Helmut Ruck Ruck UV & LED NAIL CURING DRYER User manual

WITH 18 LEDS AND ADJUSTABLE TIMER
Operating instructions | Revision 1 | Print
FÜR FUSS UND PFLEGE
RUCK®UV & LED NAIL CURING DRYER
GB
REF 41244

FÜR FUSS UND PFLEGE FÜR FUSS UND PFLEGE
3
|
2|
Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1 Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1
TABLE OF CONTENTS
Copyright
© 2016 HELLMUT RUCK GmbH. All rights reserved. This document must not be copied,
edited, reproduced or translated without the prior written permission of HELLMUT RUCK
GmbH.
HELLMUT RUCK GmbH | Daimlerstrasse 23 | D - 75305 Neuenbürg, Germany
web www.hellmut-ruck.de | tel. +49 (0)7082. 944 20 | fax +49 (0)7082. 944 22 22
1. www.hellmut-ruck.de
2. 41244
3. DOWNLOADS 41244 41244_Gebrauchsanweisung_Lichthärtungsgerät_DE.pdf
Congratulations on the purchase of your RUCK®UV & LED nail curing dryer.
An easy-to-use device for fast drying of UV and LED gels (not suitable for drying ordinary nail
polishes!). Can be used for fingernails and toenails, with five nails being able to be dried at
once (due to the open arch shape).
In order to use all settings optimally, please read these operating instructions.
Kind regards, HELLMUT RUCK GmbH
Page
TABLE OF CONTENTS 3
GENERAL INFORMATION, SCOPE OF DELIVERY 4
Description of the device 4
PRODUCT OVERVIEW 5
Unpacking the device 5
Obligations of the operator / personnel 5
SAFETY 5
Intended use 5
Symbols key 5
Safety notices 6
Scope of utilisation and extent of liability 6
Operational voltage 6
Suspicion of possible impact on safety 6
Eye protection 7
SAFETY, MAINTENANCE, DISPOSAL 7
OPERATION 8
Operating instructions 8
Technical features 8
Caution / Attention 9
RUCK®UV & LED NAIL CURING DRYER
YEARS
WARRANTY
QUALITY
SINCE MORE THAN
YEARS
distributed by

FÜR FUSS UND PFLEGE FÜR FUSS UND PFLEGE
5
|
4|
Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1 Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1
UNPACKING THE DEVICE
On receipt, please check the packaging and all parts supplied for possible damage during
transport.
If there is damage, please contact HELLMUT RUCK GmbH immediately. Please check that
the delivery is complete.
OBLIGATIONS OF THE OPERATOR
The operator of the device is obliged to only allow persons to work with the device who:
• are familiar with the regulations concerning occupational safety and accident prevention
and have been instructed in the application and handling of the device
• have read and understood the safety notices and the operating instructions
• have been informed of the applicable accident prevention guidelines
PERSONNEL OBLIGATIONS
Persons who work on the device are obligated:
• to read the safety notices and operating instructions before starting work and confirm with
their signature that they have understood both
• to observe the basic work safety guidelines before starting and during the work
INTENDED USE
The RUCK® LED nail curing dryer is designed exclusively for curing (polymerisation)
of light-curing nail polymers which can be cured when exposed to light in the
wavelength range of approx. 395 to 405 nm.
SCOPE OF DELIVERY
Check that the delivery is complete.
1 x RUCK®LED nail curing dryer
1 x power supply
1 x instructions
DEVICE DESCRIPTION
1 infrared induction / sensor function
2 digital display
3 timer function 30s
4 timer function 60s
5 timer function 90s
6 power connection
Illuminated LED display to indicate the remaining time / digital countdown.
Automatic switching on and off of the LED light as soon as the hand or foot is placed or
removed from under the device. Adjustable timer for 30s / 60s / 90s at the touch of a button.
PRODUCT OVERVIEWGENERAL INFORMATION, SCOPE OF DELIVERY
SAFETY
DECLARATION RELATING TO THESE OPERATING INSTRUCTIONS
Hellmut Ruck GmbH reserves all rights to modify and supplement these operating instruc-
tions. Hellmut Ruck GmbH has taken great care to keep these instructions free of inaccura-
cies and omissions. Please contact us if you find mistakes or inaccuracies. However, Hellmut
Ruck GmbH assumes no liability for mistakes in these operating instructions or consequential
damage resulting from the provision of these operating instructions or their application when
using the product.
These operating instructions must not be disseminated or supplemented without the express
approval of Hellmut Ruck GmbH.
SYMBOLS USED
This symbol identifies a potential point of danger for people or for the device
itself. It must be taken note of.
2
3
45
1
6

