Hikmicro G Series User manual

Handheld Thermography Camera
User Manual

Handheld Thermography Camera User Manual
i
Legal Information
© 2021 Hangzhou Microimage Software Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and
all other information hereinafter are for description and explanation only. The information
contained in the Manual is subject to change, without notice, due to firmware updates or other
reasons. Please find the latest version of this Manual at the HIKMICRO website
(http://www.hikmicrotech.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the
Product.
Trademarks
and other HIKMICRO's trademarks and logos are the properties of
HIKMICRO in various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND
“WITH ALL FAULTS AND ERRORS”. HIKMICRO MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR
A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT
WILL HIKMICRO BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION,
WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT
LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKMICRO
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF INTERNET PROVIDES FOR INHERENT SECURITY RISKS,
AND HIKMICRO SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY
LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS
INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKMICRO WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.
YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE

Handheld Thermography Camera User Manual
ii
DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED
TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN
RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER
PREVAILS.

Handheld Thermography Camera User Manual
iii
Regulatory Information
FCC Information
Please take attention that changes or modification not expressly approved by the party
responsible for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
—Consult the dealer or an experienced radio/TV techniciaan for help
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause
undesired operation.
EU Conformity Statement
This product and - if applicable - the supplied accessories too are marked with
"CE" and comply therefore with the applicable harmonized European standards
listed under the EMC Directive 2014/30/EU, the RoHS Directive 2011/65/EU
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points. For
more information see: www.recyclethis.info.

Handheld Thermography Camera User Manual
iv
2006/66/EC (battery directive): This product contains a battery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentation for specific battery information. The battery is marked with this
symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the battery to your supplier or to a
designated collection point. For more information see:www.recyclethis.info.
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
1. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is
subject to the following two conditions: this device may not cause interference, and
2. this device must accept any interference, including interference that may cause undesired
operation of the device.
1. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radioexempts de licence. L'exploitation est autorisée aux deux conditions suivantes : l'appareil
ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour
l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la
puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à
l'établissement d'une communication satisfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the
radiator and your body.
Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur et
votre corps.

Handheld Thermography Camera User Manual
v
Symbol Conventions
The symbols that may be found in this document are defined as follows.
Symbol
Description
Danger
Indicates a hazardous situation which, if not avoided, will or could
result in death or serious injury.
Caution
Indicates a potentially hazardous situation which, if not avoided,
could result in equipment damage, data loss, performance
degradation, or unexpected results.
Note
Provides additional information to emphasize or supplement
important points of the main text.

Handheld Thermography Camera User Manual
vi
Safety Instruction
These instructions are intended to ensure that user can use the product correctly to avoid danger
or property loss.
Laws and Regulations
●Use of the product must be in strict compliance with the local electrical safety regulations.
Transportation
●Keep the device in original or similar packaging while transporting it.
●Keep all wrappers after unpacking them for future use. In case of any failure occurred, you need
to return the device to the factory with the original wrapper. Transportation without the
original wrapper may result in damage on the device and the company shall not take any
responsibilities.
●DO NOT drop the product or subject it to physical shock. Keep the device away from magnetic
interference.
Power Supply
●Please purchase the charger by yourself. Input voltage should meet the Limited Power Source (5
VDC, 940 mA) according to the IEC61010-1 standard. Please refer to technical specifications for
detailed information.
●Make sure the plug is properly connected to the power socket.
●DO NOT connect multiple devices to one power adapter, to avoid over-heating or fire hazards
caused by overload.
Battery
●The built-in battery cannot be dismantled. Please contact the manufacture for repair if
necessary.
●DO NOT charge other battery types with the supplied charger. Confirm there is no flammable
material within 2 m of the charger during charging.
●For long-term storage of the battery, make sure it is fully charged every half year to ensure the
battery quality. Otherwise, damage may occur.
●DO NOT place the battery near heating or fire source. Avoid direct sunlight.
●DO NOT swallow the battery to avoid chemical burns.
●DO NOT place the battery in the reach of children.
●The battery voltage is 3.6 V, and the battery capacity is 6700 mAh.
●The battery is certified by UL2054.
Maintenance
●If the product does not work properly, please contact your dealer or the nearest service center.
We shall not assume any responsibility for problems caused by unauthorized repair or
maintenance.
●A few device components (e.g., electrolytic capacitor) require regular replacement. The average

