manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. HealthWay
  6. •
  7. Air Cleaner
  8. •
  9. HealthWay NR-20600-3NR User manual

HealthWay NR-20600-3NR User manual

Warranty Claims Procedure:
The validity of a product claim under this Limited Warranty depends upon your
following these simple steps. To make a product claim, please follow steps A-E:
A. For Service Questions Call (CWR’s) Customer Service toll-free
at 1-800-444-3563.
B. Obtain Return Authorization Number: Call CWR Customer Service toll-free
at 1-800-444-3563 to obtain a Return Authorization Number for your unit.
C. Packaging and Shipping: Carefully pack the product in its original carton with original
packaging materials to avoid damage in shipping. (If you no longer have the original
box, one can be supplied for a nominal cost). For convenience in tracking your
shipment, CWR recommends that you ship the unit by United Parcel Service (UPS).
ALL OUTBOUND AND RETURN WARRANTY PRODUCT SHIPPING CHARGES
MUST BE PREPAID BY YOU. Please insure the product for the original pur-
chase price. CWR cannot accept freight collect shipments.
D. Assemble and Enclose Information: Enclose the following information in an
envelope and tape the envelope to the unit itself:
(1) Your Return Authorization Number
(2) Your name, complete address with zip code, and telephone number
(3) A dated sales receipt or dated Proof of Purchase; and
(4) A short specific description of the malfunction
E. Ship the Product Prepaid to:
Place Return Authorization # on outside of box.
This Shipping Address and the Return Authorization Number must,
without exception, appear on the outside of the shipping carton, or your
return may be refused.
©2011, Clean Water Revival, Inc.
Model # NR-20600-3NR + Remote
with patented
EGF (Enhanced Germicidal Filtration)
Operations Manual
Return your Warranty Registration card today to
ensure you receive all the benefits you’re entitled to.
Once your Healthway purchase is registered, you’re entitled
to receive all the privelges of owning a Healthway product.
So complete and return the Warranty Registration card en-
closed with your purchase at once and take advantage of
these important benefits.
Warranty Verification:
Registering your product promptly qualifies your unit for
warranty service under the terms and conditions of your
HealthWay AIr PurifierTM warranty.
Owner Confirmation:
Your completed Warranty Registration Card serves as
verification of ownership in the event of product theft or loss.
Model Registration:
Returning your Warranty Registration Card promptly
guarantees you’ll receive all the information and special
offers which you qualify for as the owner of your model.
Distributed by:
Clean Water Revival Inc.
dba CWR, Environmental Products
7897 SW Jack James Drive, Ste C, Stuart, FL 34997
Telephone: 1-800-444-3563
Website: www.cwrenviro.com
j/dw/w/Bio-Net/2013 healthway instructions
HealthWay
Portable Room AIr Cleaner
T Your HealthWay AIr PurifierTMhas been carefully packed to avoid
damage during shipment. Remove all packing material from the unit
and locate the four castors in the packing material, these castors
need to be placed under the unit for easy gliding. (See Instructions)
Save all packing and shipping material in case of a service issue.
T Please inspect the unit to insure that you receive the product free
of any visible sign of damage. Do not operate this unit with a damaged
cord or plug. If you detect any damage to your unit, call our Service
Dept. immediately (within 5 days of receipt of unit) at
1-800-444-3563 for damage claim procedures.
T Select a desired location to place the unit, near an electrical outlet.
Place the unit at least 6 inches away from the wall and face the unit
towards the room for maximum air exchange. For best air cleaning run
the unit 24 hours/day.
Warning: This air purifier must be plugged into a 120 Volt, AC earth grounded outlet.
Do not use this air purifier with a wall outlet adapter. Do not operate this air purifier
with an extension cord. To prevent fire or shock, do not expose unit to rain or
moisture.
1. Plug the unit DIRECTLYinto an earth grounded standard 120 volt,
AC electrical outlet. The plug is a polarized line plug (one blade is
wider than the other) and can only be inserted one way as a safety
feature.
2. Place the unit on a flat and level surface to allow continuous
airflow to the bottom intake and out the top outlet grill.
3. Always unplug the air purifier before moving it, opening the top lid,
changing the main filter or before cleaning. (Clean only with a dry,
non-static cloth.) Do not operate this unit with an extension cord.
4. Do not place any foreign objects inside the unit because electric
shock and injury could result.
5. Do not operate the unit if any part is missing or damaged.
6. Do not run the power cord under carpeting or near heaters,
registers, radiators, stoves or fireplaces. To avoid a tripping
hazard, keep the power cord away from traffic areas.
7. Never operate the air purifier in an area where combustible gases
or vapors are present or any other flammable materials.
8. Never immerse the unit in water or other liquids. Do not spray the
air purifier with liquids or clean the air purifier under running water.
9. This unit is designed for indoor use only. This unit is designed for resi-
dential or light commerical use. Do not use in heavy commercial applications.
Limited Warranty:
This Limited 2-Year Warranty applies only to the repair or replacement of any
