Hanna Instruments HUALIX HI 715 User manual

Ammonia Medium Range Preliminary examination:
Please examine this product carefully. Make sure that the instrument is not damaged. If
any damage occurred during shipment, please notify your Dealer.
Each HI 715 meter is supplied complete with:
• Two Sample Cuvettes and Caps
• One bottle of Reagent A
• One bottle of Reagent B
• 1 x 1.5V AAA Battery
• Instruction Manual
HI 715
Functional description:
Errors and warnings:
Light High: There is too much light to perform a measurement.
Please check the preparation of the zero cuvette.
Light Low: There is not enough light to perform a measurement.
Please check the preparation of the zero cuvette.
Inverted Cuvettes: The sample and the zero cuvette are inverted.
Under Range: A blinking “0.00” indicates that the sample absorbs
less light than the zero reference. Check the procedure and make sure
you use the same cuvette for reference (zero) and measurement.
Over Range: A flashing value of the maximum concentration indicates
the reading is over range. Dilute the sample and re-run the test.
Battery Low: The battery must be replaced soon.
Dead Battery: This indicates that the battery is dead and must be
replaced. Once this indication is displayed, normal operation of the
instrument will be interrupted. Change the battery and restart the
meter.
1. Dust cover.
2. Cuvette with cap.
3. Cuvette holder.
4. Liquid Crystal Display.
5. Button.
For more details about spare parts and accessories
see “Accessories”.
www.hannainst.com
Dear Customer,
Thank you for choosing a Hanna Instruments Product.
Please read this instruction manual carefully before using the instrument. If you need
additional technical information, do not hesitate to e-mail us at [email protected]
or view our worldwide contact list at www.hannainst.com.
Technical specifications:
Range 0.00 to 9.99 ppm NH3-N
Resolution 0.01 ppm
Accuracy ±0.05 ppm ±5% of reading @ 25 °C / 77 °F
Light Source Light Emitting Diode @ 470 nm
Light Detector Silicon Photocell
Method Adaptation of the
ASTM Manual of Water and Environmental
Technology, D1426-93,
Nessler Method. The reaction
between ammonia and reagents causes a yellow tint in
the sample.
Environment 0 to 50 °C (32 to 122 °F);
max 95% RH non-condensing
Battery Type 1 x 1.5V AAA
Auto-Shut off After 10 minutes of non-use
Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight 64 g (2.25 oz.)
10 mL
•It is important that the sample does not contain any debris.
•Whenever the cuvette is placed into the measurement cell, it must be dry
outside, and completely free of fingerprints, oil and dirt. Wipe it thoroughly with
HI 731318 or a lint-free cloth prior to insertion.
•Shaking the cuvette can generate bubbles, causing higher readings. To obtain
accurate measurements, remove bubbles by swirling or by gently tapping the
cuvette.
•Do not let the reacted sample stand for too long after reagent is added, as
accuracy will be affected.
•After the reading it is important to immediately discard the sample, otherwise
the glass might become permanently stained.
REAGENT SETS
HI 715-25 Reagent set for 25 Ammonia Medium Range tests
OTHER ACCESSORIES
HI 715-11 Ammonia MR Certified Standard Kit
HI 731318 Cloth for wiping cuvettes (4 pcs.)
HI 731321 Glass cuvettes (4 pcs.)
HI 731225 Cuvette black cap for checker HC (4 pcs.)
HI 731353 Cuvette seal cap for checker HC (4 pcs.)
HI 740028 1.5V AAA batteries (4 pcs.)
HI 93703-50 Cuvette cleaning solution (230 mL)
Recommendations for Users
Before using this product, make sure that it is entirely suitable for your specific application and for the
environment in which it is used.
Operation of this instrument may cause unacceptable interferences to other electronic equipment, thus
requiring the operator to take all necessary steps to correct interferences.
Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC
performance.
To avoid damage or burns, do not put the instrument in microwave oven. For the safety of you and the
instrument do not use or store the instrument in hazardous environments.
For additional information, contact your
dealer or the nearest
Hanna Customer Service Center.
To find a Hanna Office in your area,
visit our web site:
www.hannainst.com
Hanna Instruments reserves the right to modify the design, construction or
appearance of its products without advance notice.
Battery management
To save the battery, the instrument shuts down after 10 minutes of non-use.
One fresh battery lasts for a minimum of 5000 measurements. When the battery is dead
the instrument will display “bAd” then ”bAt” for 1 second and then turns off.
To restart the instrument, the battery must be replaced with a new one.
To replace the instrument’s battery:
•Turn the instrument off by holding the button until the meter shuts off.
•Turn the instrument upside down and remove the battery cover with a screwdriver.
•Remove the battery from its location and replace it with a new one, inserting the
negative end first.
•Insert the battery cover and replace the screw with a screwdriver.
IST715 03/13
Measurement procedure: Accessories:Tips for an accurate measurement
•Turn the meter on by pressing the button.
All segments will be displayed. When the
display shows “Add”, “C.1” with “Press”
blinking, the meter is ready.
•Fill the cuvette with 10 mL of unreacted
sample and replace the cap. Place the cuvette
into the meter and close the meter’s cap.
•Press the button. When the display shows
“Add”, “C.2” with “Press” blinking the
meter is zeroed.
•Remove the cuvette from the meter and
unscrew the cap. Add 4 drops of HI 715A-0
reagent A. Replace the cap and swirl the
solution.
•Unscrew the cap and add 4 drops of HI 715B-0
reagent B. Replace the cap and swirl the
solution. Place the cuvette back into the
meter.
•Press and hold the button until the timer is
displayed on the LCD (the display will show
the countdown prior to the measurement)
or, alternatively, wait for 3 minutes and
30 seconds and press the button.
•The instrument displays the results in mg/L
(ppm) of ammonia nitrogen (NH3-N). To
convert the reading to ppm of ammonia
(NH3), multiply the reading by factor of
1.214. The meter automatically turns off
after 10 minutes.

