More information - www.harvesthealthcare.co.uk
3 4 Roll the client on to their back and ensure
the sling is aligned and centred.
1 2 Lie the sling flat with the label facing down
on the bed. The bottom edge of the sling
should be set slightly lower than the
client’s knees. Tuck the half which is
nearest to the client underneath them.
HSL410 In Chair Hammock
PLEASE NOTE - THIS SLING SHOULD
ONLY BE APPLIED AND REMOVED ON
A FLAT LYING SURFACE.
Roll the client to one side using a suitable
rolling technique.
Roll the client to the other side exposing the
previously tucked in half of the sling.
Pull out the sling and ensure that the sling is
flat and even.
To ensure safe use, place the large hole of the
clip over the hoist bar stud, pull down on the
clip until it clicks into the narrower neck area.
Ensure that the clip cannot be pulled from the
bar. To remove the clip, pull the small strap
up fully until the large hole is located over the
stud. Failure to fully lift the clip over the stud
when removing can damage the clip retainer
prongs.
6
5 Feed the right leg clip through the small
dignity loop on the left leg.
Feed the clip on the left leg through the short
outer loop of the left leg and the right leg clip
through the short outer loop of the right leg.
Attach the leg clips to the spreader bar
followed by the shoulder clips. Ensure the
sling is square and evenly aligned. Before
attaching the clips to the bar, it is advisable
to profile the bed into a sitting position if
possible.
7 8 At this point it is advisable to hold the
bottom edge of the sling to stop it riding up
the leg during lifting. Raise the hoist until the
clips start to take tension, stop the lift and
ensure that all clips are attached correctly
before completing the lift.
More information - www.harvesthealthcare.co.uk
EXAMINATION AND
INSPECTION OF SLING
CAUTION
Before every lift visually examine the slings
structural integrity. If there is any sign of
excessive damage to the fabric or straps DO
NOT USE THE SLING.
GENERAL EXTERNAL WEAR
In normal use this is unavoidable and is
shown by fluffiness to the surface fibres. This
may be caused by sharp edges on straps or
Velcro. This is harmless unless it becomes
too extensive. Normal material condition is
smooth or flat.
LOCAL ABRASION IN THE WEBBING STRAPS
This may be caused by the passage of the
webbing over the sharp edges whilst under
tension or Velcro. Slight damage to the outer
fibres may be considered safe but in severe
cases this should lead to instant rejection of
the product.
CUTS, HOLES OR BURNS
These are dangerous and must lead to instant
rejection of the product.
EXAMINATION OF STITCH PATTERNS
Examine the stitch patterns for broken, worn,
pulled or unravelled stitches. Reject any
product where the thread has become
subject to excessive abrasion or broken
stitches.
DO NOT USE DO NOT USE
Critical stitch area
on all lifting straps
THIS MUST BE
INTACT
WASHING INSTRUCTIONS
Each sling can be laundered up to 80ºc. Use
a mild soap solution and then rinse. Slings
will air dry quickly in a warm room or in the
normal manner. Tumble dry on low setting
only. Do not place over a convector heater or
steam pipes.
Do not use biological detergents. Do not use
bleach. Do not use strong chemicals. A faded
label is an early indicator that the sling has
been subject to harsh/abrasive cleaning
methods: do not continue to use the sling.
All slings fitted with a Velcro body belt
should have the Velcro square removed
during laundering and refitted afterwards.
This will significantly extend the lifespan of
the product.
SAFE WORKING LOAD
Supersoft (Spacer) - 300kg | Polyester -
400kg | Mesh 300kg | Parachute 200kg
SLING INSPECTION
Each product should be inspected prior to
each use and with your six month or annual
hoist inspection. This is in line with LOLER
(Lifting Operations and Lifting Equipment
Regulations)
SAFETY AND QUALITY STANDARDS
Care-Ability Healthcare (manufacturer),
are registered with the Medicines and
Health Care Regulatory Agency of the UK
Government to manufacture Class 1
Medical Devices. Our products are
categorised as a Class 1 Medical Device
and carry the CE mark under the
European Medical Device Directive
EU93-42. The products are designed and
manufactured under the externally
accredited BS EN ISO 9001:2008 quality
system well beyond the requirements of
BS EN 10535:2006, The Hoist and Sling
Standard.
All of our products are thoroughly
inspected by two staff members prior to
the product being dispatched. Our
Lifestyle slings are labeled with a unique
serial number to assist with traceability
and for recording LOLER examinations.
Harvest Healthcare, Sheaf House, Bradmarsh Way, Bradmarsh Business Park,
Rotherham, S601BW
t: 01709377172 | f: 01709377172 | e: [email protected] |
www.harvesthealthcare.co.uk

Popular Mobility Aid manuals by other brands

Pneumex Pneumex VibroTrac instructions

Pneumex

Pneumex Pneumex VibroTrac instructions

DEMARTA VIRGINIO ROCCIA 01.04.32 user manual

DEMARTA VIRGINIO

DEMARTA VIRGINIO ROCCIA 01.04.32 user manual

Liko Golvo 9000 LowBase Service manual

Liko

Liko Golvo 9000 LowBase Service manual

TOPRO Troja Original Instructions for use

TOPRO

TOPRO Troja Original Instructions for use

PQUIP RBR101 manual

PQUIP

PQUIP RBR101 manual

dynarex 10165 quick start guide

dynarex

dynarex 10165 quick start guide

Invacare H140 user manual

Invacare

Invacare H140 user manual

Timago AMIGO Instructions for use

Timago

Timago AMIGO Instructions for use

Timago RANGER Instructions for use

Timago

Timago RANGER Instructions for use

COMPASS HEALTH PROBASICS BARIATRIC COMMODE BSB24C manual

COMPASS HEALTH

COMPASS HEALTH PROBASICS BARIATRIC COMMODE BSB24C manual

Invacare Dolomite Brass manual

Invacare

Invacare Dolomite Brass manual

Invacare Action 2000 Installation, assembly and operating instructions

Invacare

Invacare Action 2000 Installation, assembly and operating instructions

Arjo Voyager Instructions for use

Arjo

Arjo Voyager Instructions for use

RoMedic BariBar user manual

RoMedic

RoMedic BariBar user manual

Mobilex CB-082 user manual

Mobilex

Mobilex CB-082 user manual

HealthCo Anya user manual

HealthCo

HealthCo Anya user manual

human care Carl-Oskar RECONDITIONING MANUAL

human care

human care Carl-Oskar RECONDITIONING MANUAL

Rifton Stander S410 Quick reference guide

Rifton

Rifton Stander S410 Quick reference guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.