manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments HI 720 User manual

Hanna Instruments HI 720 User manual

HI720
Calcium Hardness
INSTRUCTION MANUAL
HI720
Before using Hanna Instruments products, make sure that they are entirely suitable for
your specific application and for the environment in which they are used. Operation of
these instruments may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct such interferences. Any variation
introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance. To avoid damages or burns, do not put the instrument in microwave oven. For
yours and the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI720-25 Reagents for 50 Calcium Hardness Tests
Other Accessories
HI720-11 Calcium Hardness Certified Standard Kit
HI731225 Cuvette Black Cap for Checker®HC Colorimeters (4 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731321 Glass Cuvettes and Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST720 05/18
HI720 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such
bubbles by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking, the
meter is ready.
• Rinse a graduated beaker several times with
unreacted sample, before filling it to the 50
mL mark with sample.
• Add 0.5 mL of HI720A-0 reagent, swirl to mix.
• Add 0.5 mL of HI720B-0 reagent, swirl to mix.
Use this solution to rinse 2 cuvettes before
filling them both up to the 10 mL mark.
• Add 1 drop of HI720C-0 reagent to one cuvette
(#1), replace the cap and invert the cuvette
several times to mix. This is the blank.
• Place the blank (#1) into the meter and close
the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the meter
is zeroed.
• Remove the cuvette.
• Insert the second cuvette (#2) into the meter
and press the button.
• The meter directly displays the concentration of
calcium hardness (CaCO3) in ppm. The meter
automatically turns off after 10 minutes.
#1
#2
#1
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI720 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 50 tests
• 100 mL Plastic Beaker (1 pc.)
• 1 mL Syringes with Tips (2 pcs.)
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0.00 to 2.70 ppm
Resolution 0.01 ppm
Accuracy ±0.20 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method
Adaptation of the Standard Methods for the Examination of Water and
Wastewater, 18th edition, Calmagite method. The reaction between
calcium and reagents causes a reddish-violet tint in the sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 10 minutes of non-use
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you use
the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.

Other manuals for HI 720

5

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HALO2 HI9810442 User manual

Hanna Instruments

Hanna Instruments HALO2 HI9810442 User manual

Hanna Instruments HI 9813-5 User manual

Hanna Instruments

Hanna Instruments HI 9813-5 User manual

Hanna Instruments HI 93124 User manual

Hanna Instruments

Hanna Instruments HI 93124 User manual

Hanna Instruments HI97711 User manual

Hanna Instruments

Hanna Instruments HI97711 User manual

Hanna Instruments HI 723 User manual

Hanna Instruments

Hanna Instruments HI 723 User manual

Hanna Instruments HI 38020 User manual

Hanna Instruments

Hanna Instruments HI 38020 User manual

Hanna Instruments edge PHM4092 User manual

Hanna Instruments

Hanna Instruments edge PHM4092 User manual

Hanna Instruments HI 98401 User manual

Hanna Instruments

Hanna Instruments HI 98401 User manual

Hanna Instruments HI97737 User manual

Hanna Instruments

Hanna Instruments HI97737 User manual

Hanna Instruments HI 8733 User manual

Hanna Instruments

Hanna Instruments HI 8733 User manual

Hanna Instruments HI97730 User manual

Hanna Instruments

Hanna Instruments HI97730 User manual

Hanna Instruments HI 93723 User manual

Hanna Instruments

Hanna Instruments HI 93723 User manual

Hanna Instruments C 214 User manual

Hanna Instruments

Hanna Instruments C 214 User manual

Hanna Instruments HI 97500 User manual

Hanna Instruments

Hanna Instruments HI 97500 User manual

Hanna Instruments HI 981404N User manual

Hanna Instruments

Hanna Instruments HI 981404N User manual

Hanna Instruments HI 99163 User manual

Hanna Instruments

Hanna Instruments HI 99163 User manual

Hanna Instruments HI 93732N User manual

Hanna Instruments

Hanna Instruments HI 93732N User manual

Hanna Instruments HI 9214 User manual

Hanna Instruments

Hanna Instruments HI 9214 User manual

Hanna Instruments HI 991001 User manual

Hanna Instruments

Hanna Instruments HI 991001 User manual

Hanna Instruments pHep 98107 User manual

Hanna Instruments

Hanna Instruments pHep 98107 User manual

Hanna Instruments PCA 300 Series User manual

Hanna Instruments

Hanna Instruments PCA 300 Series User manual

Hanna Instruments HI 96814 User manual

Hanna Instruments

Hanna Instruments HI 96814 User manual

Hanna Instruments HI97710 User manual

Hanna Instruments

Hanna Instruments HI97710 User manual

Hanna Instruments HI96727 User manual

Hanna Instruments

Hanna Instruments HI96727 User manual

Popular Measuring Instrument manuals by other brands

Voltmaster FCM1 operating manual

Voltmaster

Voltmaster FCM1 operating manual

SICK FLOWSIC100 Flare operating instructions

SICK

SICK FLOWSIC100 Flare operating instructions

NDT James Instruments Aquameter T-M-170 Operator's manual

NDT James Instruments

NDT James Instruments Aquameter T-M-170 Operator's manual

Northern Industrial Tools 486781 owner's manual

Northern Industrial Tools

Northern Industrial Tools 486781 owner's manual

Medisana HG 100 instruction manual

Medisana

Medisana HG 100 instruction manual

Triplett CableRater instruction manual

Triplett

Triplett CableRater instruction manual

BT Redcare GSM STU EV User's installation guide

BT Redcare

BT Redcare GSM STU EV User's installation guide

Sealey VSE9540 manual

Sealey

Sealey VSE9540 manual

Deviser DS2400T Operation manual

Deviser

Deviser DS2400T Operation manual

UEi C161 instruction manual

UEi

UEi C161 instruction manual

Endress+Hauser Proline 10 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline 10 Brief operating instructions

Radians Innova EnviroMentor Field Finder User instructions

Radians Innova

Radians Innova EnviroMentor Field Finder User instructions

Extech Instruments 45160 user guide

Extech Instruments

Extech Instruments 45160 user guide

THORLABS M2MS-BC106N Series quick start

THORLABS

THORLABS M2MS-BC106N Series quick start

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Saluki Technology S3302A datasheet

Saluki Technology

Saluki Technology S3302A datasheet

RADIOMETER FLEX ABL90 Reference manual

RADIOMETER

RADIOMETER FLEX ABL90 Reference manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.