Hayward Salt & Swim User manual

CHEMISTRY QUICK START GUIDE
STEP 1: Calculate Pool Volume
Determine the total number of gallons of water in your
pool using the formulas below. This calculation will be
used frequently when adjusting pool chemical levels
so take care when measuring. For non-standard
shaped pools, it may be easier to break the pool up
into “sections” to make the calculations. When done,
add all the “sections” to determine the total volume of
your pool.
IDEAL RANGE: Before adding salt, test your pool water for the current
level of salt.
RECOMMENDED LEVEL: 2700 - 3400 ppm (3200 ppm ideal)
After testing salt, refer to Table 1 to determine how much salt must be added
to achieve a level of 3200 parts per million (ppm).
Salt should be added directly to the pool with the pool pump on. Brush the
salt around to speed up the dissolving process - do not allow the salt to
pile up on the bottom of the pool. For new plaster pools, wait 10-14 days
before adding salt to allow the plaster to cure. Run the lter pump for 24
hours with the suction coming from the main drain (use pool vac if there is
no main drain) to allow the salt to evenly disperse throughout the pool.
Use common food quality salt usually available in 40-80 lb. bags labeled
“Pool Salt” or “Coarse Solar Salt”. Do not use rock salt, salt with yellow
prussiate of soda, salt with anti-caking additives, or iodized salt.
Cyanuric Acid (Stabilizer) is very important to
the performance of your chlorine generation
system. It’s a mild acid that helps prevent
the breakdown of chlorine due to the sun’s
ultraviolet rays.
IDEAL LEVEL: 60 - 80 ppm outdoor pools
20 - 40 ppm covered pools
0 ppm indoor pools
Test your pool’s Cyanuric Acid level using a
pool test kit or bring a water sample to your
local pool store.
Refer to Table 2 to determine the amount of
Cyanuric Acid needed to raise the Cyanuric
Acid to the desired level.
Total Alkalinity (TA) is a measure of the total
alkaline substances found in the pool water.
The results of improper TA levels range from
corrosion of metal pool parts, staining of the
pool, burning eyes, cloudy water and reduced
chlorine efciency.
IDEAL LEVEL: 80 - 120 ppm
Test your pool’s TA.
Refer to Table 3 to increase the pool’s TA using
Baking Soda (Sodium Bicarbonate 100%).
Refer to Table 4 to decrease the pool’s TAusing
Muriatic Acid (Hydrochloric Acid 31.45%).
Total Hardness is the measurement of the total
amount of minerals that are found in your pool’s
water. Too much calcium hardness will cause
scaling in your pool and too little will cause the
pool water to become corrosive.
IDEAL LEVEL: 200 - 400 ppm
Test your pool’s Total Hardness.
If low, add Calcium Chloride (77%) according
to Table 5.
If Total Hardness is high, dilute or replace the
pool water.
pH is the measure of how acid/alkaline the
pool water is. If pH is too low, the water can
be corrosive to pool equipment. If pH is too
high, then the chlorine becomes much less
effective for sanitization.
IDEAL LEVEL: 7.2 - 7.8
Test your pool’s pH.
To increase the pool’s pH, add Soda Ash
according to Table 6.
To decrease pool pH, add Muriatic Acid
according to Table 7.
OVERVIEW
Before attempting to operate your new chlorine
generator, salt must be added to your pool and
your pool’s water chemistry must be properly
balanced. Properly balanced pool water is not
only necessary for chlorine generation, but also
to protect your pool equipment and users of the
pool.
BECAUSE SOME CHEMICALS INFLUENCE
MORE THAN ONE CHEMISTRY PARAMETER,
IT IS IMPORTANT THAT YOU FOLLOW THE
STEPS IN THE ORDER PRESENTED.
The following steps require the use of a reliable
pool chemical test kit(s).
