Hardmeier FoxSec FS9000 Quick start guide

Main panel has total of 16 inputs (expandable up to 240) and 8 relay
outputs on board. Inputs are montiored with two 2.2 ohm resistor
system.
•Data on the Ethernet is encrypted
•Up to 48 LCD/LED keypads for one main unit
•Up to 14 16in/8out zone expander modules
Up to 240 zones and 112 outputs
Up to 24 8out main output modules and each one expandable
up to 32 additional outputs Total of 960 outputs
•Up to 31 access door controllers (FS7001, FS7002, FS8001,
FS8002) for one main unit
For one main unit can be connected 1 GSM modem, 1 CONTACT ID
module or connection with PC through serial COM port.
For data communication must be used shielded twisted pair cable
(Cat5e, Cat6e)
Data communication cable total lengths:
eypads/output modules BD line total length is up to 1500m
Zone expander modules SENS line total length is up to 2000m
Access door controllers DOORS line total length is up to 1000m
FS9000 main unit DIP switches are used for enabling and disabling
technical options.
1. If it is ON then it is possible to connect PC to FoxSec through
RS232 COM port and monitoring nor will conf software ask for
user neither password nor encryption keys. When enabling this
then main unit creates an alarm ‘engineer on site’ and it will be
on until switch is turned off. Option is needed when passwords
or encryption keys are lost and must create new ones.
NB! As long as DIP 1 is ON access door controller data line
is not working.
2. If it is ON then it is possible to connect PC to FoxSec through
Ethernet. Neither monitoring nor will conf software ask for user
neither password nor encryption keys. When enabling this then
main unit creates an alarm ‘engineer on site’ and it will be on
until switch is turned off. (Can be connected if Ethernet settings
are enabled and working)
3. If enabled then access door controller alarms are not shown
(door opened too long, door opened by key, etc).
4. If enabled then main unit will not monitor (220VAC) critical
limits. If it is OFF then alarm is generated if mains supply is
under 190V or above 240V.
5. Must be OFF all the time
6. If it is on then it is possible to connect zone expanders,
keypads, output modules to one ( BD) data line. Access door
controllers must still connect to DOORS data line.
Main board LED
1. BD data line supervision –
If BD LINE LED is ON then it is programmed to main unit at
least one keypad and/or output module and all connected
devices are communicating with main unit.
If LED is OFF then there are no devices programmed to main
unit.
If LED blinks then at least one of the programmed devices is
not communicating with FoxSec main unit.
2. SENS data line supervision –
If SENS LINE LED is ON then it is programmed to main unit at
least one zone expander module and data connection is
perfect. If LED is OFF then there are no devices programmed
to main unit. If LED blinks then there is some kind of outside
noise to data line.
3. RS232 data line supervision –
If blinking then it is sending and receiving data over COM port
Green= transmit (TX), Red= receive (RX).
FoxSec FS9000 ver. 5.5
TECHNICAL DEVICE SPECIFICATION
Type FS9000 Alarm system main panel
Security grade at. 3 PD6662:2004 EN50131-1
Mounting box size 400X350X180 mm
Environmental class IP 20
PCB dimensions 160X264 mm
Input power 13.7VDC
Current 400mA
Outputs 8 X 5A relay outputs
Inputs 16 on board inputs. 2 X 2.2 ohm
Antitamper Sepparate inputs for tampers
Temperature range -10 ºC to +40 ºC
Humidity range 0%-80%
Communications Ethernet, CAN bus, RS485, RS232

BASIC SAFETY EQUI EMENTS
Before using this electrical device read all of the safety instructions and
device manual and be sure you understand it clearly. eep all of the
documentation for further use and give it to the next user with the device.
Warning
Some of the FoxSec devices use mains power 230V/50Hz.
Start of operation
Before plugging in the device check to see that the rated mains voltage
and mains frequency, as stated on the rating label, match with your
power supply.
Environmental protection
Worn out electrical devices contain considerable
amounts of valuable raw and plastic materials, which
can be recycled.
