HealthTeam Paraffin Heat System PA2293 User manual

PA2293-INS-LAB-RevB08
The HealthTeam Parafn Heat System is designed to:
• Provide heat therapy to soothe the pain caused by arthritis, joint
stiffness and muscle spasms.
• Condition and moisturize coarse, dry hands, feet and elbows.
IMPORTANT: Please read instructions before use
Model PA2293

2
CONTENTS
IMPORTANT SAFETY GUIDELINES – PLEASE READ BEFORE USE ...................................3
HEALTHTEAM PARAFFIN HEAT SYSTEM OPERATION.........................................................6
FILLING THE PARAFFIN HEAT SYSTEM..........................................................................6
HEATING SYSTEM OVERVIEW .........................................................................................7
USING THE PARAFFIN HEATING SYSTEM: FOR HANDS, FEET, OR ELBOWS ...........7
CLEANING THE UNIT AND REPLACING WAX ......................................................................10
WARRANTY..............................................................................................................................11
GF, Graham-Field, and HealthTeam are registered trademarks of
GF Health Products, Inc.
Packaging, warranties and products are subject to change without notice.
GF Health Products, Inc. is not responsible for typographical errors.

3
PA2293: HEALTHTEAM PArAffin HEAT SySTEM
PLEASE SAVE THESE inSTrUCTiOnS fOr fUTUrE USE
Congratulations! You have just purchased a HealthTeam Paraffin
Heat System from Graham-Field Health Products. Please read the
following information carefully as it is designed to help provide opti-
mum heat therapy.
iMPOrTAnT SAfETy GUiDELinES – PLEASE rEAD BEfOrE USE
WARNING: Do not use this product without proper instruction
from a Healthcare Professional.
WARNING: Read and understand all instructions before using the
HealthTeam Parafn Heat System. Failure to use as instructed
could result in personal injury and/or damage to the Parafn Heat
System.

4
WARNING: GF Health Products, Inc. assumes no responsibility for
any damage or injury caused by improper installation, assembly
or use of this product.
WARNING: Always unplug the unit from the electrical outlet imme-
diately after using.
WARNING: Do not operate this product if it has a damaged cord
or plug.
WARNING: This device is equipped with a three-prong (ground-
ing) plug for protection against possible shock hazard. Plug only
into a properly grounded three-prong wall receptacle.
WARNING: Always place this unit in a location where the electri-
cal cord will not be stepped on, tripped over, or otherwise sub-
jected to damage or stress. Do not use this unit with an extension
cord.

5
WARNING: Do not use, store or place this unit where it could fall
or be pulled into water.
WARNING: If the unit accidentally falls into water or any liquid, DO
NOT TOUCH; unplug immediately!
WARNING: Use the HealthTeam Parafn Heat System on a level
surface.
WARNING: Avoid applying hot parafn wax near eyes, heat sensi-
tive areas, or any open skin injury.
WARNING: Allow the appliance to cool completely before han-
dling, cleaning or storing.
WARNING: Do not plug or unplug this appliance when hands or
body are wet.
WARNING: Do not heat parafn wax in microwave, stove or using
any method other than the HealthTeam Parafn Heat System.

6
HEALTHTEAM PArAffin HEAT SySTEM OPErATiOn
Filling the Parafn Heat System
1. Ensure that the unit is on a level, at, sturdy, heat resistant sur-
face.
2. Remove the lid and all plastic packaging inside the unit.
3. Open the one lb. parafn wax pellets or blocks and place half
of the contents in the unit. Add the remaining when these have
melted. Do not overll the unit. Do not ll the system past the
maximum ll line indicated.
4. Plug the unit into a properly grounded, 120 volt, 60 cycle single
phase power outlet. The red light will illuminate to indicate that
power is being transferred to the unit and that the system is in
the ON position.
5. Place the lid back onto the unit to retain heat.