Other Hanna Instruments Measuring Instrument manuals

Hanna Instruments HI96729 User manual

Hanna Instruments

Hanna Instruments HI96729 User manual

Hanna Instruments HI 2221 User manual

Hanna Instruments

Hanna Instruments HI 2221 User manual

Hanna Instruments Pool Line HI987134 User manual

Hanna Instruments

Hanna Instruments Pool Line HI987134 User manual

Hanna Instruments HI96716C User manual

Hanna Instruments

Hanna Instruments HI96716C User manual

Hanna Instruments HI99151 User manual

Hanna Instruments

Hanna Instruments HI99151 User manual

Hanna Instruments HI 93714 User manual

Hanna Instruments

Hanna Instruments HI 93714 User manual

Hanna Instruments HI 95759 User manual

Hanna Instruments

Hanna Instruments HI 95759 User manual

Hanna Instruments HI 96804 User manual

Hanna Instruments

Hanna Instruments HI 96804 User manual

Hanna Instruments Checker HI726 User manual

Hanna Instruments

Hanna Instruments Checker HI726 User manual

Hanna Instruments HI 991001 User manual

Hanna Instruments

Hanna Instruments HI 991001 User manual

Hanna Instruments HI 4104 User manual

Hanna Instruments

Hanna Instruments HI 4104 User manual

Hanna Instruments HI99165 User manual

Hanna Instruments

Hanna Instruments HI99165 User manual

Hanna Instruments HI 93703-11 User manual

Hanna Instruments

Hanna Instruments HI 93703-11 User manual

Hanna Instruments HI 931400 User manual

Hanna Instruments

Hanna Instruments HI 931400 User manual

Hanna Instruments HI 84429 User manual

Hanna Instruments

Hanna Instruments HI 84429 User manual

Hanna Instruments HI96101C User manual

Hanna Instruments

Hanna Instruments HI96101C User manual

Hanna Instruments HI 9812 User manual

Hanna Instruments

Hanna Instruments HI 9812 User manual

Hanna Instruments HI97717 User manual

Hanna Instruments

Hanna Instruments HI97717 User manual

Hanna Instruments HI96785 User manual

Hanna Instruments

Hanna Instruments HI96785 User manual

Hanna Instruments HI 93737 User manual

Hanna Instruments

Hanna Instruments HI 93737 User manual

Hanna Instruments HI 717 User manual

Hanna Instruments

Hanna Instruments HI 717 User manual

Hanna Instruments Checker HI701 User manual

Hanna Instruments

Hanna Instruments Checker HI701 User manual

Hanna Instruments PRIMO 5 User manual

Hanna Instruments

Hanna Instruments PRIMO 5 User manual

Hanna Instruments HI 97500 User manual

Hanna Instruments

Hanna Instruments HI 97500 User manual

Popular Measuring Instrument manuals by other brands

enertexbayern Enertex KNX Smartmeter 85A (RT) Manual and Configuration

enertexbayern

enertexbayern Enertex KNX Smartmeter 85A (RT) Manual and Configuration

IKALOGIC SP259 Series Datasheet and User Manual

IKALOGIC

IKALOGIC SP259 Series Datasheet and User Manual

Delta OHM HD 2013 Series quick start guide

Delta OHM

Delta OHM HD 2013 Series quick start guide

Delta UNO-C07X011 quick start guide

Delta

Delta UNO-C07X011 quick start guide

Metrix SA6200A installation manual

Metrix

Metrix SA6200A installation manual

AimTTi PSA6005 Short guide

AimTTi

AimTTi PSA6005 Short guide

HANYOUNG NUX BA 1 Series instruction manual

HANYOUNG NUX

HANYOUNG NUX BA 1 Series instruction manual

Pro's Kit MT-4616 user manual

Pro's Kit

Pro's Kit MT-4616 user manual

B+K precision 2708B operating instructions

B+K precision

B+K precision 2708B operating instructions

HANYOUNG NUX MP3 instruction manual

HANYOUNG NUX

HANYOUNG NUX MP3 instruction manual

AimTTi HA1600A instruction manual

AimTTi

AimTTi HA1600A instruction manual

Tek-Trol Tek-Flux 1400A instruction manual

Tek-Trol

Tek-Trol Tek-Flux 1400A instruction manual

Ntron MINI ID Operation manual

Ntron

Ntron MINI ID Operation manual

PRO-TEK 3201 user manual

PRO-TEK

PRO-TEK 3201 user manual

Lake Shore 460 user manual

Lake Shore

Lake Shore 460 user manual

B meters LORA-PULSE LORAWAN pulse manual

B meters

B meters LORA-PULSE LORAWAN pulse manual

Promax PROLITE-53B Quick reference guide

Promax

Promax PROLITE-53B Quick reference guide

Care Fusion BabyCO operating manual

Care Fusion

Care Fusion BabyCO operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.