SPECIFICATIONS
Range........................... Upto70ft.(21m);100ft.(30.5m)withRangeBoost.[varieswithsurroundingtemperature]
Sensing Angle.............. Upto110°
ElectricalLoad.............. Upto200WattMaximumIncandescent[Upto100Wattmaximumeachlampholder]
PowerRequirements.... 120VAC,60Hz
Operating Modes.......... TEST,AUTOandMANUALMODE
LampModes................. Security,BulbSaver,AlertFlash
TimeDelay................... 1,5,20minutes
DualBrite®Timer.......... Off,3,6hours,Dusk-to-Dawn
Replacementlamp........ T4100W,G8halogenbi-pin120VAC
SYMPTOM POSSIBLE CAUSE SOLUTION
Lightwillnotcomeon. 1. Lightswitchisturnedoff.
2. Lampislooseorburnedout.
3. Fuseisblownorcircuitbreakeristurnedoff.
4. Daylightturn-offisineffect.
5. Incorrectcircuitwiring,ifthisisanewinstallation.
6. Sensordoesnotdetectobjectsindesiredarea.
1. Turnlightswitchon.
2. Checklampandreplaceifburnedout.
3. Replacefuseorturncircuitbreakeron.
4. Recheckafterdark.
5. Verifywiringiscorrect.
6. Re-aimsensortocoverdesiredarea.Increasesen-
sitivity.
Lightcomesoninday-
light.
1. Light control may be installed in a relatively dark
location.
2. LightcontrolisinTEST.
1. Relocate light fixture to another junction box with
increasedamountofdaylight.
2. Setcontrolswitchto1,5,or20minutes.
Light comes on for no
apparentreason.
1. Lightcontrolmaybesensingsmallanimalsorauto-
mobiletrafc.
2. Rangeissettoohigh.
3. DualBrite®timerison.
1. Re-aimlightcontrol.
2. Reducerange.TurnRangeBoostoff.
3. Turn DualBrite®Timeroff.
Lightturnsofftoolatein
Dusk-to-Dawnsetting.
Lightcontrolmaybeinstalledinarelativelydarklocation. Relocatelightcontrol,oruse3hr.or6hr.setting.
Lightstaysoncontinu-
ously.
1. Alampispositionedtooclosetothelightcontrolor
pointedatnearbyobjectsthatcauseheattotrigger
thelightcontrol.
2. Thelightcontrolmaybepickingupaheatsource
likeanairvent,dryervent,orbrightlypainted,heat-
reectivesurface.
3. Lightcontrolisinmanualmode.
1. Repositionthelampawayfromthelightcontrolor
nearbyobjects.
2. Reducerange.Re-aimsensor.TurnRangeBoostoff.
3. SwitchlightcontroltoAUTO.
Lightashesonandoff. 1. Heatorlightfromthelampsmaybeturningthelight
controlonandoff.
2. Heatbeingreectedfromotherobjectsmaybeturn-
ingthelightcontrolonandoff.
3. LightcontrolisintheTESTmodeandwarmingup.
4. LightcontrolisinAlertFlashmode.
1. Repositionthelampsawayfromthelightcontrol.
2. Repositionlightcontrol.
3. Flashingisnormalundertheseconditions.
4. Flashingisnormalinthismode.SelectSecurityor
BulbSavermodetoturnashmodeoff.
Lightashesonce,then
stays off in manual
mode.
Lightcontrolisdetectingitsownlight. Repositionlampstokeepareabelowthelightcontrol
relativelydark.