7
6. It will take approximately 50 - 60 minutes to see the wax begin
to melt. To melt six pounds of wax requires approximately 4 - 6
hours.
Heating System Overview
The illuminated light indicates the unit is on and operating. The
heating element of this unit heats the parafn wax to approximately
122 - 131 degrees Fahrenheit and will shut off automatically if the
thermostat malfunctions.
Using the Parafn Heating System: For Hands, Feet, or Elbows
1. Remove all jewelry. Wash and dry hands, feet or elbows thor-
oughly.
2. Remove lid from the unit. Test the temperature of the wax by
lightly touching the melted wax with the inside of the wrist. DO
NOT place any part of the body into the wax if the wax is too hot
when tested on the inside of the wrist. If the temperature is too

8
hot, contact your Graham-Field equip-
ment provider for assistance.
3. If the temperature of the wax was ac-
ceptable when tested on the inside of
the wrist, place the desired hand, elbow
or foot into the wax. For hands, start by
opening the desired hand and spreading
the ngers apart as shown in the picture
at above right. Slowly immerse the hand,
foot or elbow into the parafn wax and
then immediately remove it. Wait 3-5
seconds and re-dip. Waiting 3-5 seconds
allows the parafn wax to set. Repeat this
process two or three times to create more
wax layers. The parafn usually takes
12 - 15 minutes to completely harden.

9
WARNING: Use with caution if skin is sensitive. Discontinue use
immediately if any pain, irritation or discomfort is experienced.
Note: To retain heat, place the hand or foot which has been immersed
in a plastic liner and cover with the bootie or mitt provided, shown at
right, for fifteen minutes for longer to obtain
the desired heat therapy.
4. After heat therapy is nished, peel the
hardened wax from the hand, elbow or
foot. For hand: begin with the wrist and
work in a downward motion, removing all
of the parafn wax. Make sure that all of
the wax is removed.
5. To maintain softness, massage oil or
lotion of your choice onto the hands,
elbows or feet.
hand mitt
foot bootie

10
6. Discard the hard wax as it may contain cell build-up from the
skin. DO NOT PUT PARAFFIN RESIDUE BACK INTO THE UNIT.
CLEAninG THE UniT AnD rEPLACinG WAX
Clean the unit when the parafn wax becomes dry or discolored, or
when there is a build-up of skin on the bottom of the unit.
1. Unplug the unit. Allow the parafn to solidify, which can take sev-
eral hours.
2. After the parafn is solid, plug the unit in for a few minutes to
loosen the wax from the bottom and sides of the unit. Then un-
plug the unit.
WARNING: Do not leave the unit plugged in; it could get exces-
sively hot and result in personal injury and/or damage to the unit.
3. Remove the parafn and wipe the inside of the unit with a paper
towel.

11
4. Make sure that the unit is unplugged and cool before cleaning.
Clean the unit with an all-purpose cleaner (DO NOT USE CHLO-
RINE OR BLEACH) and wipe dry.
5. The unit is then ready for new parafn wax for next use. Store the
Parafn Heat System in a cool, dry place. *
* Paraffin wax beads available: Item # 2294 Wintergreen and Item # 2295 Unscented
WArrAnTy
GF Health Products, Inc. warrants the HealthTeam Model PA2293 Par-
afn Heat System for a period of six months for defects in workman-
ship and materials. During the warranty period, defective items will
be repaired or replaced at manufacturer's option at no charge.

USA, Corporate Headquarters:
Graham-Field Health Products
2935 Northeast Parkway
Atlanta, Georgia 30360
tel: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
www.grahamfield.com
© 2008 GF Health Products, Inc.
PA2293-INS-LAB-RevB08

PA2293-INS-LAB-RevB08
El Sistema de Parana Caliente de HealthTeam es diseñado para:
• Suministrar terapia caliente para aliviar el dolor causado por artri-
tis, rigidez de las junturas y espasmo de los músculos.
• Acondicionar y hidratar las manos, los pies y los codos.
Por Favor de Leer las Instrucciones Antes de Uso
Sistema de Parafina
Caliente de HealthTeam®
INSTRUCCIONES DE USO

2
GF, Graham-Field y HealthTeam son marcas registradas de
GF Health Products, Inc.
El envasado, garantías y productos son subjetivos a cambiar sin aviso. GF Health
Products, Inc. no es responsable para errores tipográcos.
CONTENIDOS
DIRECTIVAS IMPORTANTE DE SEGURIDAD – LEA ANTES DE USO...................................3
OPERACIÓN DEL SISTEMA DE PARAFINA CALIENTE..........................................................6
LLENANDO EL SISTEMA DE PARAFINA..........................................................................6
CALENTANDO EL SISTEMA .............................................................................................7
PARA LAS MANOS.............................................................................................................7
PARA LOS PIES Y LOS CODOS........................................................................................9
LIMPIANDO EL SISTEMA Y CAMBIANDO LA CERA...............................................................9
GARANTÍA................................................................................................................................11