Only for EU countries:
Newer dispose of electrical devices in your household
waste! In accordance with European Guideline
2002/96/EC on used electronic and electric
equipment and its implementation in national legal
systems, used electrical devices must be collected
separately and handed in for environ-mentally compatible recycling.
SAFETY P ECAUTIONS
Warning: Read these instructions before use. Pay special attention to
the safety information. These instructions are intended for persons having
a basic technical knowledge of the operation of electrical devices such as
the one described herein. If you have no experience whatsoever with
such devices, we strongly recommend that you seek the advice of an
experienced person.
Installation and maintenance works can be done only by qualified
personnel
Check general requirements.
1. eep devices area tidy.
Consider environmental conditions. Do not expose the machine to rain.
Do not leave device in damp or wet environment.
2. Do not use the device near inflammable liquids or gases.
3. Risk of electric shock! Prevent body contact with earthed objects such
as radiators, pipes, cooking stoves or refrigerators when operating this
4. If the device is not in use store it in a cool dry place away of reach of
children.
5. Do not overload device. It will work safely and perfectly in stated limits.
6. Do not use the mains cable for any purpose it is not intended for.
7. Disconnect power before servicing.
8. Disconnect power if it is not in use.
9. Use only special installation box and cables for installing the device
into outdoor conditions
10. Be alert. now what you are doing. Do not operate device while
under the influence of drugs, alcohol or medication!
11. Before using the device check that it is not broken in any way. In case
of discovering a defect on the device, let it check by authorized personnel
only.
12. All devices must be installed only those places that has enough
space to work normally.
13. Use only those additional devices mentioned in this manual. If using
other kind of additional devices, main device may not work properly or
even broke the device.
14. Let the device maintenance be done by authorized personnel only.
NB! Save these instructions.
Important!
ead these instructions before use. Pay special attention to the
safety information. These devices must be installed, maintenance
and repaired by authorized personnel only. Any purpose it is not
intended for may cause fatal failure to the system or even but in
danger personnel nearby
LIMITED WA ANTY
Hardmeier OÜ ("Hardmeier") warrants that the electronical component(s)
sold by Hardmeier, or by either a distributor or stocking representative
franchised by Hardmeier to sell electronical component(s) manufactured
by Hardmeier (the "Electronical Component(s)"), are free from
Manufacturing Defects (as defined and as determined below) for a period
of one (1) year from the date of sale to the customer, subject to and on
the terms and conditions set forth in this Limited Warranty. Hardmeier will
remedy and correct any "Manufacturing Defects," with respect to the
Electronical Component(s), during the one (1) year Limited Warranty
period, by, at Hardmeier's sole option replacing, at Hardmeier's cost and
expense, the Electronical Component(s) with the same or substantially-
similar specifications, provided that (in addition to any other requirements
or provisions of this Limited Warranty), the customer returns, with all
shipping costs pre-paid at the customer's sole expense, the Electronical
Component(s) that the customer claims are subject to any Manufacturing
Defects according to Hardmeier's Returned Merchandise Authorization
procedures, as they may exist from time-to-time. Hardmeier is the only
party authorized to remedy and correct any Manufacturing Defects as
provided by this Limited Warranty, and this Limited Warranty does not
apply to replacements of Electronical Component(s), or any other
corrective or remedial action with respect to the Electronical
Component(s), made by any other party.
Definition of "Manufacturing Defects" "Manufacturing Defects" means
Hardmeier verified problems or defects resulting from the manufacture,
materials, or workmanship of the Electronical Component(s) by
Hardmeier that render(s) the Electronical Component(s) unable to
function in a manner consistent with and according to the specifications
provided by and/or defined by Hardmeier that are applicable to the
Electronical Component(s). Furthermore, Hardmeier specifically reserves
the right to: (a) determine, in its sole, absolute discretion, whether a
"Manufacturing Defect(s)" exists; and (b) decline any claim under this
Limited Warranty with respect to an Electronical component that
Hardmeier can not verify, in its sole, absolute discretion, was sold to the
Limited Warranty claimant either directly by Hardmeier or though a
franchised Hardmeier distributor or stocking representative.
