Hayward HLWALLMOUNT User manual

Hayward Pool Products
620 Division Street, Elizabeth NJ 07207
www.hayward.com
Wired Wall Mount Terminal
Touchscreen Terminal for OmniLogic
Owner's Manual
HLWALLMOUNT
Contents
Description............................2
Installation............................3
Conguration.........................6
Operation..............................6
092523 RevA
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

FCC Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Hayward could void the user’s authority to
operate this equipment.
NOTE:This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio
or television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-- Consult the dealer or an experienced radio / TV technician for help.
Industry Canada Statement
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
The term “IC” before the certification / registration number only signifies that the Industry Canada
technical specifications were met.
1
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Description
The HLWALLMOUNT is a remote touchscreen terminal that wires directly to the OmniLogic pool
automation controller. It is designed to fasten to a wall giving the user convenient access for
monitoring and controlling their pool. Up to two HLWALLMOUNTs can be installed and connected
to the OmniLogic. After installation, the OmniLogic will detect the new HLWALLMOUNT(s) and
automatically configure itself to utilize the new terminal(s).
Compatibility
The HLWALLMOUNT is compatible with all OmniLogic pool controls.
Before You Begin
Included:
• HLWALLMOUNT Remote Terminal
What you'll need:
• mounting screws/anchors
• an appropriate length of 4 conductor, 20 - 24AWG twisted pair wire (CAT3 or better pre-
ferred but not mandatory) for connecting the HLWALLMOUNT to the OmniLogic
• wirecutter/wirestripper
• tools for mounting, small flathead screwdriver for screw terminals
The HLWALLMOUNT must be mounted indoors or in a weather protected area (rain should never
be in contact with the touchscreen).
When considering a potential mounting location, survey the wiring route from the OmniLogic to
the HLWALLMOUNT. Ensure that you can successfully run an uninterrupted length of 4 conduc-
tor wire. Although various types of wire can be used, 4 conductor, solid 22AWG phone cable
is recommended. Refer to the table below for limitations on wire run lengths. When selecting
a location, note that the connecting the OmniLogic to the HLWALLMOUNT must not exceed the
recommended lengths shown in the chart below.
Up to two HLWALLMOUNTs can be wired to the OmniLogic. If wired in parallel, both units can
be wired up to the maximum distance shown below. If daisy chained, the furthest unit can not
exceed the maximum distance shown below.
20 AWG 22AWG 24AWG
Maximum Distance 450ft / 140m 285ft / 85m 180ft / 55m
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
2

Installation
DANGER of Death, Injury or Property Damage if procedure not followed. This accessory
connects to the OmniLogic panel beneath the dead front. Dead front removal is required for this
installation. Power to the OmniLogic panel MUST be shut off before the dead front is removed.
This means a complete shutdown of power to the entire OmniLogic panel.
Remove power to the OmniLogic. Remove the OmniLogic cover panel (dead front) to expose the
main board and internal relays.
Mounting
1. Remove the remote terminal wallplate from the cover by inserting a screwdriver in the slot shown
below. Lift up on the cover while pushing gently with the screwdriver.
Push Screwdriver
blade through slot
and pull up cover
3
USE ONLY HAYWARD GENUINE REPLACEMENT PARTSUSE ONLY HAYWARD GENUINE REPLACEMENT PARTS

2. Fasten the wallplate at the desired location (screws supplied by installer).
Wiring
Use four conductor cable (typically phone cable) to connect the remote display keypad with the
OmniLogic Main Board as shown below. Refer to the chart on page 1 for maximum wire length.
For a clean "cable free" look, route the cable so that it exits the mounting surface and enters
through the access hole in the wallplate.
Connect the cable to the high speed RS-485 screw terminals on the OmniLogic and HLWALL-
MOUNT as shown below. The screw terminals are numbered on both units. Connect 1 to 1, 2 to
2, etc. Screw terminal #5 is not used on the OmniLogic.
Up to two HLWALLMOUNTs can be installed in parallel or daisy chained. In both cases, never con-
nect more than two wires to any terminal block.
Parallel: Two HLWALLMOUNTs are wired back to the OmniLogic main unit (connection made at
OmniLogic) and both can be at the maximum distance.
Wall plate mounting holes
Access hole
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

Daisy Chain: The second (furthest) HLWALLMOUNT is wired to the first (connection made at first
HLWALLMOUNT) and the second HLWALLMOUNT must not exceed the maximum distance from
OmniLogic. Connect 1 to 1, 2 to 2, etc.
After wiring is complete, reinstall the HLWALLMOUNT cover. Reinstall the OmniLogic dead front
and restore power to the OmniLogic.
Remote Terminal
Refer to Table for
maximum distance
1
2
3
4
OmniLogic Main Board
Connect screw terminals
“1” to “1”, “2” to “2”, etc.
1
2
3
4
5
Pin 5
not used
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
5

SYSTEM
configuration
msp id:3233
component HUA version
MSP
MP
Relays
Wired Wall Mou...
EcoStar pump
0-0-0-0
1-65-0-2a-d4
3-10-0-0-1
31-2-0-0-b1
10-0-0-0-54
X.1.0.118-b14005
R.1.0.2
R.1.0.2
R.3.0.4
B1.0.16
POOL
configuration
firmware upgrade
restore config
config wizard
display
web server
backup config
wired networking
system info
favorites
config
heating
themes
ºF
daylight
features
alarm
lights
ºF
Configuration
When the OmniLogic first starts HLWALLMOUNT should automatically be discovered and configured.
No input is required from the user. To verify that the OmniLogic has discovered the HLWALLMOUNT,
go to the local terminal (touchscreen on the OmniLogic) and follow the procedure below. There should
be a line entry showing the HUA and version.
Operation
The HLWALLMOUNT provides the same functionality as the Local Terminal except for the following:
• No Service Mode - Service mode is only accessible from the Local Terminal
• Limited Configuration options - Full access to all OmniLogic configuration settings is only
available at the Local Terminal.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
6

For further information or consumer
technical support, visit our website at
www.hayward.com
Hayward is a registered trademark and OmniLogic is
a trademark of Hayward Industries, Inc. © 2013 Hayward Industries, Inc.
All other trademarks not owned by Hayward are the property of their respective owners.
Hayward is not in any way affiliated with or endorsed by those third parties.
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Table of contents
Other Hayward Touch Terminal manuals