Handheld Thermography Camera User Manual
vii
lifespan varies, so periodic checking is recommended. Contact your dealer for details.
●Wipe the device gently with a clean cloth and a small quantity of ethanol, if necessary.
●If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the device may be impaired.
Using Environment
●DO NOT expose the device to extremely hot, cold, dusty, corrosive, saline-alkali, or damp
environments. Make sure the running environment meets the requirement of the device. The
operating temperature shall be -20 °C to 50 °C (-4 °F to 122 °F), and the operating humidity shall
be 90% or less.
●This device can only be safely used in the region below 2000 meters above the sea level.
●Place the device in a dry and well-ventilated environment.
●DO NOT expose the device to high electromagnetic radiation or dusty environments.
●DO NOT aim the lens at the sun or any other bright light.
●When any laser equipment is in use, make sure that the device lens is not exposed to the laser
beam, or it may burn out.
●The device is suitable for indoor and outdoor uses, but do not expose it in wet conditions.
●The level of protection is IP 54.
●The pollution degree is 2.
Emergency
●If smoke, odor, or noise arises from the device, immediately turn off the power, unplug the
power cable, and contact the service center.
Laser Light Supplement Warning
Warning: The laser radiation emitted from the device can cause eye injuries, burning of skin or
inflammable substances. Prevent eyes from direct laser. Before enabling the Light Supplement
function, make sure no human or inflammable substances are in front of the laser lens. The laser
meets the IEC60825-1:2014 standard.
Laser maintenance: It is not necessary to maintain the laser regularly. If the laser does not work,
the laser assembly needs to be replaced in the factory under warranty. Keep the device power off
when replacing laser assembly. Caution-Use of controls or adjustments or performance of
procedures other than those specified herein may result in hazardous radiation exposure.
Manufacture Address
Room 313, Unit B, Building 2, 399 Danfeng Road, Xixing Subdistrict,Binjiang District, Hangzhou,
Zhejiang 310052, China
Hangzhou Microimage Software Co., Ltd.

Handheld Thermography Camera User Manual
viii
Contents
Chapter 1 Overview....................................................................................................................1
1.1 Device Description.................................................................................................................1
1.2 Main Function........................................................................................................................1
1.3 Appearance............................................................................................................................2
Chapter 2 Preparation................................................................................................................5
2.1 Charge Device........................................................................................................................5
2.1.1 Charge Device via Charging Base...............................................................................5
2.1.2 Charge Device via Cable Interface .............................................................................6
2.2 Mount Hand Strap.................................................................................................................6
2.3 Mount Protective Cover........................................................................................................7
2.4 Mount Teleconverter ............................................................................................................8
2.5 Power On/Off ......................................................................................................................10
2.5.1 Set Auto Power-off Duration...................................................................................10
2.6 Operation Method ..............................................................................................................10
2.7 Menu Description................................................................................................................11
Chapter 3 Display Settings........................................................................................................12
3.1 Focus ....................................................................................................................................12
3.1.1 Focus Lens.................................................................................................................12
3.1.2 Laser Auxiliary Focus................................................................................................12
3.1.3 Semi-auto Focus .......................................................................................................13
3.1.4 Autofocus..................................................................................................................13
3.2 Set Screen Brightness..........................................................................................................13
3.3 Set Display Mode.................................................................................................................14
3.4 Set Palettes..........................................................................................................................14
3.5 Adjust Digital Zoom.............................................................................................................15
3.6 Display OSD Info..................................................................................................................15
Chapter 4 Temperature Measurement......................................................................................16
4.1 Set Thermography Parameters...........................................................................................16
4.1.1 Set Unit.....................................................................................................................17

