manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Hanna Instruments
  6. •
  7. Measuring Instrument
  8. •
  9. Hanna Instruments HI736 User manual

Hanna Instruments HI736 User manual

HI736
Phosphorus Ultra Low Range
INSTRUCTION MANUAL
Before using Hanna Instruments products, make sure that they are entirely suitable for your
specific application and for the environment in which they are used. Any variation introduced
by the user to the supplied equipment may degrade the meter’s performance. For yours and
the instrument safety do not use or store the instrument in hazardous environments.
Recommendations for Users
Accessories
Reagent Sets
HI736-25 Reagents for 25 Phosphorus Ultra Low Range tests
Other Accessories
HI736-11 Phosphorus ULR Certified Standard Kit
HI731315 Glass Cuvettes and Caps for Checker®HC Colorimeters (2 pcs.)
HI731318 Cloth for wiping cuvettes (4 pcs.)
HI731353 Cuvette Seal Cap for Checker®HC Colorimeters (4 pcs.)
HI740028P 1.5V AAA batteries (12 pcs.)
HI93703-50 Cuvette cleaning solution (230 mL)
IST736 07/18
HI736 is warranted for a period of one year after date of purchase against defects in
workmanship and materials when used for their intended purpose and maintained according
to instructions. This warranty is limited to repair or replacement free of charge. Damage due
to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service
is required, contact your local Hanna Instruments Office. If under warranty, report the model
number, date of purchase, serial number and the nature of the problem. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the instrument is to
be returned to Hanna Instruments, first obtain a Return Goods Authorization number from the
Technical Service department and then send it with shipping costs prepaid. When shipping any
instrument, make sure it is properly packed for complete protection.
Warranty
• It is important that the sample does not contain any debris.
• Whenever the cuvette is placed into the measurement cell, it
must be dry outside, and completely free of fingerprints, oil and
dirt. Wipe it thoroughly with HI731318 or a lint-free cloth prior
to insertion.
• Shaking the cuvette can generate bubbles, causing higher
readings. To obtain accurate measurements, remove such bubbles
by swirling or by gently tapping the cuvette.
• Do not let the reacted sample stand for too long after reagent
is added, as accuracy will be affected.
• After the reading it is important to immediately discard the
sample, otherwise the glass might become permanently stained.
Tips for an Accurate Measurement
To save the battery, the instrument shuts down after 3 minutes of non-use and 2 minutes.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead the
instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
• Turn the instrument off by holding the button until the meter shuts off.
• Turn the instrument upside down and remove the battery cover with a screwdriver.
• Remove the battery from its location and replace it with a new one, inserting the negative
end first.
• Insert the battery cover and replace the screw with a screwdriver.
Battery Management
• Turn the meter on by pressing the button. All
segments will be displayed. When the display
shows “Add”, “C.1” with “Press” blinking,
the meter is ready.
• Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
• Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
• Remove the cuvette from the meter and
unscrew the cap. Add the content of one
packet of HI736-0 reagent. Replace the cap
and shake gently for 2 minutes until the
powder is completely dissolved. Place the
cuvette back into the meter.
• Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement) or,
alternatively, wait for 3 minutes and press
the button.
• The instrument directly displays the
concentration of phosphorus in ppb. The
meter automatically turns off after 2 minutes.
Light High: There is too much light to perform a measurement. Please
check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement. Please
check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0” indicates that the sample absorbs less
light than the zero reference. Check the procedure and make sure you
use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the meter.
Measurement Procedure
Hanna Instruments reserves the right to modify the design, construction or appearance of
its products without advance notice.
Cover
Cuvette with cap
Cuvette holder
LCD Liquid Crystal Display
Operation Button
Functional Description
Errors and Warnings
Thank You
Thank you for choosing a Hanna Instruments product. Please read this instruction
manual carefully before using the instrument.
For more information about Hanna Instruments and our products, visit
www.hannainst.com.
For technical support, contact your local Hanna Instruments Office or e-mail us at
[email protected].
Find your local Hanna Instruments Office on www.hannainst.com.
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please contact your local Hanna Instruments Office.
Each HI736 meter is supplied complete with:
• Sample Cuvettes and Caps (2 pcs.)
• Reagents for 6 tests
• 1.5V AAA Battery (1 pc.)
• Instruction Manual and Quick Reference Guide
Preliminary Examination
Range 0 to 200 ppb
Resolution 1 ppb
Accuracy ±5 ppb ±5% of reading @25 °C/77 °F
Light Source Light Emitting Diode @525 nm
Light Detector Silicon Photocell
Method
Adaptation of the Standard Methods for the Examination of Water
and Wastewater, 20Th edition, Ascorbic Acid method. The reaction
between phosphorus and the reagent causes a blue tint in the
sample.
Environment 0 to 50 °C (32 to 122 °F); max 95% RH non-condesing
Battery Type 1.5V AAA (1 pc.)
Auto-Shut off After 3 minutes of non-use or 2 minutes after reading
Dimensions 86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)
Weight 52 g (1.84 oz.)
Specifications

