hardness (CaCO3) in ppm. The meter
automatically turns off after 10 minutes.
#1
#2
#1
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI720 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 50 tests
• 100 mL Plastic Beaker (1 pc.)
• 1 mL Syringes with Tips (2 pcs.)
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0.00 to 2.70 ppm
Resolution 0.01 ppm
Accuracy ±0.20 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method
Adaptation of the Standard Methods for the Examination of Water and
Wastewater, 18th edition, Calmagite method. The reaction between
calcium and reagents causes a reddish-violet tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you use
the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
All manuals and user guides at all-guides.com

Other manuals for HI 720

5

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments Nitrite Low HI 707 User manual

Hanna Instruments

Hanna Instruments Nitrite Low HI 707 User manual

Hanna Instruments HI97771 User manual

Hanna Instruments

Hanna Instruments HI97771 User manual

Hanna Instruments HI 93718 User manual

Hanna Instruments

Hanna Instruments HI 93718 User manual

Hanna Instruments HI98198/10 User manual

Hanna Instruments

Hanna Instruments HI98198/10 User manual

Hanna Instruments HI 9811-5 User manual

Hanna Instruments

Hanna Instruments HI 9811-5 User manual

Hanna Instruments HI98165 User manual

Hanna Instruments

Hanna Instruments HI98165 User manual

Hanna Instruments HI 5421 User manual

Hanna Instruments

Hanna Instruments HI 5421 User manual

Hanna Instruments HI 99141 User manual

Hanna Instruments

Hanna Instruments HI 99141 User manual

Hanna Instruments HI 96831 User manual

Hanna Instruments

Hanna Instruments HI 96831 User manual

Hanna Instruments HI 95762C User manual

Hanna Instruments

Hanna Instruments HI 95762C User manual

Hanna Instruments HI 93753 User manual

Hanna Instruments

Hanna Instruments HI 93753 User manual

Hanna Instruments HI 96762 User manual

Hanna Instruments

Hanna Instruments HI 96762 User manual

Hanna Instruments HI 93703-11 User manual

Hanna Instruments

Hanna Instruments HI 93703-11 User manual

Hanna Instruments HI 8033 User manual

Hanna Instruments

Hanna Instruments HI 8033 User manual

Hanna Instruments HI 254 User manual

Hanna Instruments

Hanna Instruments HI 254 User manual

Hanna Instruments HI99165 User manual

Hanna Instruments

Hanna Instruments HI99165 User manual

Hanna Instruments 96728 User manual

Hanna Instruments

Hanna Instruments 96728 User manual

Hanna Instruments Checker HI 721 User manual

Hanna Instruments

Hanna Instruments Checker HI 721 User manual

Hanna Instruments HI9064 User manual

Hanna Instruments

Hanna Instruments HI9064 User manual

Hanna Instruments HI 713 User manual

Hanna Instruments

Hanna Instruments HI 713 User manual

Hanna Instruments HI 99131 User manual

Hanna Instruments

Hanna Instruments HI 99131 User manual

Hanna Instruments EC GroChek User manual

Hanna Instruments

Hanna Instruments EC GroChek User manual

Hanna Instruments HI 96715C User manual

Hanna Instruments

Hanna Instruments HI 96715C User manual

Hanna Instruments HI 96759C User manual

Hanna Instruments

Hanna Instruments HI 96759C User manual

Popular Measuring Instrument manuals by other brands

Schweitzer Engineering Laboratories SEL-734 quick start guide

Schweitzer Engineering Laboratories

Schweitzer Engineering Laboratories SEL-734 quick start guide

Endress+Hauser Prothermo NMT81 operating instructions

Endress+Hauser

Endress+Hauser Prothermo NMT81 operating instructions

IMT Analytics FlowAnalyser Series user manual

IMT Analytics

IMT Analytics FlowAnalyser Series user manual

Larsen & Brusgaard ALTITRACK manual

Larsen & Brusgaard

Larsen & Brusgaard ALTITRACK manual

Novanta SYNRAD Pulstar p100 user manual

Novanta

Novanta SYNRAD Pulstar p100 user manual

LIMIT 1180-R operating manual

LIMIT

LIMIT 1180-R operating manual

Mahr MarCal 30 EWN operating instructions

Mahr

Mahr MarCal 30 EWN operating instructions

HOZO Design MEAZOR User instructions

HOZO Design

HOZO Design MEAZOR User instructions

Endress+Hauser StamoLys CA 70 operating instructions

Endress+Hauser

Endress+Hauser StamoLys CA 70 operating instructions

ITL MON-2697-COM Reference manual

ITL

ITL MON-2697-COM Reference manual

Ecolab EcoTrans II pH operating instructions

Ecolab

Ecolab EcoTrans II pH operating instructions

AEMC instruments MN185 user manual

AEMC instruments

AEMC instruments MN185 user manual

Amprobe VPC-10A user manual

Amprobe

Amprobe VPC-10A user manual

TFA 30.5033 instruction manual

TFA

TFA 30.5033 instruction manual

Testboy TV333 operating manual

Testboy

Testboy TV333 operating manual

ACL 395 Operation manual

ACL

ACL 395 Operation manual

AccuEnergy AcuRev 1300 user manual

AccuEnergy

AccuEnergy AcuRev 1300 user manual

Continental Refrigerator DTCO 1381 Process Guide

Continental Refrigerator

Continental Refrigerator DTCO 1381 Process Guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.