3
PA2293: SiSTEMA DE PArAfinA CALiEnTE DE HEALTHTEAM
GUArDE ESTAS inSTrUCCiOnES PArA USO En EL fUTUrO
Felicitaciones! Usted ha comprado un Sistema de Parafina Caliente de
HealthTeam de Graham-Field Health Products. Por favor de leer las si-
guientes instrucciones cuidadosamente porque son diseñado a ayudar
para suministrar terapia caliente óptimo.
DirECTiVAS iMPOrTAnTE DE SEGUriDAD – LEA AnTES DE USO
AVISO: No debe usar este producto sin instrucciones correctos de
un Profesional de Cuido de Salud.
AVISO: Lea y entienda todas las instrucciones antes de usar el Siste-
ma de Parana Caliente de HealthTeam. Fallo de usar como indicado
puede resultar en lesión personal y/o daño al Sistema de Parana
Caliente.

4
AVISO: GF Health Products, Inc. no asume ninguna responsabilidad
de daño o lesión causado por instalación, asamblea o uso impropio
de este producto.
AVISO: Siempre debe desenchufar el sistema del toma eléctrico in-
mediatamente después de uso.
AVISO: No debe operar este producto si tiene un cordón o enchufe
dañado.
AVISO: Este aparato es equipado con un enchufe de tres-puntas
para protección contra calambre peligrosos. Enchufe solamente en
un enchufe de pared correcto.
AVISO: Pon el sistema donde el cordón eléctrico no puede ser pi-
sado, tropezado en o subjetivo a daño y tensión. No debe usar este
sistema con un cordón con extensión.
AVISO: No use, guarde o ponga el sistema donde se puede caer en
agua.

5
AVISO: Si el sistema se cae en agua o cualquier liquido, NO LO TO-
QUES, Enchufe inmediatamente!
AVISO: Use el Sistema de Parana Caliente en un supercie nivel.
AVISO: Evite aplicar la cera caliente de parana cerca de sus ojos,
en otras áreas sensitivas o donde tiene un lesión abierta en la piel.
AVISO: Permite que el sistema se enfríe completamente antes de
limpiar o guardarlo.
AVISO: No debe enchufar o desenchufar el sistema cuando tiene las
manos o el cuerpo mojado.
AVISO: No debe calentar la cera de parana en el microonda, la estu-
fa, o cualquier otro método aparte del Sistema de Parana Caliente
de HealthTeam.

6
OPErACión DEL SiSTEMA DE PArAfinA CALiEnTE
Llenando el Sistema de Parana
1. Asegure que el sistema está en un supercie nivel y resistente al
calor.
2. Retire la tapa y todo el embalaje plástico adentro del sistema.
3. Abre la bolsa de 1 libra de cera y utilice la mitad de los contenidos
en el sistema. Añade lo restante después cuando ha derretido.
4. Enchufe el sistema en el enchufe de pared correcto de 120 voltio,
fase de 60 ciclos; la luz se iluminara.
5. Ponga la tapa en el sistema para retener calor.
6. Va tomar aproximadamente 50-60 minutos para que la cera empieza
a derretir. Para derretir seis libras de cera requerirá aproximada-
mente 4-6 horas.

7
Calentando el Sistema
La luz iluminada indica que el sistema está prendido y funcione. El
elemento que calienta el sistema caliente la cera a aproximadamente
122 - 131 grados de Fahrenheit y se apaga solo automáticamente si el
termostato no funcione.
Para Las Manos
1. Retire su joyería. Lave y seca sus manos
completamente.
2. Retire la tapa del sistema y cuidadosa-
mente pruebe la temperatura de la cera
usando la parte de adentro de su muñeca.
3. Abre su mano y extiende sus dedos y
sumergiré su mano lentamente en la cera
de parana (como se enseña en la foto a
la derecha).

8
Con cuidado, inmediatamente retire su mano. Esto permite que la
parana se queda en su mano. Repite este proceso tres o cuatro
veces para crear más capas de cera. La parana usualmente toma
12-15 minutos para ponerse duro completamente.
AVISO: Usa con precaución si la piel es
sensitiva. Interrumpir el uso inmediatamen-
te si experiencia dolor, irritación o incomo-
didad.
Nota: Para retener el calor, cubre su mano con
una funda de plástico y cubre la mano con el
manopla de mano proveído por 15 minutos
para prolongar la terapia con calor (o Para los
Pies: El calcetín enseñado en la bajo derecha).
el manopla de mano
el calcetín
Table of contents
Languages: