Themodels may be powered at 240V or208V.
This cooktop does not require a neutral connection. If
the cooktop is to be completely enclosed in a cabinet,
feed the cooktop cable through the opening in the
cabinet. Make the electrical connection following the
appropriate steps for your installation.
Your cooktop must be connected to the proper
electrical voltage and frequency as specified in the
table on the right.
Location of serial tag
The flexible conduit (supplied) 3 feet long (100 cm)
located at the right rear of the cooktop bottom box
should be connected directly into a junction box. Do
not cut the conduit. A U.L - or CSA - listed conduit
connector must be provided at each end of the power
supply cable (at the cooktop and at the junction box.)
A time delay fuse or circuit breaker is recommended.
Do not ground to a gas pipe. Do not have a fuse in the
grounding or neutral circuit.
Fuse both supply (phase) lines.
Improper connection of aluminum house wiring to the
copper leads can result in a serious problem such as an
electrical fire.
Model Power Supply
240 V 60 Hz 208 V 60 Hz Approval
code
30”KIC30 7.2 kW 30A 6.45 kW 31A 815T40*T
36”KIC36 10.8 kW 45A 9.4 kW 45A 815V50*U
National Fire Protection Association Batterymarch
Park, Quincy, Massachusetts 02169-7471
A three-wire, single phase, 240 Volt 60 cycle electrical
system (properly circuit protected to meet Local
Codes of NFPA No.70) must be provided. Unit must
be properly grounded in accordance with local wiring
code. The chart below recommends the minimum
circuit protector and wire size if the appliance is the
only unit on the circuit. If smaller sizes of wire are
used, the unit efficiency will be reduced and a fire
hazard may be created. It is advisable that the electrical
wiring and hookup be accomplished by a competent
electrician.
Amperes
kW Rating on
serial plate
Wire size
(AWG)
0-4.8 20 12
4.9-6.9 30 10
7.0-9.9 40 8
10.0-11.9 50 8
12.0-14.9 60 6
Be sure your appliance is properly installed and
grounded by a qualified technician. Ask your dealer to
recommend a qualified technician or an authorized
repair service. This cooktop does not require a neutral
connection. If the cooktop is to be completely
enclosed in a cabinet, feed the cooktop cable through
the opening in the cabinet. Make the electrical
connection following the appropriate steps for your
installation.
Recommended Minimum Circuit protection
NOTICE
NOTICE
ELECTRICAL CONNECTIONS