FÜR FUSS UND PFLEGE FÜR FUSS UND PFLEGE
7
|
6|
Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1 Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1
SAFETY NOTICES
The RUCK® LED nail curing dryer has left the factory in a technically perfect condition. The in-
structions in these operating instructions must always be observed in order to maintain this condi-
tion and enable safe operation. In order to avoid damage or danger to users and third parties, the
following safety notices must be observed.
For materials that do not cure when irradiated with light within the wavelength range of 395 to 405
nm. For products for which this is not clear, the respective material manufacturer should be consult-
ed.
SCOPE OF UTILISATION AND EXTENT OF LIABILITY
The device may only be used for its intended purpose. Any other use shall be regarded as improp-
er. The manufacturer accepts no liability for damage resulting from improper use or handling. The
user is obliged to check the device on their own responsibility for suitability and usability for the
intended purpose before use.
Only original spare parts and accessories from HELLMUT RUCK GmbH may be used. The manu-
facturer assumes no liability for damage resulting from the use of other spare parts or accessories.
OPERATIONAL VOLTAGE
Before using the unit, make sure that the voltage indicated on the nameplate corresponds to that of
the mains supply and that the unit is at room temperature.
SUSPICION OF POSSIBLE IMPACT ON SAFETY
If there is a suspicion that the device cannot be operated safely, it must be disconnected from the
mains supply, that is, the mains cable must be disconnected from the socket.
The device must be secured against unintentional operation.
SAFETYSAFETY
EYE PROTECTION
Avoid indirect or even direct irradiation of the eyes. Prolonged irradiation of the eyes can cause an
unpleasant sensation and possibly even damage the eyes. Persons who are generally sensitive to
light, photoallergic, on medication for photosensitivity or taking photosensitising medication should
not be exposed to the light from the device.
Persons who work with the device or are irradiated with the device should always wear protective
glasses that absorb light below 500 nm – especially if they have undergone eye surgery.
MAINTENANCE, CLEANING
Maintenance work may only be carried out by HELLMUT RUCK GmbH specialists or by electri-
cians. During cleaning, no liquids or other foreign materials may come into contact with the electri-
cal components. The mains plug must be disconnected during cleaning. Do not store the device
outdoors and always keep it in a dry place.
DISPOSAL
Unserviceable equipment must be disposed of in accordance with the relevant
national regulations.
MAINTENANCE, CLEANING, DISPOSAL

FÜR FUSS UND PFLEGE FÜR FUSS UND PFLEGE
9
|
8|
Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1 Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1
OPERATING INSTRUCTIONS
Remove the device from the box, remove the packaging material and, if necessary, remove the
transport lock. Place the device on the worktable.
Before using the device for the first time, you should ensure that mains power char-
acteristics match the values quoted on the nameplate. The device and mains cable
should not be damaged.
1. Connect the power supply; the display lights up automatically.
2. The infrared sensor starts automatically when a hand/foot is placed in the device and
switches off automatically when the hand/foot is removed.
Preset maximum running time is 99 seconds.
Or select the appropriate timer setting: 30s, 60s, 90s. Press the timer a second time and
the lamp switches on.
At the end of the process (signalled by the timer), the lamp switches off automatically.
3. After using the device, disconnect the power supply or pull the plug.
TECHNICAL FEATURES
1. Number of LEDs: 18
2. Wattage: 24W
3. Timer: 30s, 60s, 90s
4. Volt/voltage: 100–240V, 50/60Hz
Output: DC 24V – 1A
5. Wavelength: 365 + 405nm
6. Dimensions: 210x120x80mm
We reserve the right to make technical changes without prior notice.
CAUTION/ATTENTION
• Please read the operating instructions carefully before using the device.
• Use the device only according to our specifications.
• Do not allow the unit to come into contact with water, because this could damage it.
• Do not use the device for more than 600 minutes at a time or the service life of the device
could be shortened.
• Switch off the unit if you notice unusual signs such as smoke or unpleasant odours.
• Keep the device clean, and keep it away from children.
• Do not use the device with a defective power supply.
• The device should not be used if the timer is defective.
IF THESE INSTRUCTIONS ARE NOT HEEDED, THE GUARANTEE WILL LAPSE AND WE
CANNOT ACCEPT LIABILITY!
8|OPERATION OPERATION

FÜR FUSS UND PFLEGE FÜR FUSS UND PFLEGE
11
|
10|
Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1 Operating Instructions for RUCK®LED Nail Curing Dryer | Revision 1
NOTES NOTES

HELLMUT RUCK GmbH
Daimlerstrasse 23
D-75305 Neuenbürg, Germany
tel +49 (0)7082. 944 20
fax +49 (0)7082. 944 22 22
E-mail contact@hellmut-ruck.de
web www.hellmut-ruck.de
Rebune Int‘l Co., Ltd
Guangzhou P.R.China
Tel: 0086 - 20 - 86679717
Cel: 0086 - 15920451241
Fax: 0086 - 20 - 86679716
Web: www.rebunehk.com
distributed by
Table of contents
Popular Personal Care Product manuals by other brands

Pacific Supply
Pacific Supply Ortop AFO manual

mdpen
mdpen MicroNeedling user manual

sensiplast
sensiplast Lumbo-Active Instructions for use

Raritan
Raritan SeaEra Toilets Operation and installation instructions

Ruck
Ruck 41134 Manual instruction

Current Solutions
Current Solutions InTENSity Select Combo instruction manual