manufactured or supplied part of this product which, upon inspection by a
HealthWay® authorized service center, proves to have failed in normal use due
to defects in material or workmanship. The sole responsibility of HealthWay®
under this Limited Warranty is, in its sole discretion, to either repair or replace
a duly registered product (or defective part thereof) with the same or a compa-
rable model within a reasonable period of time, subject to the following exclu-
sions, limitations, statutory rights, and warranty claim procedures. This Limited
Warranty is exclusive, and HealthWay® expressly disclaims all other or addi-
tional warranties, whether written or oral, expressed or implied, including, but
not limited to, warranties of merchantability, workmanship, or fitness for a par-
ticular purpose.
Exclusions:
A. This Limited Warranty does not apply, or is void, as to any product or part
damaged by (1) accident, misuse, abuse, or lack of reasonable care or normal
maintenance, including not replacing filters according to Replacement Sched-
ule; (2) installation or operation under conditions other than those recommended
by HealthWay® ; (3) subjecting the product to any but the specified voltage; (4)
servicing or disassembly by unauthorized personnel; (5) removing or defacing
the serial number; or (6) modifying the original factory-assembled unit in any
way.
B. This Limited Warranty does not apply to shipping charges (customer will
be responsible for shipping charges) for product shipped to or from the
factory or designated service center in connection with warranty claims nor
does it apply to any damages occurring during such shipment.
C. This Limited Warranty does not apply to installation, removal, reinstallation,
and/or related expenses. This Limited Warranty does not apply to replaceable
filters.
Limitations:
HealthWay® shall not be liable for property, incidental, and/or consequential
damages of any kind and, unless otherwise prescribed by applicable state law,
HealthWay® shall not be liable for personal injury resulting from malfunctions,
defects, misuse, improper operation or installation, or alteration of a HealthWay®
product or any part thereof. The exclusive remedy for a breach of this Limited
Warranty is the repair or replacement of the defective product. In no case, shall
liability under any other remedy prescribed by law exceed the purchase price of
the product.
Statutory Rights:
This Limited Warranty, subject to the above exclusions and limitations, gives
you specific legal rights in addition to statutory rights you may have under
applicable state law. Some states, however, do not permit the limitation or
exclusion of incidental or consequential damages, so such limitation may not
apply to you. To the extent that any provision of this Limited Warranty is incon-
sistent with applicable law, such provision shall be deemed void or amended,
as necessary, to comply with such law.
Important Safety Precautions
Please read all instructions before operating your air purifier. Basic precautions
should always be observed when using electrical appliances to reduce the risk of fire,
shock and/or injury. Observe the following general precautions to insure effective, safe
and trouble-free operation of your HealthWay AIr Purifier.TM
Easy Set Up Instructions for the HealthWay AIr PurifierTM
HealthWay® offers a two-year limited warranty on all consumer
products.
1) Retain proof of purchase and the original box and
packaging materials.
2) Mail Warranty Registration Card to CWR within 10 days
of date of original purchase. OR
3) Fax Warranty Registration Card within 10 days of date
of original purchase. (Fax # 1-561-799-7943)
4) To make a product claim, call 1-800-444-3563
to obtain a warranty claim number.
5) Website Warranty Registration-
www.cwrenviro.com/warranty.htm
Product Registration:
HealthWay® makes this Two (2) Year Limited Warranty
(“Limited Warranty”) ONLYto the original retail purchaser who
completes the enclosed Warranty Registration Card within ten
(10) days of purchase and faxes it to: (1-561-799-7943); or mail it
to:
Clean Water Revival, Inc.
dba, CWR, Environmental Products
7897 SW Jack James Drive, Ste C, Stuart, FL 34997
Electronic Control Panel
Service Light - indicates when unit
requres service.
Bio-Monitor Light - Shows EMFTM Germ
killing zone is working at peak efficiency.
Convenient three speed control.
Low Speed - Ultra-Quiet Air flow mode.
Revolutionary FDA listed
ELUDEHCSTNEMECALPER ELUDEHCSTNEMECALPER ELUDEHCSTNEMECALPER ELUDEHCSTNEMECALPER ELUDEHCSTNEMECALPER
noitpircseD #metI eludehcS
NIAM
RETLIF NFGEFR-NB SHTNOM21**
RETLIF-ERP ZBRACFR-NB
SHTNOM21**
erayarTretliF-erPehT
dnaelbanaelcmuucav
elbisrever
T NOTE: **The chart above shows only estimates of the life of the filters. Fre-
quency of filter changes will vary depending on the amount of contaminants in your
indoor environment.
EDIUGGNITOOHSELBUORT
MOTPMYS YDEMER/KCEHC
NOnruttonlliwtinU *021"gnikrow"aotnideggulptinuehtsI
?teltuodednuorghtrae,CA,tloV
*dnaecalpnirevocpots'tinuehtsI
.ngilaerdnaevomeR?tuhsdeppans
*htiw,ecalpnidekcolretliFniaMehtsI
gnicafeldnahgnikcolretliFniaMeht
evomeR?tinuehtforetnecehtdrawot
.ngilaerdna
NOnruttonllitslliwtinU ecivreSremotsuCllaC
ontub,NOsitinU
egnahCdeeps ecivreSremotsuCllaC
tuoseogretliFniaM *retliFniaMecalpeR
*mumixamstidehcaersahretliFniaM
.yticapacgnidlohtnanimatnoc
FFOsithgilrotinoMoiB tifI.nosithgiLnoticnuFSFDerusekaM