Handheld Thermography Camera User Manual
ix
4.2 Set Temperature Range ......................................................................................................17
4.3 Set Thermography Rule.......................................................................................................17
4.3.1 Set Point Rule ...........................................................................................................18
4.3.2 Set Line Rule .............................................................................................................18
4.3.3 Set Frame Rule..........................................................................................................19
4.3.4 Delete Rules..............................................................................................................19
4.4 Set Temperature Alarm.......................................................................................................19
Chapter 5 Picture and Video.....................................................................................................21
5.1 Capture Picture....................................................................................................................21
5.2 Scan QR Code.......................................................................................................................22
5.3 Record Video .......................................................................................................................22
5.4 View Recorded Files ............................................................................................................23
5.5 Export Files ..........................................................................................................................24
Chapter 6 Distance Detection ...................................................................................................25
Chapter 7 Connect Bluetooth ...................................................................................................26
Chapter 8 Set LED Light ............................................................................................................27
Chapter 9 Thermal View APP Connection..................................................................................28
9.1 Connect via Wi-Fi.................................................................................................................28
9.2 Connect via Hot Spot...........................................................................................................29
Chapter 10 Maintenance ..........................................................................................................30
10.1 View Device Information ..................................................................................................30
10.2 Set Date and Time .............................................................................................................30
10.3 Upgrade Device .................................................................................................................30
10.4 Restore Device...................................................................................................................30
Chapter 11 Appendix................................................................................................................31
11.1 Common Material Emissivity Reference ..........................................................................31

Handheld Thermography Camera User Manual
1
Chapter 1 Overview
1.1 Device Description
The handheld thermography camera is a device with both optical images and thermal images. It
can do thermography, distance measurement, video recording, snapshot capturing, alarm, and it
can connect to Wi-Fi, hotspot and Bluetooth. The built-in high-sensitivity IR detector and high-
performance sensor detects the variation of temperature and measure the real-time temperature.
The built-in laser module detects the target distance.
The device is easy to use, and adopts ergonomic design. It is widely applied to substations,
electricity prevention detection of companies, and reconnaissance survey of construction field.
1.2 Main Function
Thermography
Device detects the real-time temperature, and display it on the screen.
Distance Measurement
Device can detect the target distance with the laser light.
Fusion
Device can display fusion of thermal view and optical view.
QR Code
Device can scan the QR code and capture it.
Palette and Alarm
Device supports multiple palettes, and you can set the palette mode according to the alarm
function.
Client Software Connection
You can connect the device with client software via Wi-Fi or hot spot. Then you can view live view,
capture, and recording, etc. on your phone.
Bluetooth
Device can be connected to headset via Bluetooth, and you can hear the voice in the recording or
capture.

Handheld Thermography Camera User Manual
2
1.3 Appearance
Figure 1-1 Appearance

Handheld Thermography Camera User Manual
3
Table 1-1 Interface Description
Component
Function
Laser Button
Hold the button to turn on laser, and release the button to turn off laser.
Navigation
Button
Menu Mode:
●Press , , and to select parameters.
●Press to confirm.
Non-Menu Mode:
●Press to turn on/off the LED light supplement.
●Press to start digital zoom.
Lens Sheet
Button
Cover the lens to perform the correction.
Back Button
Exit the menu or return to previous menu.
Focus Knob
Adjust lens focal length. Refer toFocus Lens.
Trigger
Pull the trigger to capture or scan the QR code. Hold the trigger to record
videos.

Handheld Thermography Camera User Manual
4
Component
Function
Autofocus
Pull the trigger to turn on/off autofocus function.
Caution
The laser radiation emitted from the device can cause eye injuries, burning of skin or inflammable
substances. Prevent eyes from direct laser. Before enabling the Light Supplement function, make
sure no human or inflammable substances are in front of the laser lens. The laser meets the
IEC60825-1:2014 standard.