Other manuals for HI736

1

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HALO 2 HI9810432 User manual

Hanna Instruments

Hanna Instruments HALO 2 HI9810432 User manual

Hanna Instruments HI 8424NEW User manual

Hanna Instruments

Hanna Instruments HI 8424NEW User manual

Hanna Instruments HI 9219 User manual

Hanna Instruments

Hanna Instruments HI 9219 User manual

Hanna Instruments HI 99121 User manual

Hanna Instruments

Hanna Instruments HI 99121 User manual

Hanna Instruments HI 99301 User manual

Hanna Instruments

Hanna Instruments HI 99301 User manual

Hanna Instruments PCA 310 User manual

Hanna Instruments

Hanna Instruments PCA 310 User manual

Hanna Instruments Chromium VI User manual

Hanna Instruments

Hanna Instruments Chromium VI User manual

Hanna Instruments HI 96770 User manual

Hanna Instruments

Hanna Instruments HI 96770 User manual

Hanna Instruments HI97769 User manual

Hanna Instruments

Hanna Instruments HI97769 User manual

Hanna Instruments HI 95729C User manual

Hanna Instruments

Hanna Instruments HI 95729C User manual

Hanna Instruments HI775 User manual

Hanna Instruments

Hanna Instruments HI775 User manual

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments

Hanna Instruments DiST HI 98302 User manual

Hanna Instruments HI 9835 User manual

Hanna Instruments

Hanna Instruments HI 9835 User manual

Hanna Instruments HI 93102 User manual

Hanna Instruments

Hanna Instruments HI 93102 User manual

Hanna Instruments HI 701 User manual

Hanna Instruments

Hanna Instruments HI 701 User manual

Hanna Instruments HI97752 User manual

Hanna Instruments

Hanna Instruments HI97752 User manual

Hanna Instruments HI 140 Series User manual

Hanna Instruments

Hanna Instruments HI 140 Series User manual

Hanna Instruments HI 95715 User manual

Hanna Instruments

Hanna Instruments HI 95715 User manual

Hanna Instruments HI 95734C User manual

Hanna Instruments

Hanna Instruments HI 95734C User manual

Hanna Instruments HI 93714 User manual

Hanna Instruments

Hanna Instruments HI 93714 User manual

Hanna Instruments HI 96759C User manual

Hanna Instruments

Hanna Instruments HI 96759C User manual

Hanna Instruments HI 98402 User manual

Hanna Instruments

Hanna Instruments HI 98402 User manual

Hanna Instruments HI 84181 User manual

Hanna Instruments

Hanna Instruments HI 84181 User manual

Hanna Instruments HI7630-28 User manual

Hanna Instruments

Hanna Instruments HI7630-28 User manual

Popular Measuring Instrument manuals by other brands

wtw Cond 3110 quick start guide

wtw

wtw Cond 3110 quick start guide

Benning MM 5-2 operating manual

Benning

Benning MM 5-2 operating manual

BIRD 7027 Series Operation manual

BIRD

BIRD 7027 Series Operation manual

Colibri SMARTHUB user manual

Colibri

Colibri SMARTHUB user manual

Ametek WDG-V user manual

Ametek

Ametek WDG-V user manual

Citec LOOP420 instruction manual

Citec

Citec LOOP420 instruction manual

Mezon DSTM500 user manual

Mezon

Mezon DSTM500 user manual

Flexim FLUXUS F704**-NN Series user manual

Flexim

Flexim FLUXUS F704**-NN Series user manual

pH ELECTRODE PE-03 Operation manual

pH ELECTRODE

pH ELECTRODE PE-03 Operation manual

Honeywell DVC100 (M) MK2 installation guide

Honeywell

Honeywell DVC100 (M) MK2 installation guide

Milwaukee MW101 user manual

Milwaukee

Milwaukee MW101 user manual

Decagon Devices KD2 Pro Operator's manual

Decagon Devices

Decagon Devices KD2 Pro Operator's manual

Doepke DCTR B-X Installation and operating instructions

Doepke

Doepke DCTR B-X Installation and operating instructions

Smart Storm Universal Smart Meter instruction manual

Smart Storm

Smart Storm Universal Smart Meter instruction manual

M-system AS4M instruction manual

M-system

M-system AS4M instruction manual

Rixen SR-496 instruction manual

Rixen

Rixen SR-496 instruction manual

Vetek MO.DTR.526.R6 operating manual

Vetek

Vetek MO.DTR.526.R6 operating manual

ThermoWorks ThermaQ 2 operating instructions

ThermoWorks

ThermoWorks ThermaQ 2 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.