ecivreSremotsuCllaCnonrutt'nseod
esioNgnilkcarC *selcitraprotsudevahyamseriWFGE
evomerotspetsehtwolloF.mehtno
retliFniaMFGE )D.gifees( yltneG.
bawslohoclahtiwseriwFGEehtepiw
evomerotnacriadesserpmocaesuro
.retliFniaMehtecalpeR.tsudeht
The new standard in clean air!
100% Sealed Filtration Chamber
All incoming air is treated in the 100%
sealed filter chamber.
l
l
l
l
GERM KILLING ZONE!
99-100% of viruses
98-100% of bacteria
94-100% of mold & fungi
l
l
l
Dual Air Intake Blower
Drives a consistent volume of air and
provides ultra-quiet operation.
Reversible Multi-Stage Filtration
4 Stage Filter
Provides particulate prefiltering and multiple
gas/chemical scrubbing.
Dual Pre-Filters are cleanable and reversible for
extra particle reduction.
Carbon/Zeolite media for gas, odor and
chemical reduction.
3600 Degree Air Intake
Allows placement anywhere
ensuring all room air is treated
Reversible
Multi-Stage Filtration
10 micron Pre-Filter
Zeolite
Honeycomb Activated Carbon
10 micron Pre-Filter
l
l
l
EGFTM Filter
Better than 99.99% particle reduction at 0.3
microns. 4x the particle capture as a similar
size HEPAfitler. Traps microorganisms for
germicidal exposure.
l
l
l
l
HealthWayAir PurifierTM
HealthWay AIr PurifierTM Operation:
Plug the unit into a standard 120 volt earth grounded AC circuit and press either
the speed button on the control panal or the remote to the desired setting. The
control panel lights should be illuminated as follows:
Main Filter - green light is ON (Functioning)
Pre-Filter - green light is ON (Functioning)
Bio Monitor DFS - green light is ON (Functioning)
When the unit is operating properly, all three indicator lights will be “green”.
Main Filter Service Light: When the Main Filter Function light goes OFF -
this indicates that you have to replace the Main Filter and clean the wires.
The average life expectancy is 12 months. See Main Filter “cange” instruc-
tions. (Fig A-E)
Bio Monitor - (DFS) Light: Green light ON indicates that airborne microor-
ganisms are continuously being inactivated in the Filtration Grid System. If
the light goes OFF, microorganism inactivation has been interrupted. Immedi-
ately turn off the unit and unplug it from the outlet. Call CWR customer
service at 1-800-444-3563 NOTE: Never shutt off DFS function.
The remote control is located in the shipping box on top of the air purifier.
When using the remote make sure you aim the remote control towards the
control panel sensor. The remote will work up to 12 feet. To start the unit
press the desired setting, Low/Medium/High. To shut OFF unit, press the
OFF button. The battery is included (Lithium 3 Volt- CR 2025).
Pre-Filter Funciton Light: (Fig F-H) This is a warning light that will go OFF
in 6 months and the Pre-Filter is overdue for cleaning. Normally the Pre-filter
should be vacuumed at least once a month and reversed. Before cleaning the
unit, shut the air purifier OFF and unplug it from the outlet. Remove the 7-
Stage Pre-Filter, gently vacuum both sides of the filter. Reverse and reinsert
into filter drawer.
***NOTE: People with chemical and environmental (MCS) sensitivities will
detect contaminants at lower levels and will have to change filters sooner.
People with pets or who live in very polluted areas, will need to clean and
change filters more frequently.
1.Turn the air purifier off and unplug from power outlet.
2.To access Main Filter, place fingertips under side re-
cesses of black cover, gently pull outward and lift cover
up to remove. Separate cover from the air purifier.
(Fig. A)
Pre-Filter Change/Cleaning Instructions:
4.To remove Main Filter, lift filter
from the internal chamber. (Fig. C).
(To Clean- gently wipe the wires
with alcohol swab or use com-
pressed air can to remove dust.)
Before installing the new Main Fil-
ter, make sure the black filter seal
“O” ring is seated properly in the
“O” ring channel (Fig.D). The EGF
Filter is labeled with “FRONT” this
must be positioned to the front
of the unit. (Fig.C)
(Fig. C)
(Fig. B)(Fig. A)
(Fig. D) (Fig. E)
Control Panel Guide
3. To release Main Filter, move both
black handles 90° toward front of air
purifier. (Fig.B). Do not force the
handles.
To Change Main Filter:
(Fig. F) (Fig. G)
1. Turn the air purifier off and unplug from power outlet. To change/vacuum Carbon Filter, Open
back panel (Fig.F) remove panel and set it down. Pull out Carbon Tray (Fig.G) and replace
every 12 months. If your have high levels of particulates in your home and/or animal hair you
can easily vacuum the Pre-Filters, between filter changes, which are located on the underside
of the Carbon Tray, see (Fig.H). Simply vacuum the Carbon Tray Pre-filter. Then turn the tray
over and reinsert into filter drawer. This procedure can be repeated as necessary, however, it is
highly recommended that this entire filter be replaced annually.
2. Reattach back panel. Your unit is now ready for use.
(Fig. H)
for Pre-filtration tray
6.To replace the lid, align the 2 vertical tabs, on the inside of the lid, with the slots in the top of the
machine. Push down gently and snap shut. Plug air purifier into power outlet and turn on. (Fig. A)
Note: The unit will not run with top attached improperly.
5.To load Main Filter, align hole in filter tab with brass contact (Fig.E). Press filter down.
To lock filter in place, move both black handles in 90° toward the center of the filter.
CAUTION: Do not force handles, they should move freely, if not, realign filter.
Remote Control
Remote sensor