Handheld Thermography Camera User Manual
5
Chapter 2 Preparation
2.1 Charge Device
2.1.1 Charge Device via Charging Base
Steps
Note
Please charge the device with the cable and power adapter supplied by the manufacturer (or
according to the input voltage from the specifications).
1. Hold the device, and press both battery lock catches of the device.
Figure 2-1 Remove Battery Base
2. Hold the lock catches, and draw the battery base to take out the battery.
3. Insert the battery into the charging base. You can see the charging status via the pilot lamp on
the charging base.
Figure 2-2 Charge Battery
4. When the battery is fully charged, draw the battery from the charging base.
5. Insert battery into the device.

Handheld Thermography Camera User Manual
6
2.1.2 Charge Device via Cable Interface
Before You Start
Please make sure the battery is installed before charging.
Steps
1. Open the top cover of the device.
2. Connect the interface and the power adaptor with Type-C or USB cable.
2.2 Mount Hand Strap
The upper part of the hand strap is attached to the camera by a buckle. There are two buckles on
both sides of the camera. The lower part of the hand strap is threaded through the hole at the
base of the camera.
Steps
1. Insert the upper part of the hand strap into the buckle.
Figure 2-3 Insert Upper Part of Hand Strap
2. Fit the buckle on the device and tighten the screw with the supplied wrench.
3. Thread the lower part of the hand strap through the hole at the base of the device. Secure the
hand strap with the hook-and-loop fastener.

Handheld Thermography Camera User Manual
7
Figure 2-4 Secure Lower Part of Hand Strap
2.3 Mount Protective Cover
Attach the protective cover when the device is not in use.
Steps
1. Align the threaded hole of the device with the mounting hole of the lens cover.
2. Insert the screw, and rotate it clockwise to fix the lens cover.
Figure 2-5 Fix Protective Cover

Handheld Thermography Camera User Manual
8
2.4 Mount Teleconverter
Before You Start
Purchase the teleconverter separately by yourself.
Steps
1. Turn the decorative ring 38 degree anticlockwise.
Figure 2-6 Rotate the Decorative Ring
2. Remove the decorative ring.

Handheld Thermography Camera User Manual
9
Figure 2-7 Remove the Decorative Ring
3. Align the two red spots on the teleconverter and the device, then rotate the teleconverter
clockwise to finish mounting.
Figure 2-8 Align the Red Spots
4. Rotate the teleconverter clockwise to fix it.
Figure 2-9 Mount the Teleconverter
5. Optional: Rotate the teleconverter anticlockwise to dismount it.

Handheld Thermography Camera User Manual
10
Figure 2-10 Dismount the Teleconverter
2.5 Power On/Off
Power On
Remove the lens cover, and hold for over three seconds to turn on the device. You can
observe the target when the interface of the device is stable.
Note
It may take at least 30 s until the device is ready for using when you power on it.
Power Off
When the device is turned on, hold for three seconds to power off the device.
2.5.1 Set Auto Power-off Duration
Go to Local Settings → Device Settings → Auto Power-off Duration Settings to set the
automatic shutdown time for device as required.
2.6 Operation Method
The device supports both touch-screen control and button control.
Touch-screen control
Tap on the screen to set parameters and configurations.
Other manuals for G Series
3
This manual suits for next models
3
Table of contents
Other Hikmicro Digital Camera manuals

Hikmicro
Hikmicro GH25L User manual

Hikmicro
Hikmicro HM-TP21-6VF_W-M10 User manual

Hikmicro
Hikmicro Pocket Series User manual

Hikmicro
Hikmicro HIKMICRO SP Series User manual

Hikmicro
Hikmicro HIKMICRO SP Series User manual

Hikmicro
Hikmicro M Series User manual

Hikmicro
Hikmicro E1L User manual

Hikmicro
Hikmicro SP60H User manual

Hikmicro
Hikmicro B Series User manual

Hikmicro
Hikmicro HIKMICRO SP Series User manual