STEP 2: Adjust Salt Level
STEP 3: Adjust Cyanuric Acid STEP 4: Adjust Total Alkalinity STEP 5: Adjust Total Hardness STEP 6: Adjust pH
Rectangular
Round
Oval
GALLONS
(pool size in feet)
LITERS
(pool size in meters)
Length x Width x
Average Depth x 7.5
Length x Width x
Average Depth x 1000
Length x Width x
Average Depth x 6.7
Length x Width x
Average Depth x 893
Diameter x Diameter x
Average Depth x 5.9
Diameter x Diameter x
Average Depth x 785
WWW.HAYWARD.COM 855-429-9274

092476 RevA
Table 1
Table 2
Table 3
CHEMISTRY QUICK START GUIDE
Table 4
Table 6
Table 7
Table 5
WWW.HAYWARD.COM 855-429-9274
POUNDS and (Kg) OF STABILIZER (CYANURIC ACID) NEEDED FOR80 PPM
Gallons and (Liters) of Pool Water
Current
Stabilizer
level
(ppm)
0 ppm
20 ppm
60 ppm
30 ppm
40 ppm
50 ppm
70 ppm
80 ppm
10 ppm
12,000
(45,000)
8,000
(30,000)
14,000
(52,500)
10,000
(37,500)
16,000
(60,000)
18,000
(67,500)
20,000
(75,000)
22,000
(82,500)
24,000
(90,000)
8.0
(3.6)
5.3
(3.6)
8.0
(3.6)
8.0
(3.6)
9.4
(4.3)
6.7
(4.3)
9.4
(4.3)
10.7
(4.9)
12.0
(5.4)
12.0
(5.4)
13.4
(6.1)
14.7
(6.7)
16.0
(7.3)
7.0
)
(3.2
4.7
(3.2)
8.2
(3.7)
5.8
(3.7)
10.5
(4.8)
11.7
(5.3)
12.9
(5.9)
14.0
(6.4)
6.0
(2.7)
4.0
(2.7)
6.0
(2.7)
6.0
(2.7)
7.0
(3.2)
5.0
(3.2)
9.0
(2.2)
10.0
(4.5)
10.0
(4.5)
11.0
(5.0)
5.0
(2.3)
3.3
(2.3)
5.0
(2.3)
5.9
(2.7)
4.2
(2.7)
6.7
(3.0)
8.4
(3.8)
6.7
(3.0)
7.5
(3.4)
9.2
(4.2)
4.0
(1.8)
2.7
(1.8)
4.0
(1.8)
4.0
(1.8)
4.7
(2.1)
3.3
(2.1)
5.4
(2.4)
7.4
(3.3)
3.0
(1.4)
2.0
(1.4)
3.0
(1.4)
3.5
(1.6)
2.5
(1.6)
4.5
(2.0)
5.5
(2.5)
2.0
(.91)
1.3
(.91)
2.0
(.91)
2.3
(1.1)
1.7
(1.1)
2.7
(1.2)
3.3
(1.5)
3.7
(1.7)
1.0
(.45)
0.7
(.45)
1.2
(.54)
0.8
(.54)
1.4
(.64)
1.5
(.68)
1.7
(.77)
1.8
(.82)
0.00.0 0.00.0 0.0 0.0 0.0 0.0 0.0
POUNDS and (Kg) OF BAKING SODA (SODIUM BICARBONATE 100%)
NEEDED TO INCREASE TOTAL ALKALINITY TO THE RECOMMENDED RANGE
Gallons and (Liters) of Pool Water
Desired
Increase
(ppm)
10 ppm
30 ppm
70 ppm
40 ppm
50 ppm
60 ppm
80 ppm
100 ppm
90 ppm
20 ppm
5,000
(19,000)
400
(1,500)
10,000
(38,000)
1,000
(3,750)
15,000
(57,000)
20,000
(75,000)
25,000
(95,000)
0.7
(0.3)
0.1
(0)
6.3
(2.9)
1.4
(0.6)
4.2
(1.9)
2.1
(1)
2.8
(1.3)
3.5
(1.6)
1.4
)
(0.6
0.1
(0.1)
2.8
(1.3)
5.6
(2.5)
7
(3.2)
2.1
(1)
0.2
(0.1)
14.0
(6.4)
4.2
(1.9)
8.4
(3.8)
10.5
(4.8)
2.8
(1.3)
0.2
(0.1)
21
(9.5)
5.6
(2.5)
0.6
(0.3)
8.4
(3.8)
14
(6.4)
17.5
(7.9)
11.2
(5.1)
3.5
(1.6)
0.3
(0.1)
12.6
(5.7)
7.0
(3.2)
0.7
(0.3)
10.5
(4.8)
4.2
(1.9)
0.3
(0.2)
19.6
(8.9)
8.4
(3.8)
0.8
(0.4)
16.8
(7.6)
4.9
(2.2)
0.4
(0.2)
9.8
(4.4)
1
(0.4)
14.7
(6.7)
24.5
(11.1)
5.6
(2.5)
6.3
(2.9)
7.0
(3.2)
0.4
(0.2)
06
(0.3)
.