Notwithstanding the foregoing, and without limiting the foregoing,
"Manufacturing Defects" are NOT unconfirmed defects or problems
caused by modifications to, or work performed on, the Electronical
Components by any party after the sale of the Electronical Components
by Hardmeier. In addition, "Manufacturing Defects" are NOT unconfirmed
defects or problems caused by utilization of the Electronical Components
in a manner inconsistent with the specifications provided and/or defined
by Hardmeier that are applicable to the Electronical Component(s), or in
any unreasonable manner. Hardmeier reserves the right to void this
Limited Warranty, and shall not be obligated to make any replacements
or credits of the Credit Amount with respect to the Electronical
Component(s) in event that work is performed on the Electronical
Component(s) by any party after the sale of the Electronic Components
by Hardmeier, or if the Electronical Component(s) are used in a manner
inconsistent with the specifications provided and/or defined by Hardmeier
that are applicable to the Electronical Component(s), or are used in an
unreasonable manner. EXCEPT AS SET FORTH IN THIS LIMITED
WARRANTY, HARDMEIER MA ES NO OTHER WARRANTIES,
EITHER EXPRESS OR IMPLIED. FURTHERMORE, HARDMEIER
SHALL NOT BE LIABLE FOR ANY DAMAGES (WHETHER
CONSEQUENTIAL, INCIDENTAL OR OTHERWISE) FOR ANY
BREACH OF THIS LIMITED WARRANTY, EXCEPT FOR HARDMEIER
OBLIGATIONS TO REPLACE THE ELECTRONICAL COMPONENT(S),
AS ELECTED BY HARDMEIER AT HARDMEIER SOLE OPTION, AND
AS MORE PARTICULARLY PROVIDED BY THIS LIMITED WARRANTY,
AND SUCH REPLACEMENTS, AS THE CASE MAY BE, SHALL BE THE
SOLE REMEDY FOR ANY SUCH BREACH BY HARDMEIER OF THIS
LIMITED WARRANTY.
CE TIFICATES
All of the FoxSec devices have CE marking
CE certificate EVS-EN 50130-4; EN 61000-6-x series; EVS-EN 55022
Electromagnetic compatibility (EMC) Testing and measurement EN 61000-4-2
Radiated, radio-frequency, electromagnetic field immunity test EN 61000-4-3
Electrical fast transient/burst immunity test EN 61000-4-4
Surge immunity test EN 61000-4-5
Immunity to conducted disturbances induced by radiofrequency fields EN 61000-4-6
Voltage dips, short interruptions and voltage variations immunity EN 61000-4-11
Radiated electromagnetic fields tests EN 50147-3
Limitation of Voltage Fluctuations and Flicker EN 61000-3-3
Harmonic current emissions tests EN 61000-3-2
Guidelines to achieving compliance with EC directives for alarm systems CLC/TR
50456:2005
Alarm systems - Alarm transmission systems and equipment CLC/TS 50136-4:2004
Alarm systems and alarm transmission systems and equipment CLC/TS 50136-
7:2004
Alarm systems-Combined and integrated alarm systems CLC/TS 50398:2002
Alarm systems-Electromagnetic compatibility EVS-EN 50130-4:2001/A2:2003
Alarm systems-Electromagnetic compatibility EVS-EN 50130-4:2001
Alarm systems-Part 5: Environmental test methods EVS-EN 50130-5:2002
Alarm systems-Intrusion and holdup systems- EVS-EN 50131-1:2006
Alarm systems-Intrusion systems - Power supplies EVS-EN 50131-6:2002
Access control systems use in security applications EVS-EN 50133 1:2002/A1:2003
Access control systems for use in security applications EVS-EN 50133-2-1:2002
Alarm transmission systems and equipment EVS-EN 50136-1-1:2002
Information technology equipment - General requirements EVS-EN 60950-1:2006
Declaration
Our company can not hold responsible for any kind of mistakes in this
manual.
Hardmeier OÜ is the owner of all right, title and interest in the
FoxSec brand and logos. No person or entity may reproduce or use
(or authorize the reproduction or use of) the Hardmeier brands and
logos in any manner other than expressly authorized by Hardmeier.
Unauthorized use of Hardmeier brands and logos is strictly
prohibited.
This manual suits for next models
3