Other HealthWay Air Cleaner manuals

HealthWay Delos Intellipure 950P User manual

HealthWay

HealthWay Delos Intellipure 950P User manual

HealthWay 20600-3 Deluxe User manual

HealthWay

HealthWay 20600-3 Deluxe User manual

HealthWay 2000ILP User manual

HealthWay

HealthWay 2000ILP User manual

HealthWay SuperV Series User manual

HealthWay

HealthWay SuperV Series User manual

HealthWay 1200SC Series User manual

HealthWay

HealthWay 1200SC Series User manual

Popular Air Cleaner manuals by other brands

Vortice VORTRONIC 35 RF Instruction booklet

Vortice

Vortice VORTRONIC 35 RF Instruction booklet

Hunter QuietFlo 30401 owner's manual

Hunter

Hunter QuietFlo 30401 owner's manual

MANN+HUMMEL OurAir SQ 500 Original operating manual

MANN+HUMMEL

MANN+HUMMEL OurAir SQ 500 Original operating manual

Insignia NS-AP16BK8 user guide

Insignia

Insignia NS-AP16BK8 user guide

CLEANAIRE CAHP-50 02 Series instruction manual

CLEANAIRE

CLEANAIRE CAHP-50 02 Series instruction manual

AtmosAir FC-400 Series Installation, operation and maintenance guide

AtmosAir

AtmosAir FC-400 Series Installation, operation and maintenance guide

Atten ST-1016 user manual

Atten

Atten ST-1016 user manual

Rowenta PURE AIR ESSENTIAL PU2530 manual

Rowenta

Rowenta PURE AIR ESSENTIAL PU2530 manual

Heaven Fresh HF 60 instruction manual

Heaven Fresh

Heaven Fresh HF 60 instruction manual

Bosch B1 RKM 09004 Instructions for use

Bosch

Bosch B1 RKM 09004 Instructions for use

Kogan SmarterHome 1S user guide

Kogan

Kogan SmarterHome 1S user guide

Panasonic Nanoe X F-PXU70M operating instructions

Panasonic

Panasonic Nanoe X F-PXU70M operating instructions

Enviroflex ENVIROMAC MAC1 owner's manual

Enviroflex

Enviroflex ENVIROMAC MAC1 owner's manual

HoMedics AF-75 Instruction manual and  warranty information

HoMedics

HoMedics AF-75 Instruction manual and warranty information

NuWave OXYPURE 47001 quick start guide

NuWave

NuWave OXYPURE 47001 quick start guide

grovpure aspen user manual

grovpure

grovpure aspen user manual

Rowenta PURE AIR ESSENTIAL PU2532 manual

Rowenta

Rowenta PURE AIR ESSENTIAL PU2532 manual

Holmes HAP116 owner's guide

Holmes

Holmes HAP116 owner's guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.