11.2
(5.1)
12.6
(5.7)
14
(6.4)
1.1
(0.5)
1.3
(0.6)
1.4
(0.6)
16.8
(7.6)
18.9
(8.6)
21
(9.5)
22.4
(10.2)
25.2
(11.4)
28
(12.7)
28
(12.7)
31.5
(14.3)
35
(15.9)
0.5
(0.2)
0.1
(0.1)
0.3
(0.1)
0.4
(0.2)
OUNCES and (L) OF MURIATIC ACID NEEDED TO
DECREASE TOTA L ALKALINITY TO THE RECOMMENDED RANGE
Gallons and (Liters) of Pool Water
Desired
Decrease
(ppm)
10 ppm
30 ppm
70 ppm
40 ppm
50 ppm
60 ppm
80 ppm
100 ppm
90 ppm
20 ppm
5,000
(19,000)
400
(1,500)
10,000
(38,000)
1,000
(3,750)
15,000
(57,000)
20,000
(75,000)
25,000
(95,000)
13
(0.41)
1
(0)
105
(3.3)
26
(0.81)
78
(2.4)
39
(1.2)
52
(1.6)
65
(2)
26
(0.81)
2
(0.06)
52
(1.6)
105
(3.3)
131
(4)
39
(1.2)
3.2
(0.1)
260
(8.1)
78
(2.4)
157
(4.9)
196
(6)
52
(1.6)
4.2
(0.13)
390
(12.2)
105
(3.3)
10.5
(0.33)
157
(4.9)
260
(8.1)
325
(10.1)
208
(6.5)
65
(2)
5.2
(0.16)
235
(7.3)
131
(4)
13
(0.41)
196
(6)
78
(2.4)
6.2
(0.2)
366
(11.4)
157
(4.9)
15.5
(0.49)
314
(9.8)
91
(2.8)
7.2
(0.23)
183
(5.7)
18
(0.57)
275
(8.5)
457
(14.2)
105
(3.3)
11 8
(3.6)
131
(4.7)
8.4
(0.26)
10.4
(0.32)
208
(6.5)
235
(7.3)
260
(8.1)
21
(0.65)
23.5
(0.73)
26
(0.81)
312
(9.8)
353
(11)
390
(12.2)
416
(13)
470
(14.6)
520
(16.2)
520
(16.2)
588
(17.9)
651
(20.9)
9.4
(0.3)
2.5
(0.08)
5
(0.16)
8
(0.24)
POUNDS and (Kg) OF CALCIUM CHLORIDE (77%) NEEDED TO
INCREASE CALCIUM HARDNESS TO THE RECOMMENDED RANGE
Gallons and (Liters) of Pool Water
Desired
Increase
(ppm)
10 ppm
30 ppm
70 ppm
40 ppm
50 ppm
60 ppm
80 ppm
100 ppm
90 ppm
20 ppm
5,000
(19,000)
400
(1,500)
10,000
(38,000)
1,000
(3,750)
15,000
(57,000)
20,000
(75,000)
25,000
(95,000)
0.6
(0.3)
0
(0)
5.4
(2.5)
1.2
(.5)
3.6
(1.6)
1.8
(.8)
2.4
(1.1)
3
(1.4)
1.2
)
(0.5
0.1
(0)
2.4
(1.1)
4.8
(2.2)
6
(2.7)
1.8
(0.8)
0.1
(0.1)
12.0
(5.5)
3.6
(1.6)
7.2
(3.3)
9
(4.1)
2.4
(1.1)
0.2
(0.1)
18
(8.2)
4.8
(2.2)
0.5
(0.2)
7.2
(3.3)
12
(5.5)
15
(6.8)
9.6
(4.4)
3.0
(1.4)
0.2
(0.1)
10.8
(4.9)
6.0
(2.7)
0.6
(0.3)
9
(4.1)
3.6
(1.6)
0.3
(0.1)
16.8
(7.6)
7.2
(3.3)
0.7
(0.3)
14.4
(6.5)
4.2
(1.9)
0.3
(0.2)
8.4
(3.8)
0.8
(0.4)
12.6
(5.7)
21
(9.5)
4.8
(2.2)
5.4
(2.4)
6.0
(2.7)
0.4
(0.2)
04
(0.2)
.
9.6
(4.4)
10.8
(4.9)
12
(5.4)
1
(0.4)
1.1
(0.5)
1.2
(0.5)
14.4
(6.5)
16.2
(7.3)
18
(9.5)
19.2
(8.7)
21.6
(9.8)
24
(10.9)
24
(10.9)
27
(12.2)
30
(13.6)
0.4
(0.2)
0.1
(0.1)
0.2
(0.1)
0.4
(0.2)
OUNCES AND (GRAMS) OF SODA ASH (SODIUM CARBONATE)
NEEDED TO RAISE pH TO THERECOMMENDED RANGE
Gallons and (Liters) of Pool Water
CURRENT
pH
7.0 - 7.2
under 6.7
6.7 - 7.0
5,000
(19,000)
400
(1,500)
10,000
(38,000)
1,000
(3,750)
15,000
(57,000)
20,000
(75,000)
25,000
(95,000)
4
(113)
0.25
(8.5)
24
(681)
8
(227)
16
(454)
12
(340)
16
(454)
20
(568)
6
)
(170
0.5
(14)
12
(340)
24
(681)
32
(908)
8
(227)
0.6
(17)
16
(454)
32
(908)
40
(1100)
0.75
(21.3)
1.25
(35.4)
1.5
(42.5)
Gallons and (Liters) of Pool/Spa water
12,000 14,000 16,000 18,000 20,000 22,000 24,000
Current salt
level
(45,000) (52,500) (60,000) (67,500) (75,000) (82,500) (90,000)
ppm
0320
(145)
373
(170)
427
(194)
480
(218)
533
(242)
587
(267)
640
(291)
200 300
(136)
350
(159)
400
(182)
450
(205)
500
(227)
550
(250)
600
(273)
400 280
(127)
327
(148)
373
(170)
420
(191)
467
(212)
513
(233)
560
(255)
600 260
(118)
303
(138)
347
(158)
390
(177)
433
(197)
477
(217)
520
(236)
800 240
(109)
280
(127)
320
(145)
360
(164)
400
(182)
440
(200)
480
(218)
1000 220
(100)
257
(117)
293
(133)
330
(150)
367
(167)
403
(183)
440
(200)
1200 200
(91)
233
(106)
267
(121)
300
(136)
333
(152)
367
(167)
400
(182)
1400 180
(82)
210
(95)
240
(109)
270
(123)
300
(136)
330
(150)
360
(164)
1600 160
(73)
187
(85)
213
(97)
240
(109)
267
(121)
293
(133)
320
(145)
1800 140
(64)
163
(74)
187
(85)
210
(95)
233
(106)
257
(117)
280
(127)
2000 120
100
80
60
20
40
(55)
(45)
(36)
(27)
(9)
(18)
140
117
23
47
(64)
(53)
(11)
(21)
160
133
27
53
(73)
(61)
(12)
(24)
180
150
30
60
(82)
(68)
(14)
(27)
200
167
33
67
(91)
(76)
(15)
(30)
220
183
37
73
(100)
(83)
(17)
(33)
240
200
40
80
(109)
(91)
(18)
(36)
70
(32)
80
(36)
90
(41)
100
(45)
110
(50)
120
(55)
93
(42)
107
(48)
120
(55)
133
(61)
147
(67)
160
(73)
2200
3000
2800
2400
3200 Ideal Ideal Ideal Ideal Ideal Ideal Ideal
2600
above 3400 Dilute Dilute Dilute Dilute Dilute Dilute Dilute
POUNDS and (Kg) OF SALT NEEDED FOR 3200 PPM
Other manuals for Salt & Swim
2
Other Hayward Other manuals